In an increasingly interconnected world, where electronic devices permeate every aspect of our lives, wearable systems aimed at monitoring physiological signals are rapidly taking over the sport and fitness domain, as well as biomedical fields such as rehabilitation and prosthetics. With the intent of providing a novel approach to the field, in this paper we discuss the development of a wearable system for the acquisition of EEG signals based on a portable, low-power custom PCB specifically designed to be used in combination with non-conventional ultra-conformable and imperceptible Parylene-C tattoo electrodes. The proposed system has been tested in a standard rest-state experiment, and its performance in terms of discrimination of two different states has been compared to that of a commercial wearable device for EEG signal acquisition (i.e., the Muse headset), showing comparable results. This first preliminary validation demonstrates the possibility of conveniently employing ultra-conformable tattoo-electrodes integrated portable systems for the unobtrusive acquisition of brain activity.
Transcutaneous Electrical Nerve Stimulation (TENS) is a promising technique for eliciting referred tactile sensations in patients with limb amputation. Although several studies show the validity of this technique, its application in daily life and away from laboratories is limited by the need for more portable instrumentation that guarantees the necessary voltage and current requirements for proper sensory stimulation. This study proposes a low-cost, wearable high-voltage compliant current stimulator with four independent channels based on Components-Off-The-Shelf (COTS). This microcontroller-based system implements a voltage-current converter controllable through a digital-to-analog converter that delivers up to 25 mA to load up to 3.6 kΩ. The high-voltage compliance enables the system to adapt to variations in electrode-skin impedance, allowing it to stimulate loads over 10 kΩ with currents of 5 mA. The system was realized on a four-layer PCB (115.9 mm × 61 mm, 52 g). The functionality of the device was tested on resistive loads and on an equivalent skin-like RC circuit. Moreover, the possibility of implementing an amplitude modulation was demonstrated.
Skeletal muscle tissue represents an attractive powering component for biohybrid robots, as traditional actuators used in the soft robotic context often rely on complex mechanisms and lack scalability at small dimensions. This article proposes a monolithic biohybrid flexure mechanism actuated by a bioengineered skeletal muscle tissue. The design leverages the contractile properties of a bioengineered skeletal muscle to produce a bending motion in a monolithic, tubular mechanism made of a soft and biocompatible silicone blend. This structure integrates two cylindrical pillars that facilitate force transmission from the bioengineered muscle tissue. Performance assessments reveal excellent contractile and stable behavior upon electrical stimulation, compared to current biohybrid actuation systems, with enhanced performance as the mechanism's internal and external diameters decrease. Finite‐element simulations further reveal distinct force–displacement responses in mechanisms with different flexural rigidity. This innovative, scalable, and easy‐to‐fabricate design represents a significant step forward in the development of novel biohybrid machines.
This study presents a comprehensive evaluation and an equivalent circuit modeling of the skin–electrode impedance characteristics of three types of ultra-thin tattoo electrodes, all based on Parylene C nanofilms but with different active materials: Gold, Silver, and PEDOT:PSS. Their performance was compared to standard disposable Ag/AgCl electrodes. Impedance measurements were carried out on six human subjects under controlled conditions, assessing the frequency response in the range of 20 Hz to 1 kHz. For each subject, the impedance was recorded six times over one hour to investigate the stability and the temporal performance. The collected data were subsequently analyzed to model the electrical properties and interface behavior of each electrode type. The findings demonstrate that the tattoo electrodes offer impedance levels comparable to those of Ag/AgCl electrodes (in the order of tens of kΩ at 20 Hz), while providing additional benefits such as enhanced conformability, improved skin adhesion, and reduced skin irritation during use. Furthermore, the modeling of the skin–electrode interface through a more detailed equivalent circuit than the single time constant model enables a more detailed interface analysis and description, with fitting algorithm R2 scores of about 0.999 and 0.979 for the impedance magnitude and impedance phase, respectively. The proposed equivalent circuit offers valuable insights for optimizing electrode design, supporting the potential of Parylene C-based tattoo electrodes as promising alternatives for next-generation wearable bioelectronic applications.
The restoration of sensory feedback is one of the current challenges in the field of prosthetics. This work, following the analysis of the various types of sensory feedback, aims to present a prototype device that could be used both for implantable applications to perform PNS and for wearable applications, performing TENS, to restore sensory feedback. The two systems are composed of three electronic boards that are presented in detail, as well as the bench tests carried out. To the authors’ best knowledge, this work presents the first device that can be used in a dual scenario for restoring sensory feedback. Both the implantable and wearable versions respected the expected values regarding the stimulation parameters. In its implantable version, the proposed system allows simultaneous and independent stimulation of 30 channels. Furthermore, the capacity of the wearable version to elicit somatic sensations was evaluated on healthy participants demonstrating performance comparable with commercial solutions.
Soft and flexible robotics is an emerging field that attracts a huge interest due to its ability to produce bioinspired devices that are easily adaptable to the environment. Biohybrid Machines (BHM) represent a category of soft robots that integrate biological tissues, such as engineered muscle tissues, as actuating systems. Although these devices present several advantages in some applications, their proper actuation still represents a challenge for researchers. This paper focuses on the development of a portable and programmable electrical stimulator designed to control muscle fiber-based biohybrid actuators. The stimulator, made using off-the-shelf components, was designed as a stacking of three independent printed circuit boards (PCBs), connected vertically in order to result in a final device with compact dimensions of 59 mm \(\times\) 28 mm \(\times\) 25 mm. The stimulation circuit is capable of delivering currents up to 18 mA with a voltage compliance of ± 90 V, and a power consumption of approximately 1.3 W. The device’s ability to induce twitch and tetanic contractions in a biohybrid actuator is demonstrated in different stimulation conditions. A practical application was also explored through a test case involving a flexible catheter prototype controlled by a biohybrid actuator, demonstrating its potential utility in a BHMs.