Sameer Ahmad Hasan

Dr. Sameer Ahmad Hasan

Biomedical Engineering Department, School of Applied Medical Sciences, German Jordanian University, Amman, Al ‘Āşimah, Jordan
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 October 2023 in Materials
Verified
Journal Article
Open access
PDF file
WAWalid Al-Zyoud
Walid Al-Zyoud
DHDana Haddadin
Dana Haddadin
Sameer Ahmad HasanSameer Ahmad Hasan
Sameer Ahmad Hasan
HJHussamaldeen Jaradat
Hussamaldeen Jaradat
Olfa KanounOlfa Kanoun
Olfa Kanoun
This review article dives into the complex world of biocompatibility testing: chemical, mechanical, and biological characterization, including many elements of biocompatibility, such as definitions, descriptive examples, and the practical settings. The focus extends to evaluating standard documents obtained from reliable organizations; with a particular focus on open-source information, including FDA-USA, ISO 10933 series, and TÜV SÜD. We found a significant gap in this field: biomaterial scientists and those involved in the realm of medical device development in general, and implants in particular, lack access to a tool that reorganizes the process of selecting the appropriate biocompatibility test for the implant being examined. This work progressed through two key phases that aimed to provide a solution to this gap. A straightforward “yes or no” flowchart was initially developed to guide biocompatibility testing decisions based on the previously accumulated information. Subsequently, the Python code was employed, generating a framework through targeted questions. This work reshapes biocompatibility evaluation, bridging theory and practical implementation. An integrated approach via a flowchart and the Python code empowers stakeholders to navigate biocompatibility testing effortlessly. To conclude, researchers are now better equipped for a safer, more effective implant development, propelling the field towards improved patient care and innovative progress.

13 June 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RTRan Tao
Ran Tao
Sameer Ahmad HasanSameer Ahmad Hasan
Sameer Ahmad Hasan
HWH. Z. Wang
H. Z. Wang
JZJ. Zhou
J. Zhou
JLJingting Luo
Jingting Luo
RFRichard Fu
Richard Fu
A fundamental challenge for surface acoustic wave (SAW) temperature sensors is the detection of small temperature changes on non-planar, often curved, surfaces. In this work, we present a new design methodology for SAW devices based on flexible substrate and bimorph material/structures, which can maximize the temperature coefficient of frequency (TCF). We performed finite element analysis simulations and obtained theoretical TCF values for SAW sensors made of ZnO thin films (~5 μm thick) coated aluminum (Al) foil and Al plate substrates with thicknesses varied from 1 to 1600 μm. Based on the simulation results, SAW devices with selected Al foil or plate thicknesses were fabricated. The experimentally measured TCF values were in excellent agreements with the simulation results. A normalized wavelength parameter (e.g., the ratio between wavelength and sample thickness, λ/h) was applied to successfully describe changes in the TCF values, and the TCF readings of the ZnO/Al SAW devices showed dramatic increases when the normalized wavelength λ/h was larger than 1. Using this design approach, we obtained the highest reported TCF value of −760 ppm/K for a SAW device made of ZnO thin film coated on Al foils (50 μm thick), thereby enabling low cost temperature sensor applications to be realized on flexible substrates.

1 January 2019 in Surface and Coatings Technology
Verified
Journal Article
Open access
RTR. Tao
R. Tao
WWW.B. Wang
W.B. Wang
JLJ.T. Luo
J.T. Luo
Sameer Ahmad HasanSameer Ahmad Hasan
Sameer Ahmad Hasan
HTHamdi Torun
Hamdi Torun
RFRichard Fu
Richard Fu

11 October 2016 in IEEE Transactions on Electron Devices
Verified
Journal Article
Closed access
YLYong Liu
Yong Liu
JLJing Ting Luo
Jing Ting Luo
CZChao Zhao
Chao Zhao
JZJian Zhou
Jian Zhou
Sameer Ahmad HasanSameer Ahmad Hasan
Sameer Ahmad Hasan
RFRichard Fu
Richard Fu
This paper reports post-annealing of zinc oxide (ZnO) films on flexible foil substrates in order to improve the functional and acoustic wave sensing performance. ZnO films of 5 μm thick were deposited onto aluminum foils (50 μm thick) using magnetron sputtering and then annealed in air at different temperatures between 300 °C and 500 °C. Effects of postannealing on structural, optical, and device properties of the ZnO films and ZnO/Al foil acoustic wave devices were investigated. A temperature of 350 °C was identified as the optimized annealing temperature, which resulted in good light transmission, improved crystallinity, reduced film stress/defects, and increased amplitude of reflection signals of both Lamb and Rayleigh waves. The annealed ZnO/Al acoustic wave devices demonstrated a large temperature coefficient of frequency and a good linearity, revealing the potential for precise temperature sensing.

1 October 2017
Verified
Conference Paper
Closed access
Sameer Ahmad HasanSameer Ahmad Hasan
Sameer Ahmad Hasan
DGDesmond Gibson
Desmond Gibson
SSShigeng Song
Shigeng Song
Qiang WuQiang Wu
Qiang Wu
WNWai Pang Ng
Wai Pang Ng
RFRichard Fu
Richard Fu
ZnO thin film based flexible SAW devices were fabricated on commercial aluminum foils. The frequency responses were characterized and zero order Lamb wave modes were used to perform flexible temperature sensing. The devices exhibited a large value of temperature coefficient of frequency, good temperature sensitivity, and repeatability. They are promising to be used for flexible and wearable temperature sensing applications.

16 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
GSGhadeer Suaifan
Ghadeer Suaifan
MKMohammad Khanfar
Mohammad Khanfar
MSMayadah Shehadeh
Mayadah Shehadeh
AAAsmaa Alnajajrah
Asmaa Alnajajrah
RARaghad Abuhamdan
Raghad Abuhamdan
Sameer Ahmad HasanSameer Ahmad Hasan
Sameer Ahmad Hasan
An electroanalytical electrode for the detection of albendazole (ABZ) active ingredient in pharmaceutical dosage form and in contaminated animal-derived products was developed using a glassy carbon electrode modified with platinum-palladium nanoparticles. The electro-catalytic performance of the bimetallic-modified glassy carbon electrode was compared with its bare counterpart. Under optimized conditions, the modified electrode revealed two well-resolved anodic peak currents at 1.10 and 1.23 V using differential pulse voltammetry. Pure ABZ, as well as ABZ in spiked foods (milk and chicken), were detected with little interference from the food matrix. This electrode demonstrated high sensitivity and applicability, with a lower limit of detection of 0.08 µmol L−1 in aqueous solution and 10 µmol L−1 in the contaminated ground chicken and 100 µmol L−1 in the contaminated milk sample. The fabricated sensor is low in cost and appropriate for the estimation of albendazole in tablet dosage forms and biological samples, and so can act as a quality control tool in the pharmaceutical and food industry.