Noor Alia Md Zain

Mrs. Noor Alia Md Zain


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
NZNoor Alia Md Zain
Noor Alia Md Zain
RDR Daud
R Daud
NKN S Kamarrudin
N S Kamarrudin
KAK R Ahmad
K R Ahmad
NAN H A Aziz
N H A Aziz
For centuries, the finite element (FE) method has been extensively used to predict the fracture performance and various method has been implemented to yield accurate results especially in healthcare industries. Bone fracture has been a critical problem since it interrupts the strength and structure of human bone. Thus, this problem will lead to bone malfunction and cause excess bleeding of surround tissues. Human bone consists of cortical and trabecular bone which serve a different amount of load sustainability before the fracture occurred. One of the most vital problems arise is the inaccuracy of the stress intensity factor related to the bone fracture. Recent studies have proven that with the implementation of appropriate meshing element produce higher accuracy results especially with the implementation of mesh refinement in the finite element model. The singularity elements suggested by Barsoum (1976) has proven that the quarter-point triangular elements give highly accurate results. Several methods for stress intensity factor calculation has been implemented by various past researchers. Among all the methods used, J-integral has proven to be the most accurate method compared to the others. The first section in your paper.

1 January 2016 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
NZNoor Alia Md Zain
Noor Alia Md Zain
RDRuslizam Daud
Ruslizam Daud
The analysis of amplified stress interaction in cortical bone is relatively new since most previous research have neglected the error parameter of fracture without realizing the accuracy of prediction has been violated, numerically. Indeed, the related analytical and empirical formulation for stress interaction analysis for example Kachanov theory is relatively accurate for very specific case. Thus, an approach that would produce less error for better prediction is paramount. The crack interaction parameter using the stress singularity element is one of alternative approach. This simulation is based on the changes of stress amplification in different crack intervals. Stress amplification in a solid, with the existence of crack is the amount of load that exhibits onto the solid perpendicularly. This research aims is to simulate stress amplification induced by crack interaction in cortical bone. Hence, the average error of the numerical method has been discussed and validated.

20 June 2025 in Jurnal Mekanikal
Verified
Journal Article
Open access
PDF file
NZNoor Alia Md Zain
Noor Alia Md Zain
RDRuslizam Daud
Ruslizam Daud
MAMuhamad Safwan Muhamad Azmi
Muhamad Safwan Muhamad Azmi
NNNoor Fazliah Mohd Noor
Noor Fazliah Mohd Noor
This paper aims to examine the response of double edge cracks in alveolar bone under Mode II loading with emphasis on differences in crack behaviour between homogeneous (cancellous) and heterogeneous (cortical-cancellous) bone types. Implant placement exerts load on the alveolar bone and consequently causes microcracks that would influence the stability of the implant and the bone. Such fractures and their relation to the composition of the human bones must be better understood to enhance the design of the implant. Crack behaviour was studied using a 2D continuum mechanics model of the dimension 1mm x 1mm. The crack length-to-width ratio of the upper crack varied in the range of 0.125 mm to 0.5 mm, and the lower crack was held constant at 0.125 mm. The goal of the study is to investigate Mode II loading of cancellous and cortical-cancellous bone materials where stress intensity factors (SIF) and normalized SIF values are a particular focus. In the homogeneous cancellous bone model, stress shielding occurred and normalized SIF values from 0.176 to 0.717 were consistently demonstrated. While the heterogeneous model initially showed similar shielding behavior (SIF ranging from 0.039 to 0.053), a transition was observed from shielding to stress amplification to SIF increasing from 0.053 to 1.205, with a unification point at a/W ≈ 0.3119. We observe that the cortical layer initially disperses the applied shear stress; however, as the crack length increases beyond a critical threshold, stress amplification occurs. Thus, the relevance of bone heterogeneity to the crack behavior is emphasized and the need to account for material composition in the implant design and placement for improving implant mechanical stability and durability is confirmed.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
IBIZZAWATI BASIROM
IZZAWATI BASIROM
RDRUSLIZAM DAUD
RUSLIZAM DAUD
MAM. Afendi
M. Afendi
MMM.S. Abdul Majid
M.S. Abdul Majid
NZNoor Alia Md Zain
Noor Alia Md Zain
Finite element models have been widely used to quantify the stress analysis and to predict the bone fractures of the human body. The present study highlights on the stress analysis of the homogeneous structure of human femur bone during standing up condition. The main objective of this study is to evaluate and understand the biomechanics for human femur bone and to prepare orthotropic homogeneous material models used for FE analysis of the global proximal femur. Thus, it is necessary to investigate critical stress on the human femur bone for future study on implantation of internal fixator and external fixator. The implication possibility to create a valid FE model by simply comparing the FE results with the actual biomechanics structures. Thus, a convergence test was performed by FE model of the femur and the stress analysis based on the actual biomechanics of the human femur bone. An increment of critical stress shows in the femur shaft as the increasing of load on the femoral head and decreasing the pulling force at greater trochanter.

2 September 2026
Verified
Book Chapter
Closed access
PDF file
IZIwana Zainuldin
Iwana Zainuldin
NZNoor Alia Md Zain
Noor Alia Md Zain
RDRuslizam Daud
Ruslizam Daud
NKNorzarul Asri Kamis
Norzarul Asri Kamis
NGNurul Fadzlin Ghazali
Nurul Fadzlin Ghazali