Fetal Heart Rate (FHR), an important recording in Cardiotocography (CTG)-based fetal health status monitoring, is the only information that clinical obstetricians can directly obtain and use. A challenge, however, is that missing samples are very common in FHR due to various causes such as fetal movements and sensor malfunctions. The aim is the development of an inpainting tool which is suitable for different missing lengths $q$ and various total missing percentages $Q$ , as well as for use in online mode. This study focused on two major impediments to existing inpainting methods: the longer the missing length, the more difficult it is to recover with mathematical methods; the reliance on tens of thousands of training samples, and the computational burden caused by full batch-based dictionary learning algorithms. We present a regularized minimization approach to signal recovery, which combines a ${{\rm{L}}_{{0}{\rm{.6}}}}{\rm{ - norm}}$ minimized sparse dictionary learning algorithm (MSDL) and a model optimization strategy for using a mini-batch version for signal recovery. Using 100 FHR recordings with 2 protocols designed to simulate missing clinical data scenarios, the combined method performed favorably in terms of 5 data analysis metrics and 3 clinical indicators. Comparing 4 inpainting methods, we were able to prove the superiority of the proposed algorithm for both large $q$ and large $Q$ . The experimental results showed the lowest values (2.64 (MAE), 4.68 (RMSE)) when ${\rm{Q}} = {\rm{5\% }}$ with short interval lengths. The developed architecture provides a reference value for the practical application of recovering missing samples online.
2 September 2021 in Frontiers of Information Technology & Electronic Engineering
Physiological signal based biometric analysis has recently attracted attention as a means of meeting increasing privacy and security requirements. The real
Fetal distress is the main cause of frequent adverse events such as asphyxia and disability. It is particularly important to monitor the fetal intrauterine state in late pregnancy so as to detect fetal abnormalities in time. Cardiotocography (CTG) is an important tool for fetal health assessment in clinical practice. But the accuracy and consistency of CTG are generally not ideal as the correct interpretation is affected by the doctor's clinical experience and ability. Therefore, this paper proposed an intelligent assistant diagnosis algorithm based on fetal heart rate (FHR) signals, which integrated by the input layer construction based on MelFrequency Cepstral Coefficients (MFCCs) and the deep neural network model based on bidirectional long short-term memory (BLSTM). Through 200 sets of intrapartum data from a public database, the results show that the proposed algorithm achieves a high accuracy of 96.25%, which can achieve a pretty well assessment of the fetal state and assist clinicians to make an auxiliary diagnosis of the fetal health.
10 July 2024 in IEEE Transactions on Consumer Electronics
Fetal Heart Rate (FHR) signal is widely used in doppler fetal heart monitors. However, incomplete FHR signals reduce the effectiveness of fetal heart rate monitoring. Filling missing data is a key technique to improve FHR quality, but existing filling algorithms lack consideration the correlation of FHR signals. Therefore, we focus on two correlations related to FHR, and propose a filling algorithm called Diffusion model for Missing Data Imputation in FHR (DMDI-FHR). Firstly, we construct the Dual-dimensional Sample Construction (DDSC) method that finds two FHR signals with maximizing the difference to form correlations between them. Secondly, the Multi-period Decomposition (MPD) method is introduced to obtain the internal correlation of FHR signal. Finally, DMDI-FHR algorithm controls the filling process based on the diffusion model. Experimental results demonstrate the performance of DMDI-FHR algorithm, which provides an effective way to improve the quality of FHR signal.