This study aims to summarize the current state of scientific knowledge on factors that contribute to heat generation during the bone drilling process and how these aspects can be better understood and avoided in the future through new research methodologies. Frictional pressures, mechanical trauma, and surgical methods can cause thermal damage and significant micro-fracturing, which can impede bone recovery. According to current trends in the technical growth of the dental and orthopedic industries’ 4.0 revaluation, enhancing drill bit design is one of the most feasible and cost-effective alternatives. In recent years, research on drilling bones has become important to reduce bone tissue damage, such as osteonecrosis (ON), and other problems that can happen during surgery. Reviewing the influence of feed rate, drill design, drill fatigue, drill speed, and force applied during osteotomies, all of which contribute to heat generation, was a major focus of this article. This comprehensive review can aid medical surgeons and drill bit makers in comprehending the recent improvements through optimization strategies for reducing or limiting thermal damage in bone drilling procedures used in the dental and orthopedic industries.
An understanding of the biomechanical characteristics and configuration of flexible and locked plating in order to provide balance stability and flexibility of implant fixation will help to construct and promote fast bone healing. The relationship between applied loading and implantation configuration for best bone healing is still under debate. This study aims to investigate the relationship between implant strength, working length, and interfragmentary strain (εIFM) on implant stability for femoral midshaft transverse fractures. The transverse fracture was fixed with a fragment locking compression plate (LCP) system. Finite element analysis was performed and subsequently characterised based on compression loading (600 N up to 900 N) and screw designs (conventional and locking) with different penetration depths (unicortical and bicortical). Strain theory was used to evaluate the stability of the model. The correlation of screw configuration with screw type shows a unicortical depth for both types (p < 0.01) for 700 N and 800 N loads and (p < 0.05) for configurations 134 and 124. Interfragmentary strain affected only the 600 N load (p < 0.01) for the bicortical conventional type (group BC), and the screw configurations that were influenced were 1234 and 123 (p < 0.05). The low steepness of the slope indicates the least εIFM for the corresponding biomechanical characteristic in good-quality stability. A strain value of ≤2% promotes callus formation and is classified as absolute stability, which is the minimum required value for the induction of callus and the maximum value that allows bony bridging. The outcomes have provided the correlation of screw configuration in femoral midshaft transverse fracture implantation which is important to promote essential primary stability.
Surgeons face a significant challenge due to the heat generated during drilling, as excessive temperatures at the bone–tool interface can lead to irreversible damage to the regenerative soft tissue and result in thermal osteonecrosis. While previous studies have explored the use of machine learning to predict the temperature rise during bone drilling, this in vitro study introduces a comprehensive approach by combining the Response Surface Methodology (RSM) with advanced machine learning techniques. The main objective lies in the comprehensive evaluation and comparison of support vector machine (SVM) and random forest (RF) models specifically for the optimization of the bone drilling parameters to prevent thermal bone necrosis. A total of 27 experiments were conducted using a multi-level factorial method, with analysis performed via the Minitab software version 19.1. Performance metrics such as the mean squared error (MSE), mean absolute percentage error (MAPE), and coefficient of determination (R2) were used to assess model accuracy. The RF model emerged as the most effective, with R2 values of 94.2% for testing and 97.3% for training data, significantly outperforming other models in predicting temperature fluctuations. This study demonstrates the superior predictive capabilities of the RF model and offers a robust framework for the optimization of surgical procedures to mitigate the risk of thermal damage.
This paper presents the extensions of newly developed finite element (FE) formulation to evaluate fracture behavior of parallel edge cracks problems. The numerical formulation used Barsoum singular finite elements to compute fracture parameters in two dimensional finite element models subjected to different crack-width ratio and cracks interval ratio. Mixed mode stress intensity factors (SIFs) of parallel edge cracks are computed in extending of FE formulation for pure Mode I formulation proposed by authors. In 2D linear elastic problem under mixed mode condition, the variation of SIF value near crack tips are discussed comprehensively. The newly finite element formulations are resulted with remarkable agreement with energy release rate based method compared to analytical solution available in the literatures.
5 May 2024 in Journal of Advanced Research in Applied Mechanics
This study aimed to elucidate the influences of several drilling parameters on bone temperature during drilling, as excessive heat generation can cause thermal bone damage and affect post-surgery recovery. In vitro drilling tests were conducted on bovine femoral shaft cortical bone specimens. The parameters considered included tool rotational speed (s), feed rate (f), tool diameter (d), and drill tip angles of 118° and 135°. Drilling temperatures were studied across a range of 800–2000 rpm rotational speeds, 20–40 mm/min feed rates, and 2–4 mm drill diameters. A predictive statistical model was constructed using the response surface methodology (RSM). Analysis of variance (ANOVA) at a 95% confidence level (α = 0.05) revealed that rotational speed significantly impacted temperature increase, contributing to 59.74% of observed temperature rises. Drill diameter accounted for 16.21% of temperature variations, while feed rate contributed to 10.04% of the temperature rises. The study provides valuable insights into the predominant factors affecting bone temperature during drilling. Understanding these parameters and their interplay is pivotal for optimizing drilling conditions and minimizing potential thermal damage to bones.
2 June 2024 in Journal of Advanced Research in Applied Mechanics
The robustness of dental implant systems in the context of occlusal restoration relies significantly on biomechanical factors associated with the imposition of excessive loads. These factors encompass the macro geometries of the implants, bone qualities, parafunctional oral habits, and specific materials employed. The choice of different implant lengths in different bone qualities may give rise to distinct effects on the way loads are distributed across the interface between the implant and the adjacent bone. As of now, the influence of implant length and bone quality on the surrounding tissues and the stability of implant structure continues to be a matter of debate and uncertainty, particularly in situations involving the possibility of implant failure. This study employed three-dimensional finite element analysis to investigate five distinct implant lengths (4, 6, 10, 13, and 15 mm) in two types of bone quality (type II and III). The bone tissues were characterized through the utilization of computed tomography image datasets and then underwent processing within the SolidWorks software. All geometric configurations were transformed into finite element models, which were subjected to analysis within the ANSYS software. Anisotropic and isotropic properties were attributed to the bone and implant models, respectively. A dynamic occlusal loading quantified at 300 N was applied to the implant body, accompanied by a pre-tension force of 20 N on the screw component. The longer implants exhibited decreased stress magnitudes in type II bone (87.86 – 36.66 MPa) and increased stress magnitudes in type III bone (80.5 – 2128.9 MPa) within the surrounding bone tissue, in comparison to the shorter implants. However, stress within the implant body was generally elevated with the use of longer implants in both bone types (type II: 505.32 – 625.35 MPa; type III: 500.45 – 2186.7 MPa). Irrespective of bone quality, the longer implants predominantly led to lower bone strain levels (type II: 0.006828 – 0.003328; type III: 0.054250 – 0.021678) and overall deformation of the implant-abutment assembly (type II: 0.1458 – 0.1348 μm; type III: 0.1754 – 0.1492 μm) compared to their shorter counterparts. Among all the assessed findings, type III bone displayed a more pronounced adverse impact on the biomechanical responses of the dental implant and neighbouring bone except for the implant stresses under the applied physiological loading.