Ahmadreza Eslami

Mr. Ahmadreza Eslami

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
AEAhmadreza Eslami
Ahmadreza Eslami
Michael NegnevitskyMichael Negnevitsky
Michael Negnevitsky
EFEvan Franklin
Evan Franklin
SLSarah Lyden
Sarah Lyden

27 June 2022 in IEEE Access
Verified
Journal Article
Open access
AEAhmadreza Eslami
Ahmadreza Eslami
Michael NegnevitskyMichael Negnevitsky
Michael Negnevitsky
EFEvan Franklin
Evan Franklin
SLSarah Lyden
Sarah Lyden
In modern power systems, harmonics are amongst the significant issues attributed to renewable energy sources and nonlinear loads. Direct harmonic monitoring of the entire power system may be too costly or impractical, and measured data could be limited. In this paper, a new methodology is proposed to estimate harmonic current rms values of unmonitored harmonic sources, based on harmonic voltage rms magnitudes only, measured at a limited number of monitored buses. A new technique of output curve-normalization is employed in pre-processing. Subsequently, a method is proposed to refine the architecture of the Artificial Neural Networks’ (ANNs), after which ANN-based harmonic current estimators are developed for each harmonic order and each harmonic source. Furthermore, a novel Neural Oversampling Consensus Algorithm for Regression (NOCAR) is proposed to improve estimation accuracy. K-Nearest Neighbor (KNN) and ANN are combined in developing NOCAR. A comparison is made with state-of-the-art techniques by using synthetic data, which demonstrates both the proposed method’s robustness and its capability to perform when minimal information is available. The implementation for real data demonstrates the efficiency of the ANN-based harmonic current estimators with oversampling. The influence of the number of harmonic meters is investigated, revealing the ability of this data-driven technique to reduce the number of harmonic meters, and hence monitoring costs. Moreover, the correlation between different harmonic orders is studied, with results suggesting that, unlike the widely accepted notion, this correlation should not be ignored in harmonic analysis. This study highlights the advantages of integrating intelligent techniques into harmonic monitoring systems.

2 February 2019 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
AEAhmadreza Eslami
Ahmadreza Eslami
TGTeymoor Ghanbari
Teymoor Ghanbari
One of the recently arisen issues for transformerless grid‐connected photovoltaic (PV) systems is high‐frequency leakage current, which flows through the parasitic capacitance of PV system and the neutral grounding resistor (NGR) of the grid. This paper deals with a systemic analysis on the capacitance of large PV systems considering the interconnecting conductors. A new Y‐bus model is proposed to analyse the leakage current of PV strings/arrays of any size in high‐frequency domain. In the model, different capacitances of PV panels and the inductance and capacitance of interconnecting cables are considered. Subsequently, a two‐port circuit is derived by its admittance parameters, which is useful in leakage current studies. In the second step, a novel model for the common mode (CM) analysis of voltage‐source inverters is derived based on which, a new leakage current mitigation technique is proposed which provides capacitive CM paths for both the negative and positive legs of the inverter. The model is assessed using different simulations in various conditions. The results confirm the usefulness of the proposed model.

20 November 2017 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
AEAhmadreza Eslami
Ahmadreza Eslami
MGMohammad Esmail Hamedani Golshan
Mohammad Esmail Hamedani Golshan

7 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
AEAhmadreza Eslami
Ahmadreza Eslami
Michael NegnevitskyMichael Negnevitsky
Michael Negnevitsky
EFEvan Franklin
Evan Franklin
SLSarah Lyden
Sarah Lyden
Identification of harmonic sources contributing to harmonic distortion, and characterization of harmonic current injected by them, are crucial tasks in harmonic analysis of modern power systems. In this paper, these tasks are addressed based on the permissible current limits recommended by IEEE 519 Standard, with a determination of whether or not injected harmonics are within these limits. If limits are violated, the extent of the violations are characterized to provide information about harmonic current levels in the power system and facilitate remedial actions if necessary. A novel feature extraction method is proposed, whereby each set of harmonic measurements in a power system are transformed into a unique RGB image. Harmonic State Estimation (HSE) is discretized as a classification problem. Classifiers based on deep learning have been developed to subsequently locate and characterize harmonic sources. The approach has been demonstrated effectively both on the IEEE 14-bus system, and on a real transmission network where harmonics have been measured. A comparative study indicates that the proposed technique outperforms state-of-the-art techniques for HSE, including Bayesian Learning (BL), Singular Value Decomposition (SVD) and hybrid Genetic Algorithm Least Square (GALS) method in terms of accuracy and limited number of monitors.

19 December 2024 in IEEE Access
Verified
Journal Article
Open access
AEAhmadreza Eslami
Ahmadreza Eslami
Michael NegnevitskyMichael Negnevitsky
Michael Negnevitsky
EFEvan Franklin
Evan Franklin
SLSarah Lyden
Sarah Lyden
In modern power systems, the prevalence of harmonic distortion mandates robust monitoring. Harmonic monitoring faces formidable challenges due to significant uncertainties in measurements, network parameters, and the varying nature of harmonic sources alongside the limited deployment of harmonic meters and inaccessible nodes. A remedy involves the development of potentially uncertain voltage/current pseudo-meters. This paper proposes a novel probabilistic observability method used to estimate harmonic states within defined ranges with a confidence level. Subsequently, network buses are classified into three zones with regard to their harmonic state values being above, below, or uncertain relative to harmonic limits. Leveraging this approach, the number of actual harmonic meters, indicative of monitoring system cost, the bus misclassification index and the probability of misestimating harmonic states considering harmonic limits are minimized. The uncertainties in measurements, network parameters and varying outputs of harmonic sources are addressed. The developed monitoring system is capable of truly identifying buses with harmonic states violating or likely to violate harmonic limits (hot-spots). Demonstrations on IEEE 14-bus test system, IEEE 118-bus test system and the field measurements from the Tasmanian transmission network attest to the method’s efficacy, scalability and generalization capability, while considering high uncertainty in harmonic monitoring with fewer meters than the number of harmonic states. Comparative analysis with other HSE techniques and evaluation of the computational requirements of the proposed method demonstrate both its superiority and robustness. The proposed method provides a promising cost-effective approach for harmonic monitoring in modern power systems with high penetration of distributed harmonic sources.