Wei Wei

Dr. Wei Wei

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SCShengli Chen
Shengli Chen
XZXiaobing Zheng
Xiaobing Zheng
XLXin Li
Xin Li
WWWei Wei
Wei Wei
SDShenda Du
Shenda Du
FGFuxiang Guo
Fuxiang Guo
To calibrate the low signal response of the ocean color (OC) bands and test the stability of the Fengyun-3D (FY-3D)/Medium Resolution Spectral Imager II (MERSI-II), an absolute radiometric calibration field test of FY-3D/MERSI-II at the Lake Qinghai Radiometric Calibration Site (RCS) was carried out in August 2018. The lake surface and atmospheric parameters were mainly measured by advanced observation instruments, and the MODerate spectral resolution atmospheric TRANsmittance algorithm and computer model (MODTRAN4.0) was used to simulate the multiple scattering radiance value at the altitude of the sensor. The results showed that the relative deviations between bands 9 and 12 are within 5.0%, while the relative deviations of bands 8, and 13 are 17.1%, and 12.0%, respectively. The precision of the calibration method was verified by calibrating the Aqua/Moderate-resolution Imaging Spectroradiometer (MODIS) and National Polar-orbiting Partnership (NPP)/Visible Infrared Imaging Radiometer (VIIRS), and the deviation of the calibration results was evaluated with the results of the Dunhuang RCS calibration and lunar calibration. The results showed that the relative deviations of NPP/VIIRS were within 7.0%, and the relative deviations of Aqua/MODIS were within 4.1% from 400 nm to 600 nm. The comparisons of three on-orbit calibration methods indicated that band 8 exhibited a large attenuation after launch and the calibration results had good consistency at the other bands except for band 13. The uncertainty value of the whole calibration system was approximately 6.3%, and the uncertainty brought by the field surface measurement reached 5.4%, which might be the main reason for the relatively large deviation of band 13. This study verifies the feasibility of the vicarious calibration method at the Lake Qinghai RCS and provides the basis and reference for the subsequent on-orbit calibration of FY-3D/MERSI-II.

16 April 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
FGFuxiang Guo
Fuxiang Guo
XZXiaobing Zheng
Xiaobing Zheng
YZYanna Zhang
Yanna Zhang
WWWei Wei
Wei Wei
ZZZejie Zhang
Zejie Zhang
XLXin Li
Xin Li
Reference targets with stability, uniformity, and known reflectance on the Earth’s surface, such as deserts, can be used for the absolute radiometric calibration of satellite sensors. A wide-angle hyperspectral reflectance model at the top of atmosphere (TOA) over such a reference target will expand the applicability of on-orbit calibration to different spectral bands and angles. To achieve the long-term, continuous, and high-precision absolute radiometric calibration of remote sensors, a wide-angle hyperspectral TOA reflectance model of the Libyan Desert was constructed based on spectral reflectance data, satellite overpass parameters, and atmospheric parameters from the Terra/Aqua and Earth Observation-1 (EO-1) satellites between 2003 and 2012. By means of angle fitting, viewing angle grouping, and spectral extension, the model is applicable for absolute radiometric calibration of the visible to short-wave infrared (SWIR) bands for sensors within viewing zenith angles of 65 degrees. To validate the accuracy and precision of the model, a total of 3120 long-term validations of model accuracy and 949 cross-validations with the Landsat 8 Operational Land Imager (OLI) and Suomi National Polar-Orbiting Partnership (NPP) Visible Infrared Imaging Radiometer Suite (VIIRS) satellite sensors between 2013 and 2020 were conducted. The results show that the TOA reflectance calculated by the model had a standard deviation (SD) of relative differences below 1.9% and a root-mean-square error (RMSE) below 0.8% when compared with observations from the Moderate Resolution Imaging Spectroradiometer (MODIS) and Landsat 8 OLI. The SD of the relative differences and the RMSE were within 2.7% when predicting VIIRS data.

15 November 2024 in Photonics
Verified
Journal Article
Open access
PDF file
鑫王鑫蕊 王
鑫蕊 王
XLXin Li
Xin Li
QZQuan ZHANG
Quan ZHANG
YSYuanjian Shi
Yuanjian Shi
WWWei Wei
Wei Wei
ELEnchao Liu
Enchao Liu
Presently, on-orbit calibration methods have several problems, such as low calibration accuracy and broken traceability links, so an urgent need exists to unify traceable and high-precision on-orbit radiometric calibration loads as benchmarks for cross-transfer radiometric calibration. Considering the deficiencies of current on-orbit calibration, this paper proposes adjusting the size of the variable diaphragm at the entrance pupil and the integration time to attain large dynamic attenuation, converting the radiometric calibration into absolute geometric calibration of the attenuation device, and realizing a self-calibrating real entrance pupil imaging spectrometer (SCREPIS) that can be directly used to view the Earth and the Sun and quickly obtain apparent reflectance data. An initial structural design method based on the distance between individual mirrors is proposed according to the instrument design requirements. The design of a real entry pupil image-side telecentricity off-axis three-reflector front optical system with a 7° field of view along the slit direction, a 3.7 systematic F-number, and a 93 mm focal length is finally realized, and the system image plane energy is verified to change proportionally to the variable diaphragm area. Finally, the front system and rear Offner optical system are jointly simulated and optically designed. The system provides instrumental support for cross-calibration and theoretical support and a technical basis for planning space-based radiation references.

14 May 2025 in Photonics
Verified
Journal Article
Open access
PDF file
鑫王鑫蕊 王
鑫蕊 王
XLXin Li
Xin Li
QZQuan ZHANG
Quan ZHANG
WWWei Wei
Wei Wei
ELEnchao Liu
Enchao Liu
At present, off-axis three-mirror optical systems mostly adopt aspherical mirrors with small apertures and small F/# to meet the development requirements of remote sensing payloads towards high precision, small volume, and lightweight design. However, current references rarely provide the derivation, design, and detection of the testing light path for aspherical mirrors with small apertures and small F/#. Aiming at the existing gap, this paper proposes a method of decomposing the compensation optical path into two imaging light paths and derives the initial structure of the compensation optical path. Furthermore, specific solutions are proposed from two aspects: the design of the null compensator and the establishment of the testing light path. Finally, the compensation optical path design and detection are carried out for the primary mirror and the tertiary mirror of the self-calibrating real entrance pupil imaging spectrometer, guiding the completion of the system processing, assembly, and adjustment. The detection results show that the RMS of the surface shapes of the primary mirror and the tertiary mirror is 1/40λ (λ = 633 nm). This derivation method and the design method of the initial optical path have the characteristics of simple calculation, rapid optimization, and universal applicability, and are applicable to the detection of all quadratic concave surfaces.

1 February 2023 in Optica Open
Verified
Preprint
Open access
PDF file
WWWei Wei
Wei Wei
XLXin Li
Xin Li
YSYuanjian Shi
Yuanjian Shi
YZYunxiang Zhang
Yunxiang Zhang
To meet the needs of the on-orbit radiometric calibration of remote sensors, an thermal infrared channel field radiometer (TICFR) was developed for on-site measurement. The working principle, optical system design and mechanical structure design of the TICFR were established. Radiometric calibration and calibration uncertainty analysis of the TICFR laboratory were performed. The results show that the received radiance of each TICFR channel has a strong linear relationship with the DN response value. TICFR thermal shock resistance and working environment temperature adaptability experiments were performed. The results show that the TICFR displays strong thermal shock resistance and can be applied in working environments from -20°C to 50°C. To verify the accuracy of the TICFR measurement data and the reliability of the instrument, a field comparison experiment of the TICFR and CE312 was performed at the National High-Resolution Remote Sensing Comprehensive Calibration Field. The results show that the surface brightness temperatures measured by the two devices display the same trend. The average brightness temperature deviation measured by the corresponding channels of the two instruments is less than 0.1K, and the standard deviation is less than 0.3 K; these results confirm that the measurement accuracy and stability of the TICFR are similar to those of the CE312. The TICFR has important applications in remote sensing thermal infrared band site calibration.

1 February 2023 in Optica Open
Verified
Preprint
Open access
PDF file
WWWei Wei
Wei Wei
XLXin Li
Xin Li
YSYuanjian Shi
Yuanjian Shi
YZYunxiang Zhang
Yunxiang Zhang
To meet the needs of the on-orbit radiometric calibration of remote sensors, an thermal infrared channel field radiometer (TICFR) was developed for on-site measurement. The working principle, optical system design and mechanical structure design of the TICFR were established. Radiometric calibration and calibration uncertainty analysis of the TICFR laboratory were performed. The results show that the received radiance of each TICFR channel has a strong linear relationship with the DN response value. TICFR thermal shock resistance and working environment temperature adaptability experiments were performed. The results show that the TICFR displays strong thermal shock resistance and can be applied in working environments from -20°C to 50°C. To verify the accuracy of the TICFR measurement data and the reliability of the instrument, a field comparison experiment of the TICFR and CE312 was performed at the National High-Resolution Remote Sensing Comprehensive Calibration Field. The results show that the surface brightness temperatures measured by the two devices display the same trend. The average brightness temperature deviation measured by the corresponding channels of the two instruments is less than 0.1K, and the standard deviation is less than 0.3 K; these results confirm that the measurement accuracy and stability of the TICFR are similar to those of the CE312. The TICFR has important applications in remote sensing thermal infrared band site calibration.