Fokke van Meulen

Fokke van Meulen

Electrical Engineering, Eindhoven University of Technology, Eindhoven, Noord-Brabant, The Netherlands
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 November 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Fokke van MeulenFokke van Meulen
Fokke van Meulen
DWDirk Weenk
Dirk Weenk
EAEdwin H F Van Asseldonk
Edwin H F Van Asseldonk
HSH Martin Schepers
H Martin Schepers
PVPeter H Veltink
Peter H Veltink
JBJaap H Buurke
Jaap H Buurke
An important objective of rehabilitation care is to regain adequate balance function to safely ambulate in community. However, in rehabilitation practice, it remains unclear if a stroke survivor functionally recovers by restitution or by learning to compensate for the lack of restoration of body function. Aim of this study is to propose and evaluate methods for the objective evaluation of balance during functional walking in stroke survivors. Stroke survivors performed twice a Timed “Up & Go” (TUG) test. Ground reaction forces and position changes of both feet were measured using instrumented shoes and used to estimate the position of the center of mass (CoM). Balance control and efficiency metrics were defined to evaluate functional walking under variable conditions. Metrics were corrected based on the instantaneous velocity direction of CoM. Intra- and inter-participant variations for different phases of the TUG test were examined. Metrics were related to the Berg balance scale (BBS). Participants with higher BBS scores show a more efficient walking pattern. Their walking velocity and walking direction is less variable and they are more frequently unstable when walking in a straight line or when turning. Furthermore, the less affected participants are able to move their CoM more towards their affected side. We developed and demonstrated a method to assess walking balance of stroke survivors. System design and evaluation methods allow balance evaluation during functional walking in daily life. Some presented metrics show correlations with BBS scores. Clear inter- and intra-patient variations in metric values are present that cannot be explained by BBS scores, which supports the additional value of the presented system. Presented methods may be used for objective evaluation of restitution and compensation of walking balance and have a potential application in individual evidence-based therapy.

12 January 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
Fokke van MeulenFokke van Meulen
Fokke van Meulen
AGAngela Grassi
Angela Grassi
LHLeonie van Den Heuvel
Leonie van Den Heuvel
SOSebastiaan Overeem
Sebastiaan Overeem
MGMerel M van Gilst
Merel M van Gilst
PFPedro Fonseca
Pedro Fonseca
Polysomnography (PSG) remains the gold standard for sleep monitoring but is obtrusive in nature. Advances in camera sensor technology and data analysis techniques enable contactless monitoring of heart rate variability (HRV). In turn, this may allow remote assessment of sleep stages, as different HRV metrics indirectly reflect the expression of sleep stages. We evaluated a camera-based remote photoplethysmography (PPG) setup to perform automated classification of sleep stages in near darkness. Based on the contactless measurement of pulse rate variability, we use a previously developed HRV-based algorithm for 3 and 4-class sleep stage classification. Performance was evaluated on data of 46 healthy participants obtained from simultaneous overnight recording of PSG and camera-based remote PPG. To validate the results and for benchmarking purposes, the same algorithm was used to classify sleep stages based on the corresponding ECG data. Compared to manually scored PSG, the remote PPG-based algorithm achieved moderate agreement on both 3 class (Wake–N1/N2/N3–REM) and 4 class (Wake–N1/N2–N3–REM) classification, with average κ of 0.58 and 0.49 and accuracy of 81% and 68%, respectively. This is in range with other performance metrics reported on sensing technologies for wearable sleep staging, showing the potential of video-based non-contact sleep staging.

9 September 2020 in Journal of Medical Internet Research
Verified
Journal Article
Open access
RBRoel Boumans
Roel Boumans
Fokke van MeulenFokke van Meulen
Fokke van Meulen
WAWilliam van Aalst
William van Aalst
JAJoyce Albers
Joyce Albers
MJMarèse Janssen
Marèse Janssen
MRMarcel Olde Rikkert
Marcel Olde Rikkert
Background: Society is facing a global shortage of 17 million health care workers, along with increasing health care demands from a growing number of older adults. Social robots are being considered as solutions to part of this problem. Objective: Our objective is to evaluate the quality of care perceived by patients and caregivers for an integrated care pathway in an outpatient clinic using a social robot for patient-reported outcome measure (PROM) interviews versus the currently used professional interviews. Methods: A multicenter, two-parallel-group, nonblinded, randomized controlled trial was used to test for noninferiority of the quality of care delivered through robot-assisted care. The randomization was performed using a computer-generated table. The setting consisted of two outpatient clinics, and the study took place from July to December 2019. Of 419 patients who visited the participating outpatient clinics, 110 older patients met the criteria for recruitment. Inclusion criteria were the ability to speak and read Dutch and being assisted by a participating health care professional. Exclusion criteria were serious hearing or vision problems, serious cognitive problems, and paranoia or similar psychiatric problems. The intervention consisted of a social robot conducting a 36-item PROM. As the main outcome measure, the customized Consumer Quality Index (CQI) was used, as reported by patients and caregivers for the outpatient pathway of care. Results: In total, 75 intermediately frail older patients were included in the study, randomly assigned to the intervention and control groups, and processed: 36 female (48%) and 39 male (52%); mean age 77.4 years (SD 7.3), range 60-91 years. There was no significant difference in the total patient CQI scores between the patients included in the robot-assisted care pathway (mean 9.27, SD 0.65, n=37) and those in the control group (mean 9.00, SD 0.70, n=38): P=.08, 95% CI –0.04 to 0.58. There was no significant difference in the total CQI scores between caregivers in the intervention group (mean 9.21, SD 0.76, n=30) and those in the control group (mean 9.09, SD 0.60, n=35): P=.47, 95% CI –0.21 to 0.46. No harm or unintended effects occurred. Conclusions: Geriatric patients and their informal caregivers valued robot-assisted and nonrobot-assisted care pathways equally. Trial Registration: ClinicalTrials.gov NCT03857789; https://clinicaltrials.gov/ct2/show/NCT03857789

19 December 2024 in Sensors
Verified
Journal Article
Open access
PDF file
RARaquel Pires Alves
Raquel Pires Alves
Fokke van MeulenFokke van Meulen
Fokke van Meulen
SOSebastiaan Overeem
Sebastiaan Overeem
SZSveta Zinger
Sveta Zinger
SSSander Stuijk
Sander Stuijk
Continuous respiration monitoring is an important tool in assessing the patient’s health and diagnosing pulmonary, cardiovascular, and sleep-related breathing disorders. Various techniques and devices, both contact and contactless, can be used to monitor respiration. Each of these techniques can provide different types of information with varying accuracy. Thermal cameras have become a focal point in research due to their contactless nature, affordability, and the type of data they provide, i.e., information on respiration motion and respiration flow. Several studies have demonstrated the feasibility of this technology and developed robust algorithms to extract important information from thermal camera videos. This paper describes the current state-of-the-art in respiration monitoring using thermal cameras, dividing the system into acquiring data, defining and tracking the region of interest, and extracting the breathing signal and respiration rate. The approaches taken to address the various challenges, the limitations of these methods, and possible applications are discussed.

1 December 2023 in SLEEP
Verified
Journal Article
Closed access
PDF file
CWCaspar van der Woerd
Caspar van der Woerd
HGHans van Gorp
Hans van Gorp
SDSylvie Dujardin
Sylvie Dujardin
MSManuel Sastry
Manuel Sastry
HCHumberto Garcia Caballero
Humberto Garcia Caballero
PFPedro Fonseca
Pedro Fonseca
Study Objectives: Hypnograms contain a wealth of information and play an important role in sleep medicine. However, interpretation of the hypnogram is a difficult task and requires domain knowledge and “clinical intuition.” This study aimed to uncover which features of the hypnogram drive interpretation by physicians. In other words, make explicit which features physicians implicitly look for in hypnograms. Methods: Three sleep experts evaluated up to 612 hypnograms, indicating normal or abnormal sleep structure and suspicion of disorders. ElasticNet and convolutional neural network classification models were trained to predict the collected expert evaluations using hypnogram features and stages as input. The models were evaluated using several measures, including accuracy, Cohen’s kappa, Matthew’s correlation coefficient, and confusion matrices. Finally, model coefficients and visual analytics techniques were used to interpret the models to associate hypnogram features with expert evaluation. Results: Agreement between models and experts (Kappa between 0.47 and 0.52) is similar to agreement between experts (Kappa between 0.38 and 0.50). Sleep fragmentation, measured by transitions between sleep stages per hour, and sleep stage distribution were identified as important predictors for expert interpretation. Conclusions: By comparing hypnograms not solely on an epoch-by-epoch basis, but also on these more specific features that are relevant for the evaluation of experts, performance assessment of (automatic) sleep-staging and surrogate sleep trackers may be improved. In particular, sleep fragmentation is a feature that deserves more attention as it is often not included in the PSG report, and existing (wearable) sleep trackers have shown relatively poor performance in this aspect.

2 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
FSFons Schipper
Fons Schipper
AGAngela Grassi
Angela Grassi
MRMarco Ross
Marco Ross
ACAndreas Cerny
Andreas Cerny
PAPeter Anderer
Peter Anderer
PFPedro Fonseca
Pedro Fonseca
Overnight sleep staging is an important part of the diagnosis of various sleep disorders. Polysomnography is the gold standard for sleep staging, but less-obtrusive sensing modalities are of emerging interest. Here, we developed and validated an algorithm to perform “proxy” sleep staging using cardiac and respiratory signals derived from a chest-worn accelerometer. We collected data in two sleep centers, using a chest-worn accelerometer in combination with full PSG. A total of 323 participants were analyzed, aged 13–83 years, with BMI 18–47 kg/m2. We derived cardiac and respiratory features from the accelerometer and then applied a previously developed method for automatic cardio-respiratory sleep staging. We compared the estimated sleep stages against those derived from PSG and determined performance. Epoch-by-epoch agreement with four-class scoring (Wake, REM, N1+N2, N3) reached a Cohen’s kappa coefficient of agreement of 0.68 and an accuracy of 80.8%. For Wake vs. Sleep classification, an accuracy of 93.3% was obtained, with a sensitivity of 78.7% and a specificity of 96.6%. We showed that cardiorespiratory signals obtained from a chest-worn accelerometer can be used to estimate sleep stages among a population that is diverse in age, BMI, and prevalence of sleep disorders. This opens up the path towards various clinical applications in sleep medicine.