Shengli Chen

Dr. Shengli Chen

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SCShengli Chen
Shengli Chen
XZXiaobing Zheng
Xiaobing Zheng
XLXin Li
Xin Li
WWWei Wei
Wei Wei
SDShenda Du
Shenda Du
FGFuxiang Guo
Fuxiang Guo
To calibrate the low signal response of the ocean color (OC) bands and test the stability of the Fengyun-3D (FY-3D)/Medium Resolution Spectral Imager II (MERSI-II), an absolute radiometric calibration field test of FY-3D/MERSI-II at the Lake Qinghai Radiometric Calibration Site (RCS) was carried out in August 2018. The lake surface and atmospheric parameters were mainly measured by advanced observation instruments, and the MODerate spectral resolution atmospheric TRANsmittance algorithm and computer model (MODTRAN4.0) was used to simulate the multiple scattering radiance value at the altitude of the sensor. The results showed that the relative deviations between bands 9 and 12 are within 5.0%, while the relative deviations of bands 8, and 13 are 17.1%, and 12.0%, respectively. The precision of the calibration method was verified by calibrating the Aqua/Moderate-resolution Imaging Spectroradiometer (MODIS) and National Polar-orbiting Partnership (NPP)/Visible Infrared Imaging Radiometer (VIIRS), and the deviation of the calibration results was evaluated with the results of the Dunhuang RCS calibration and lunar calibration. The results showed that the relative deviations of NPP/VIIRS were within 7.0%, and the relative deviations of Aqua/MODIS were within 4.1% from 400 nm to 600 nm. The comparisons of three on-orbit calibration methods indicated that band 8 exhibited a large attenuation after launch and the calibration results had good consistency at the other bands except for band 13. The uncertainty value of the whole calibration system was approximately 6.3%, and the uncertainty brought by the field surface measurement reached 5.4%, which might be the main reason for the relatively large deviation of band 13. This study verifies the feasibility of the vicarious calibration method at the Lake Qinghai RCS and provides the basis and reference for the subsequent on-orbit calibration of FY-3D/MERSI-II.

10 December 2025 in Electronics
Verified
Journal Article
Open access
PDF file
SCShengli Chen
Shengli Chen
LJLin Jiang
Lin Jiang
KBKeqiang Bai
Keqiang Bai
YCYuming Chen
Yuming Chen
XXXiaoang Xu
Xiaoang Xu
YLYueyue Liu
Yueyue Liu
Human–robot cooperative tasks require physical human–robot interaction (pHRI) systems that can adapt to individual human behaviors while ensuring robustness and stability. This paper presents a dual-loop control framework combining an admittance outer loop and a neural adaptive inner loop based on the Robust Integral of the Sign of the Error (RISE) approach. The outer loop reshapes the manipulator trajectory according to interaction forces, ensuring compliant motion and user safety. The inner-loop Adaptive RISE–RBFNN controller compensates for unknown nonlinear dynamics and bounded disturbances through online neural learning and robust sign-based correction, guaranteeing semi-global asymptotic convergence. Quantitative results demonstrate that the proposed adaptive RISE controller with neural-network error compensation (ARINNSE) achieves superior performance in the Joint-1 tracking task, reducing the root-mean-square tracking error by approximately 51.7% and 42.3% compared to conventional sliding mode control and standard RISE methods, respectively, while attaining the smallest maximum absolute error and maintaining control energy consumption comparable to that of RISE. Under human–robot interaction scenarios, the controller preserves stable, bounded control inputs and rapid error convergence even under time-varying disturbances. These results confirm that the proposed admittance-based RISE–RBFNN framework provides enhanced robustness, adaptability, and compliance, making it a promising approach for safe and efficient human–robot collaboration.

6 August 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
YYYangshuo Yue
Yangshuo Yue
ZWZhao Weijie
Zhao Weijie
JWJiaxu Wang
Jiaxu Wang
ZYZelin Yu
Zelin Yu
ZZZhiheng Zha
Zhiheng Zha
XXXiaoang Xu
Xiaoang Xu
Conventional hip exoskeletons typically employ multiple actuators to provide effective assistance to the corresponding joint, leading to an increase in the weight of the exoskeleton. Underactuated designs reduce the number of actuators, thereby lowering system weight and cost. However, existing single-motor underactuated hip exoskeletons still face challenges in achieving precise assistance and accommodating non-walking movements such as free sitting. In this work, we propose an underactuated hip exoskeleton with a series elastic actuator (SEA) and two independent cables for walking assistance. The incorporation of the SEA contributes to system safety and precise assistive force control. Furthermore, the proposed differential cable structure enables free sitting movement and allows for non-strictly symmetric hip motion. In experiments, with a target assistive force of 300 N, the proposed actuator achieves a peak force-tracking accuracy of 98.01% in walking tests, and the hip exoskeleton reduces peak muscle activation by up to 23.62% during walking.

24 June 2026 in Biomimetics
Verified
Journal Article
Open access
PDF file
YZYou Zhang
You Zhang
YPYang Pan
Yang Pan
LWLingyu Wang
Lingyu Wang
HCHaoran Cui
Haoran Cui
SJSurong Jiang
Surong Jiang
BCBai Chen
Bai Chen
Structural static testing is paramount for validating the structural integrity of critical aerospace components. However, conventional test rigs are often constrained to fixed loading axes and frequently induce parasitic torques. Accurate reproduction of aero-engine pylon flight loads therefore requires a mechanism that combines omnidirectional vector loading, high stiffness, and efficient force transmission. Achieving these coupled requirements is primarily a geometric synthesis problem, yet the associated workspace, stiffness, and load–capacity indices are nonlinear, mutually coupled, and expensive to evaluate over dense pose samples. To address this optimization bottleneck, this work develops a task-specific 6-UPS loading mechanism and a bio-inspired sensitivity-weighted NSGA-II algorithm for its geometric synthesis. Inspired by gene/locus-specific heterogeneity in biological evolution, the algorithm assigns variable-wise search intensities according to design-variable sensitivities, which are estimated using Multivariate Adaptive Regression Splines (MARS). In this way, influential design genes receive stronger local exploitation, whereas less sensitive ones retain broader exploration. Numerical simulations demonstrate that the proposed approach reduces computation time from about 30 h to 3 h relative to direct optimization with the baseline NSGA-II, while simultaneously improving workspace, stiffness, and load-carrying capacity. A hybrid physical prototype was further tested under 240 loaded pose conditions; the system maintained force magnitude errors below 0.64% (63.42 N) and directional deviations below 1.15°. These results support the efficacy of the proposed bio-inspired optimization-based design methodology for high-fidelity static testing of aero-engine pylons under the adopted hybrid setup.

4 November 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
SCShengli Chen
Shengli Chen
YCYuming Chen
Yuming Chen
XXXiaoang Xu
Xiaoang Xu
JLJiahao Li
Jiahao Li
KYKe Ye
Ke Ye
TCTianzuo Chang
Tianzuo Chang
Self-supervised depth estimation methods enable the recovery of scene depth information from monocular endoscopic images, thereby assisting endoscopic navigation. However, existing monocular endoscopic depth estimation methods generally fail to capture the inherent continuity of depth in intestinal structures. To address this limitation, this work presents the Mono-ViM framework, a CNN-Mamba hybrid architecture that enhances depth estimation accuracy through an innovative depth-first scanning mechanism. The proposed framework comprises a Depth Local Visual Mamba module employing depth-first scanning to extract rich structural features, and a cross-query layer, which reframes depth estimation as a soft classification problem to significantly enhance robustness and uncertainty handling in complex endoscopic environments. Experimental results on the SimCol Dataset and C3VD demonstrate that the proposed method achieves high depth estimation accuracy, with Abs Rel of 0.070 and 0.084, respectively. These results correspond to error reductions of 16.7% and 19.4% compared to existing methods, highlighting the efficacy of the proposed approach.