Jose Luis Calvo-Rolle

Prof. Dr. Jose Luis Calvo-Rolle

University of A Coruña
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2023 in Expert Systems
Verified
Journal Article
Open access
ÁGÁlvaro Michelena Grandío
Álvaro Michelena Grandío
JAJose Aveleira-Mata
Jose Aveleira-Mata
Esteban JoveEsteban Jove
Esteban Jove
MBMartin Bayon
Martin Bayon
Paulo NovaisPaulo Novais
Paulo Novais
HAHector Alaiz-Moreton
Hector Alaiz-Moreton
One of the most common attacks is man‐in‐the‐middle (MitM) which, due to its complex behaviour, is difficult to detect by traditional cyber‐attack detection systems. MitM attacks on internet of things systems take advantage of special features of the protocols and cause system disruptions, making them invisible to legitimate elements. In this work, an intrusion detection system (IDS), where intelligent models can be deployed, is the approach to detect this type of attack considering network alterations. Therefore, this paper presents a novel method to develop the intelligent model used by the IDS, being this method based on a hybrid process. The first stage of the process implements a feature extraction method, while the second one applies different supervised classification techniques, both over a message queuing telemetry transport (MQTT) dataset compiled by authors in previous works. The contribution shows excellent performance for any compared classification methods. Likewise, the best results are obtained using the method with the highest computational cost. Thanks to this, a functional IDS will be able to prevent MQTT attacks.

29 October 2014 in Sensors
Verified
Journal Article
Open access
PDF file
CTConcepción Crespo Turrado
Concepción Crespo Turrado
CMCarmen Meizoso-López
Carmen Meizoso-López
Fernando Sanchez LasherasFernando Sanchez Lasheras
Fernando Sanchez Lasheras
BGBenigno Antonio Rodríguez Gómez
Benigno Antonio Rodríguez Gómez
Jose Luis Calvo-RolleJose Luis Calvo-Rolle
Jose Luis Calvo-Rolle
FJFrancisco Javier De Cos Juez
Francisco Javier De Cos Juez
Global solar broadband irradiance on a planar surface is measured at weather stations by pyranometers. In the case of the present research, solar radiation values from nine meteorological stations of the MeteoGalicia real-time observational network, captured and stored every ten minutes, are considered. In this kind of record, the lack of data and/or the presence of wrong values adversely affects any time series study. Consequently, when this occurs, a data imputation process must be performed in order to replace missing data with estimated values. This paper aims to evaluate the multivariate imputation of ten-minute scale data by means of the chained equations method (MICE). This method allows the network itself to impute the missing or wrong data of a solar radiation sensor, by using either all or just a group of the measurements of the remaining sensors. Very good results have been obtained with the MICE method in comparison with other methods employed in this field such as Inverse Distance Weighting (IDW) and Multiple Linear Regression (MLR). The average RMSE value of the predictions for the MICE algorithm was 13.37% while that for the MLR it was 28.19%, and 31.68% for the IDW.

31 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Jose Luis Calvo-RolleJose Luis Calvo-Rolle
Jose Luis Calvo-Rolle
JGJOSE-FRANCISCO GOMEZ-GONZALEZ
JOSE-FRANCISCO GOMEZ-GONZALEZ
Jose Luis Calvo-RolleJose Luis Calvo-Rolle
Jose Luis Calvo-Rolle
Esteban JoveEsteban Jove
Esteban Jove
HQHector Quintian
Hector Quintian
Juan Albino Mendez PerezJuan Albino Mendez Perez
Juan Albino Mendez Perez
The hotel industry is an important energy consumer that needs efficient energy management methods to guarantee its performance and sustainability. The new role of hotels as prosumers increases the difficulty in the design of these methods. Also, the scenery is more complex as renewable energy systems are present in the hotel energy mix. The performance of energy management systems greatly depends on the use of reliable predictions for energy load. This paper presents a new methodology to predict energy load in a hotel based on intelligent techniques. The model proposed is based on a hybrid intelligent topology implemented with a combination of clustering techniques and intelligent regression methods (Artificial Neural Network and Support Vector Regression). The model includes its own energy demand information, occupancy rate, and temperature as inputs. The validation was done using real hotel data and compared with time-series models. Forecasts obtained were satisfactory, showing a promising potential for its use in energy management systems in hotel resorts.


1 January 2014 in Informatica
Verified
Journal Article
Closed access
HQHector Quintian
Hector Quintian
Jose Luis Calvo-RolleJose Luis Calvo-Rolle
Jose Luis Calvo-Rolle
ECEmilio Corchado
Emilio Corchado

1 October 2013 in Expert Systems with Applications
Verified
Journal Article
Open access
Jose Luis Calvo-RolleJose Luis Calvo-Rolle
Jose Luis Calvo-Rolle
HQHector Quintian
Hector Quintian
CMCarmen Meizoso-López
Carmen Meizoso-López