Alessia Scarpelli

Ms. Alessia Scarpelli

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2020 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
ASAlessia Scarpelli
Alessia Scarpelli
ADAndrea Demofonti
Andrea Demofonti
FTFrancesca Terracina
Francesca Terracina
ACAnna Lisa Ciancio
Anna Lisa Ciancio
LZLoredana Zollo
Loredana Zollo
The restoration of sensory feedback in amputees plays a fundamental role in the prosthesis control and in the communication on the afferent channel between hand and brain. The literature shows that transcutaneous electrical nerve stimulation (TENS) can be a promising non-invasive technique to elicit sensory feedback in amputees, especially in the lower limb through the phenomenon of apparent moving sensation (AMS). It consists of delivering a sensation that moves along a specific part of the body. This study proposes to use TENS to elicit tactile sensations and adopt AMS to reproduce moving sensations on the hand, such as those related to an object moving in the hand or slipping upward or downward. To this purpose, the developed experimental protocol consists of two phases: (i) the mapping of the evoked sensations and (ii) the generation of the AMS. In the latter phase, the pulse amplitude variation (PAV), the pulse width variation (PWV), and the interstimulus delay modulation (ISDM) methods were compared. For the comparative analysis, the Wilcoxon–Mann–Whitney test with Bonferroni correction (P < 0.016) was carried out on the success rate and on the ranking of methods expressed by the subjects. Results from the mapping protocol show that the delivered sensations were mostly described by the subjects as almost natural and superficial tingling. Results from the AMS protocol show that, for each movement direction, the success rate of ISDM method is higher than that of PWV and PAV and significantly higher than that of PAV for the ulnar-median direction. It recreates an AMS in the hand that effectively allows discriminating the type of sensation and distinguishing the movement direction. Moreover, ISDM was ranked by the subjects as the favorite method for recreating a well-defined and comfortable moving sensation only in the median-ulnar direction. For the ranking results, there was not a statistically significant difference among the methods. The experiments confirmed the good potential of recreating an AMS in the hand through TENS. This encourages to push forward this study on amputees and integrate it in the closed-loop control of a prosthetic system, in order to enable full control of grasp stability and prevent the objects from slippage.

14 August 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
ASAlessia Scarpelli
Alessia Scarpelli
ADAndrea Demofonti
Andrea Demofonti
Francesca CordellaFrancesca Cordella
Francesca Cordella
UCU. Coffa
U. Coffa
FMFederico Mereu
Federico Mereu
LZLoredana Zollo
Loredana Zollo
Upper limb amputation severely affects the quality of life of individuals. Therefore, developing closed-loop upper-limb prostheses would enhance the sensory-motor capabilities of the prosthetic user. Considering design priorities based on user needs, the restoration of sensory feedback is one of the most desired features. This study focuses on employing Transcutaneous Electrical Nerve Stimulation (TENS) as a non-invasive somatotopic stimulation technique for restoring somatic sensations in upper-limb amputees. The aim of this study is to propose two encoding strategies to elicit force and slippage sensations in transradial amputees. The former aims at restoring three different levels of force through a Linear Pulse Amplitude Modulation (LPAM); the latter is devoted to elicit slippage sensations through Apparent Moving Sensation (AMS) by means of three different algorithms, i.e. the Pulse Amplitude Variation (PAV), the Pulse Width Variation (PWV) and Inter-Stimulus Delay Modulation (ISDM). Amputees had to characterize perceived sensations and to perform force and slippage recognition tasks. Results demonstrates that amputees were able to correctly identify low, medium and high levels of force, with an accuracy above the 80% and similarly, to also discriminate the slippage moving direction with a high accuracy above 90%, also highlighting that ISDM would be the most suitable method, among the three AMS strategies to deliver slippage sensations. It was demonstrated for the first time that the developed encoding strategies are effective methods to somatotopically reintroduce in the amputees, by means of TENS, force and slippage sensations.

30 March 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
FMFederico Mereu
Federico Mereu
Francesca CordellaFrancesca Cordella
Francesca Cordella
RPRoberto Paolini
Roberto Paolini
ASAlessia Scarpelli
Alessia Scarpelli
ADAndrea Demofonti
Andrea Demofonti
EGEmanuele Gruppioni
Emanuele Gruppioni
The restoration of sensory feedback is one of the current challenges in the field of prosthetics. This work, following the analysis of the various types of sensory feedback, aims to present a prototype device that could be used both for implantable applications to perform PNS and for wearable applications, performing TENS, to restore sensory feedback. The two systems are composed of three electronic boards that are presented in detail, as well as the bench tests carried out. To the authors’ best knowledge, this work presents the first device that can be used in a dual scenario for restoring sensory feedback. Both the implantable and wearable versions respected the expected values regarding the stimulation parameters. In its implantable version, the proposed system allows simultaneous and independent stimulation of 30 channels. Furthermore, the capacity of the wearable version to elicit somatic sensations was evaluated on healthy participants demonstrating performance comparable with commercial solutions.

9 September 2025 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
RPRoberto Paolini
Roberto Paolini
Riccardo ColluRiccardo Collu
Riccardo Collu
LTLaura Tullio
Laura Tullio
ADAndrea Demofonti
Andrea Demofonti
ASAlessia Scarpelli
Alessia Scarpelli
LZLoredana Zollo
Loredana Zollo
Neuroprostheses capable of providing Somatotopic Sensory Feedback (SSF) enables the restoration of tactile sensations in amputees, thereby enhancing prosthesis embodiment, object manipulation, balance and walking stability. Transcutaneous Electrical Nerve Stimulation (TENS) represents a primary non-invasive technique for eliciting somatotopic sensations. Devices commonly used to evaluate the effectiveness of TENS stimulation are often bulky and main powered. However, current portable TENS devices frequently fall short of key functional requirements, particularly in terms of stimulation parameter ranges that are insufficient to reliably evoke somatotopic sensations in either upper and lower limb applications. Moreover, they typically do not support real-time independent channels programming and wireless communication. This work introduces a compact, wearable stimulator, including its external casing, with a total weight of 64 g and dimensions of 70 ${\boldsymbol{\times}}$ 40 ${\boldsymbol{\times}}$ 35 mm, designed to deliver SSF in both upper and lower limb applications. The device was validated through bench testing and human trials involving 20 healthy participants, by comparing the intensity, qualitative characteristics, and referred area of the elicited sensations with those produced by a benchmark. The stimulator reliably delivered the required parameters on a skin-like capacitive-resistive load and elicited somatotopic sensations consistent with the benchmark device and prior somatotopic feedback studies. The proposed stimulator provides non-invasive somatotopic sensory feedback for both upper and lower limbs. Its portability and modular design address key limitations of current commercial and research-grade TENS systems, enabling future studies on the functional benefits of sensory feedback in prosthetic control.

4 July 2025 in Journal of Neural Engineering
Verified
Journal Article
Open access
ASAlessia Scarpelli
Alessia Scarpelli
Francesca CordellaFrancesca Cordella
Francesca Cordella
LZLoredana Zollo
Loredana Zollo
Objective. Sensory feedback restoration represents a fundamental need for upper limb prosthesis users because it permits to feel somatic sensations during interactions with the environment. Considering the artificial sensory transduction, neuroprotheses should take advantage of effective encoding algorithms, which have the essential role, in the sensory feedback process, of coding the intended perception to the individual with the amputation. This paper presents a literature systematic review of the encoding algorithms employed for somatotopically restoring somatic sensations in upper limb of individuals with the intact arm or with an amputation. Approach. The methodologies adopted for the development of the encoding algorithms were deeply analyzed to describe what is the current state of the art on this topic. Encoding algorithms validated in literature on upper limb were grouped into three main categories (Function-based, Bio-inspired and Hybrid) and then compared and described. Main results. Function-based Algorithms provide the user with high sensitivity, whereas if the verisimilitude to natural sensation and complexity are the most desirable features for sensory feedback, a Bio-inspired strategy would be the most suitable to implement. However, Hybrid solutions both evoked realistic sensations and enhanced discrimination capabilities. Significance. The conducted analysis represents a guide for understanding which type of encoding to choose, making a compromise between the characteristics of the elicited sensations and the achieved performance. This critical analysis will give the reader important information for understanding the potentiality of the encoding strategies to elicit different sensations for a specific application and for developing novel sensory restoration approaches.

1 December 2022 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
ASAlessia Scarpelli
Alessia Scarpelli
MSMattia Stefano
Mattia Stefano
FCFrancesca Cordella
Francesca Cordella
LZLoredana Zollo
Loredana Zollo
The lack of sensory feedback represents one of the main drawbacks of commercial upper limb prosthesis. Transcranial Focused Ultrasound Stimulation (tFUS) seems to be a valid non-invasive technique for restoring sensory feedback allowing to deliver acoustic energy to cortical sensory areas with high spatial resolution and depth penetration. This paper aims at studying in simulation the use of tFUS on cortical sensory areas to evaluate its effects in terms of latency ad firing rate of the cells response, for understanding if these parameters influence the safety and the efficacy of the stimulation. In this paper, in order to study the propagation of the ultrasound wave from the transducer to the cortical cells, a multiscale approach was implemented by building a macroscopic model, which estimates the pressure profile in a simplified 2D human head geometry, and coupling it with the SONIC microscale model, that describes the electrical behaviour of a cortical neuron. The influence of the stimulation parameters and of the skull thickness on the latency and the firing rate are evaluated and the obtained behaviour is linked to the sensory response obtained on human subjects. Results have shown that slight changes in the transducer position should not affect the efficacy of the stimulation; however, high skull thickness leads to lower cells activation. These results will be useful for evaluating safety and effectiveness of tFUS for sensory feedback in closed-loop prosthetic systems.