Wai Pang Ng

Dr. Wai Pang Ng

orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
RKRahul Kumar
Rahul Kumar
YLYuankui Leng
Yuankui Leng
Bin LiuBin Liu
Bin Liu
JZJun Zhou
Jun Zhou
LSLiyang Shao
Liyang Shao
Qiang WuQiang Wu
Qiang Wu

18 December 2015 in Applied Optics
Verified
Journal Article
Closed access
PDF file
ILIt Ee Lee
It Ee Lee
ZGZabih Ghassemlooy
Zabih Ghassemlooy
WNWai Pang Ng
Wai Pang Ng
MKMohammad-Ali Khalighi
Mohammad-Ali Khalighi
SLShien-Kuei Liaw
Shien-Kuei Liaw
Joint effects of aperture averaging and beam width on the performance of free-space optical communication links, under the impairments of atmospheric loss, turbulence, and pointing errors (PEs), are investigated from an information theory perspective. The propagation of a spatially partially coherent Gaussian-beam wave through a random turbulent medium is characterized, taking into account the diverging and focusing properties of the optical beam as well as the scintillation and beam wander effects. Results show that a noticeable improvement in the average channel capacity can be achieved with an enlarged receiver aperture in the moderate-to-strong turbulence regime, even without knowledge of the channel state information. In particular, it is observed that the optimum beam width can be reduced to improve the channel capacity, albeit the presence of scintillation and PEs, given that either one or both of these adverse effects are least dominant. We show that, under strong turbulence conditions, the beam width increases linearly with the Rytov variance for a relatively smaller PE loss but changes exponentially with steeper increments for higher PE losses. Our findings conclude that the optimal beam width is dependent on the combined effects of turbulence and PEs, and this parameter should be adjusted according to the varying atmospheric channel conditions. Therefore, we demonstrate that the maximum channel capacity is best achieved through the introduction of a larger receiver aperture and a beam-width optimization technique.

13 June 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RTRan Tao
Ran Tao
Sameer Ahmad HasanSameer Ahmad Hasan
Sameer Ahmad Hasan
HWH. Z. Wang
H. Z. Wang
JZJ. Zhou
J. Zhou
JLJingting Luo
Jingting Luo
RFRichard Fu
Richard Fu
A fundamental challenge for surface acoustic wave (SAW) temperature sensors is the detection of small temperature changes on non-planar, often curved, surfaces. In this work, we present a new design methodology for SAW devices based on flexible substrate and bimorph material/structures, which can maximize the temperature coefficient of frequency (TCF). We performed finite element analysis simulations and obtained theoretical TCF values for SAW sensors made of ZnO thin films (~5 μm thick) coated aluminum (Al) foil and Al plate substrates with thicknesses varied from 1 to 1600 μm. Based on the simulation results, SAW devices with selected Al foil or plate thicknesses were fabricated. The experimentally measured TCF values were in excellent agreements with the simulation results. A normalized wavelength parameter (e.g., the ratio between wavelength and sample thickness, λ/h) was applied to successfully describe changes in the TCF values, and the TCF readings of the ZnO/Al SAW devices showed dramatic increases when the normalized wavelength λ/h was larger than 1. Using this design approach, we obtained the highest reported TCF value of −760 ppm/K for a SAW device made of ZnO thin film coated on Al foils (50 μm thick), thereby enabling low cost temperature sensor applications to be realized on flexible substrates.

26 October 2017 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
Nageswara LalamNageswara Lalam
Nageswara Lalam
WNWai Pang Ng
Wai Pang Ng
XDXuewu Dai
Xuewu Dai
Qiang WuQiang Wu
Qiang Wu
RFRichard Fu
Richard Fu
In this paper, a wavelength diversity technique is employed in a Brillouin optical time domain reflectometry (BOTDR) using a Brillouin ring laser (BRL) as a local oscillator. In the wavelength diversity technique, multiple wavelengths are injected into the sensing fiber, while the peak power of each wavelength is set below the nonlinear threshold level. This technique significantly maximizes the overall launch pump power, without activating the non-negligible nonlinear effects, which overcomes the limitation of the conventional BOTDR system. The BRL, which is simple and cost-effective, that can be used to reduce the receiver bandwidth in the order of few MHz. In addition, a passive depolarizer is used to reduce the polarization noise. The proposed system is validated experimentally over a 50 km sensing fiber with a 5 m spatial resolution. The experimental results demonstrate a signal-to-noise ratio improvement of 5.1 dB, which corresponds to 180% improvement compared to a conventional BOTDR system.

2 February 2017 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
XLXixi Li
Xixi Li
DLDejun Liu
Dejun Liu
RKRahul Kumar
Rahul Kumar
WNWai Pang Ng
Wai Pang Ng
RFRichard Fu
Richard Fu
Qiang WuQiang Wu
Qiang Wu
A breathing sensor has been experimentally demonstrated based on a singlemode–multimode–singlemode (SMS) fiber structure which is attached to a thin plastic film in an oxygen mask. By detecting power variations due to the macro bending applied to the SMS section by each inhalation and exhalation process, the breath state can be monitored. The proposed sensor is capable of distinguishing different types of breathing conditions including regular and irregular breath state. The sensor can be used in a strong electric/magnetic field and radioactive testing systems such as magnetic resonance imaging (MRI) systems and computed tomography (CT) examinations where electrical sensors are restricted.

14 September 2022 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
Qian ZhangQian Zhang
Qian Zhang
YWYong Wang
Yong Wang
DLDongsheng Li
Dongsheng Li
Jin XieJin Xie
Jin Xie
RTRan Tao
Ran Tao
RFRichard Fu
Richard Fu
Flexible human–machine interfaces show broad prospects for next-generation flexible or wearable electronics compared with their currently available bulky and rigid counterparts. However, compared to their rigid counterparts, most reported flexible devices (e.g., flexible loudspeakers and microphones) show inferior performance, mainly due to the nature of their flexibility. Therefore, it is of great significance to improve their performance by developing and optimizing new materials, structures and design methodologies. In this paper, a flexible acoustic platform based on a zinc oxide (ZnO) thin film on an aluminum foil substrate is developed and optimized; this platform can be applied as a loudspeaker, a microphone, or an ambient sensor depending on the selection of its excitation frequencies. When used as a speaker, the proposed structure shows a high sound pressure level (SPL) of ~90 dB (with a standard deviation of ~3.6 dB), a low total harmonic distortion of ~1.41%, and a uniform directivity (with a standard deviation of ~4 dB). Its normalized SPL is higher than those of similar devices reported in the recent literature. When used as a microphone, the proposed device shows a precision of 98% for speech recognition, and the measured audio signals show a strong similarity to the original audio signals, demonstrating its equivalent performance compared to a rigid commercial microphone. As a flexible sensor, this device shows a high temperature coefficient of frequency of −289 ppm/K and good performance for respiratory monitoring.