Merel M van Gilst

Dr. Merel M van Gilst

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Nature and Science of Sleep
Verified
Journal Article
Open access
PDF file
BWBernice M Wulterkens
Bernice M Wulterkens
PFPedro Fonseca
Pedro Fonseca
LHLieke Wa Hermans
Lieke Wa Hermans
MRMarco Ross
Marco Ross
ACAndreas Cerny
Andreas Cerny
SOSebastiaan Overeem
Sebastiaan Overeem
Purpose: There is great interest in unobtrusive long-term sleep measurements using wearable devices based on reflective photoplethysmography (PPG). Unfortunately, consumer devices are not validated in patient populations and therefore not suitable for clinical use. Several sleep staging algorithms have been developed and validated based on ECG-signals. However, translation from these techniques to data derived by wearable PPG is not trivial, and requires the differences between sensing modalities to be integrated in the algorithm, or having the model trained directly with data obtained with the target sensor. Either way, validation of PPG-based sleep staging algorithms requires a large dataset containing both gold standard measurements and PPG-sensor in the applicable clinical population. Here, we take these important steps towards unobtrusive, long-term sleep monitoring. Methods: We developed and trained an algorithm based on wrist-worn PPG and accelerometry. The method was validated against reference polysomnography in an independent clinical population comprising 244 adults and 48 children (age: 3 to 82 years) with a wide variety of sleep disorders. Results: The classifier achieved substantial agreement on four-class sleep staging with an average Cohen’s kappa of 0.62 and accuracy of 76.4%. For children/adolescents, it achieved even higher agreement with an average kappa of 0.66 and accuracy of 77.9%. Performance was significantly higher in non-REM parasomnias (kappa = 0.69, accuracy = 80.1%) and significantly lower in REM parasomnias (kappa = 0.55, accuracy = 72.3%). A weak correlation was found between age and kappa (ρ = − 0.30, p< 0.001) and age and accuracy (ρ = − 0.22, p< 0.001). Conclusion: This study shows the feasibility of automatic wearable sleep staging in patients with a broad variety of sleep disorders and a wide age range. Results demonstrate the potential for ambulatory long-term monitoring of clinical populations, which may improve diagnosis, estimation of severity and follow up in both sleep medicine and research.

25 November 2019 in BMJ Open
Verified
Journal Article
Open access
PDF file
MGMerel M van Gilst
Merel M van Gilst
Johannes Van DijkJohannes Van Dijk
Johannes Van Dijk
RKRoy Krijn
Roy Krijn
BHBertram Hoondert
Bertram Hoondert
PFPedro Fonseca
Pedro Fonseca
SOSebastiaan Overeem
Sebastiaan Overeem
Introduction Polysomnography (PSG) is the primary tool for sleep monitoring and the diagnosis of sleep disorders. Recent advances in signal analysis make it possible to reveal more information from this rich data source. Furthermore, many innovative sleep monitoring techniques are being developed that are less obtrusive, easier to use over long time periods and in the home situation. Here, we describe the methods of the Sleep and Obstructive Sleep Apnoea Monitoring with Non-Invasive Applications (SOMNIA) project, yielding a database combining clinical PSG with advanced unobtrusive sleep monitoring modalities in a large cohort of patients with various sleep disorders. The SOMNIA database will facilitate the validation and assessment of the diagnostic value of the new techniques, as well as the development of additional indices and biomarkers derived from new and/or traditional sleep monitoring methods. Methods and analysis We aim to include at least 2100 subjects (both adults and children) with a variety of sleep disorders who undergo a PSG as part of standard clinical care in a dedicated sleep centre. Full-video PSG will be performed according to the standards of the American Academy of Sleep Medicine. Each recording will be supplemented with one or more new monitoring systems, including wrist-worn photoplethysmography and actigraphy, pressure sensing mattresses, multimicrophone recording of respiratory sounds including snoring, suprasternal pressure monitoring and multielectrode electromyography of the diaphragm. Ethics and dissemination The study was reviewed by the medical ethical committee of the Maxima Medical Center (Eindhoven, the Netherlands, File no: N16.074). All subjects provide informed consent before participation. The SOMNIA database is built to facilitate future research in sleep medicine. Data from the completed SOMNIA database will be made available for collaboration with researchers outside the institute.

18 December 2020 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
Mark van GastelMark van Gastel
Mark van Gastel
SSSander Stuijk
Sander Stuijk
SOSebastiaan Overeem
Sebastiaan Overeem
Johannes Van DijkJohannes Van Dijk
Johannes Van Dijk
MGMerel M van Gilst
Merel M van Gilst
Gerard De HaanGerard De Haan
Gerard De Haan
Polysomnography (PSG) is the current gold standard for the diagnosis of sleep disorders. However, this multiparametric sleep monitoring tool also has some drawbacks, e.g. it limits the patient's mobility during the night and it requires the patient to come to a specialized sleep clinic or hospital to attach the sensors. Unobtrusive techniques for the detection of sleep disorders such as sleep apnea are therefore gaining increasing interest. Remote photoplethysmography using video is a technique which enables contactless detection of hemodynamic information. Promising results in near-infrared have been reported for the monitoring of sleep-relevant physiological parameters pulse rate, respiration and blood oxygen saturation. In this study we validate a contactless monitoring system on eight patients with a high likelihood of relevant obstructive sleep apnea, which are enrolled for a sleep study at a specialized sleep center. The dataset includes 46.5 hours of video recordings, full polysomnography and metadata. The camera can detect pulse and respiratory rate within 2 beats/breaths per minute accuracy 92% and 91% of the time, respectively. Estimated blood oxygen values are within 4 percentage-points of the finger-oximeter 89% of the time. These results demonstrate the potential of a camera as a convenient diagnostic tool for sleep apnea, and sleep disorders in general.

12 January 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
Fokke van MeulenFokke van Meulen
Fokke van Meulen
AGAngela Grassi
Angela Grassi
LHLeonie van Den Heuvel
Leonie van Den Heuvel
SOSebastiaan Overeem
Sebastiaan Overeem
MGMerel M van Gilst
Merel M van Gilst
PFPedro Fonseca
Pedro Fonseca
Polysomnography (PSG) remains the gold standard for sleep monitoring but is obtrusive in nature. Advances in camera sensor technology and data analysis techniques enable contactless monitoring of heart rate variability (HRV). In turn, this may allow remote assessment of sleep stages, as different HRV metrics indirectly reflect the expression of sleep stages. We evaluated a camera-based remote photoplethysmography (PPG) setup to perform automated classification of sleep stages in near darkness. Based on the contactless measurement of pulse rate variability, we use a previously developed HRV-based algorithm for 3 and 4-class sleep stage classification. Performance was evaluated on data of 46 healthy participants obtained from simultaneous overnight recording of PSG and camera-based remote PPG. To validate the results and for benchmarking purposes, the same algorithm was used to classify sleep stages based on the corresponding ECG data. Compared to manually scored PSG, the remote PPG-based algorithm achieved moderate agreement on both 3 class (Wake–N1/N2/N3–REM) and 4 class (Wake–N1/N2–N3–REM) classification, with average κ of 0.58 and 0.49 and accuracy of 81% and 68%, respectively. This is in range with other performance metrics reported on sensing technologies for wearable sleep staging, showing the potential of video-based non-contact sleep staging.

6 June 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PFPedro Fonseca
Pedro Fonseca
MRMarco Ross
Marco Ross
ACAndreas Cerny
Andreas Cerny
PAPeter Anderer
Peter Anderer
FMFokke van Meulen
Fokke van Meulen
SOSebastiaan Overeem
Sebastiaan Overeem
This study describes a computationally efficient algorithm for 4-class sleep staging based on cardiac activity and body movements. Using an accelerometer to calculate gross body movements and a reflective photoplethysmographic (PPG) sensor to determine interbeat intervals and a corresponding instantaneous heart rate signal, a neural network was trained to classify between wake, combined N1 and N2, N3 and REM sleep in epochs of 30 s. The classifier was validated on a hold-out set by comparing the output against manually scored sleep stages based on polysomnography (PSG). In addition, the execution time was compared with that of a previously developed heart rate variability (HRV) feature-based sleep staging algorithm. With a median epoch-per-epoch κ of 0.638 and accuracy of 77.8% the algorithm achieved an equivalent performance when compared to the previously developed HRV-based approach, but with a 50-times faster execution time. This shows how a neural network, without leveraging any a priori knowledge of the domain, can automatically “discover” a suitable mapping between cardiac activity and body movements, and sleep stages, even in patients with different sleep pathologies. In addition to the high performance, the reduced complexity of the algorithm makes practical implementation feasible, opening up new avenues in sleep diagnostics.

23 November 2018 in SLEEP
Verified
Journal Article
Open access
PDF file
LQLaury Quaedackers
Laury Quaedackers
MGMerel M van Gilst
Merel M van Gilst
PMPetra van Mierlo
Petra van Mierlo
GLGert Jan Lammers
Gert Jan Lammers
KDKarlien Dhondt
Karlien Dhondt
SOSebastiaan Overeem
Sebastiaan Overeem
To explore impairments in social functioning in pediatric narcolepsy patients compared to healthy children. Parents of 53 pediatric patients with narcolepsy type 1 and 64 matched healthy children completed the Social Responsiveness Scale (SRS) and the Child Behavior Checklist (CBCL 6–18). Patients scored significantly higher on the total score of the SRS (median 56, IQR 23.5) compared to controls (median 44.5, IQR 8.5, U = 797.0, p<0.001). Patients also scored higher on the sum of the CBCL 6–18 subscales indicative of social functioning (Withdrawn/Depressed, Social Problems and Thought Problems; median 183, IQR 30.5) compared to controls (median 155, IQR 13, U = 500.0, p<0.001). A total of 24 patients (45.3%) reported at least mild to moderate difficulties in social functioning compared to 7 controls (10.9%, χ2 =17.165, p <0.001). Eleven patients (20.8%) and only 1 control (1.6%) had T-scores above 75, which points to severely impaired social functioning (χ2= 11.602, p = 0.001). Within the patient group, girls reported mild to moderate difficulties in social functioning significantly more often compared to boys on the SRS (77.8% versus 28.6%, χ2= 17.560, p < 0.001). Impaired social functioning is common in children with narcolepsy type 1, especially in girls. Questionnaires such as the SRS and the CBCL 6–18 may help in early detection of social problems in pediatric narcolepsy. Recognition of these problems could be valuable in the management of young patients with narcolepsy.