Jorge Mateo

Prof. Dr. Jorge Mateo


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2021 in Electronics
Verified
Journal Article
Open access
PDF file
MLMiguel Ángel Luján
Miguel Ángel Luján
María Verónica Jimeno JiménezMaría Verónica Jimeno Jiménez
María Verónica Jimeno Jiménez
Jorge MateoJorge Mateo
Jorge Mateo
JRJorge J. Ricarte
Jorge J. Ricarte
Alejandro L. BorjaAlejandro L. Borja
Alejandro L. Borja
In this paper, a general overview regarding neural recording, classical signal processing techniques and machine learning classification algorithms applied to monitor brain activity is presented. Currently, several approaches classified as electrical, magnetic, neuroimaging recordings and brain stimulations are available to obtain neural activity of the human brain. Among them, non-invasive methods like electroencephalography (EEG) are commonly employed, as they can provide a high degree of temporal resolution (on the order of milliseconds) and acceptable space resolution. In addition, it is simple, quick, and does not create any physical harm or stress to patients. Concerning signal processing, once the neural signals are acquired, different procedures can be applied for feature extraction. In particular, brain signals are normally processed in time, frequency, and/or space domains. The features extracted are then used for signal classification depending on its characteristics such us the mean, variance or band power. The role of machine learning in this regard has become of key importance during the last years due to its high capacity to analyze complex amounts of data. The algorithms employed are generally classified in supervised, unsupervised and reinforcement techniques. A deep review of the most used machine learning algorithms and the advantages/drawbacks of most used methods is presented. Finally, a study of these procedures utilized in a very specific and novel research field of electroencephalography, i.e., autobiographical memory deficits in schizophrenia, is outlined.

18 August 2024 in Healthcare
Verified
Journal Article
Open access
PDF file
RGRaquel Gómez-Molina
Raquel Gómez-Molina
Miguel Suárez MatíasMiguel Suárez Matías
Miguel Suárez Matías
RMRaquel Martínez Martínez
Raquel Martínez Martínez
MSMARIFINA CHILET SÁEZ SÁEZ
MARIFINA CHILET SÁEZ SÁEZ
JBJosep Miquel Bauça
Josep Miquel Bauça
Jorge MateoJorge Mateo
Jorge Mateo
Colorectal cancer (CRC) is a significant global health issue where early detection is crucial for improving treatment outcomes and survival rates. This comprehensive review assesses the utility of stool-based tests in CRC screening, including traditional fecal occult blood tests (FOBT), both chemical (gFOBT) and immunochemical techniques (FIT), as well as multitarget stool DNA (mt-sDNA) as a novel and promising biomarker. The advancements, limitations and the impact of false positives and negatives of these methods are examined. The review analyzed various studies on current screening methods, focusing on laboratory tests and biomarkers. Findings indicate that while FIT and mt-sDNA tests offer enhanced sensitivity and specificity over traditional guaiac-based FOBT, they also come with higher costs and potential for increased false positives. FIT shows better patient adherence due to its ease to use, but incorrect usage and interpretation of FOBT can lead to significant diagnostic errors. In conclusion, despite the improvements in FOBT methods like FIT in CRC detection, careful consideration of each method’s benefits and drawbacks is essential. Effective CRC screening programs should combine various methods tailored to specific population needs, aiming for early detection and reduced mortality rates.

Verified
Journal Article
Open access
PDF file
CSCarmen Soria
Carmen Soria
Yoel ArroyoYoel Arroyo
Yoel Arroyo
ANA MARÍA TORRES ARANDAANA MARÍA TORRES ARANDA
ANA MARÍA TORRES ARANDA
Miguel Redondo DuqueMiguel Redondo Duque
Miguel Redondo Duque
CBChristoph Basar
Christoph Basar
Jorge MateoJorge Mateo
Jorge Mateo
Schizophrenia is a chronic and severe mental disorder that affects individuals in various ways, particularly in their ability to perceive, process, and respond to stimuli. This condition has a significant impact on a considerable number of individuals. Consequently, the study, analysis, and characterization of this pathology are of paramount importance. Electroencephalography (EEG) is frequently utilized in the diagnostic assessment of various brain disorders due to its non-intrusiveness, excellent resolution and ease of placement. However, the manual analysis of electroencephalogram (EEG) recordings can be a complex and time-consuming task for healthcare professionals. Therefore, the automated analysis of EEG recordings can help alleviate the burden on doctors and provide valuable insights to support clinical diagnosis. Many studies are working along these lines. In this research paper, the authors propose a machine learning (ML) method based on the eXtreme Gradient Boosting (XGB) algorithm for analyzing EEG signals. The study compares the performance of the proposed XGB-based approach with four other supervised ML systems. According to the results, the proposed XGB-based method demonstrates superior performance, with an AUC value of 0.94 and an accuracy value of 0.94, surpassing the other compared methods. The implemented system exhibits high accuracy and robustness in accurately classifying schizophrenia patients based on EEG recordings. This method holds the potential to be implemented as a valuable complementary tool for clinical use in hospitals, supporting clinicians in their clinical diagnosis of schizophrenia.

23 January 2012 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
Jorge MateoJorge Mateo
Jorge Mateo
José J. RietaJosé J. Rieta
José J. Rieta
The electrocardiogram (ECG) is the most widely used method for diagnosis of heart diseases, where a good quality of recordings allows the proper interpretation and identification of physiological and pathological phenomena. However, ECG recordings often have interference from noises including thermal, muscle, baseline and powerline noises. These signals severely limit ECG recording utility and, hence, have to be removed. To deal with this problem, the present paper proposes an artificial neural network (ANN) as a filter to remove all kinds of noise in just one step. The method is based on a growing ANN which optimizes both the number of nodes in the hidden layer and the coefficient matrices, which are optimized by means of the Widrow–Hoff delta algorithm. The ANN has been trained with a database comprising all kinds of noise, both from synthesized and real ECG recordings, in order to handle any noise signal present in the ECG. The proposed system improves results yielded by conventional techniques of ECG filtering, such as FIR-based systems, adaptive filtering and wavelet filtering. Therefore, the algorithm could serve as an effective framework to substantially reduce noise in ECG recordings. In addition, the resulting ECG signal distortion is notably more reduced in comparison with conventional methodologies. In summary, the current contribution introduces a new method which is able to suppress all ECG interference signals in only one step with low ECG distortion and a high noise reduction.

1 December 2019 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Closed access
FEFredy A. Escobar-Ipuz
Fredy A. Escobar-Ipuz
CSCarmen Soria-Bretones
Carmen Soria-Bretones
MGMaría A. García-Jiménez
María A. García-Jiménez
ECElisa M. Cueto
Elisa M. Cueto
AAAna M. Torres Aranda
Ana M. Torres Aranda
Jorge MateoJorge Mateo
Jorge Mateo

1 September 2013 in IET Signal Processing
Verified
Journal Article
Open access
PDF file
Jorge MateoJorge Mateo
Jorge Mateo
ATAna Maria Torres
Ana Maria Torres
MGMaría A. García
María A. García
The electroencephalogram (EEG) signal is the manifestation of brain activity recorded as changes in electrical potentials at multiple locations over the scalp and it can be distorted by many other sources of electrical activity, called eye artefacts. It is important to remove these artefact signals before analysing the EEG signal, to obtain accurate information about brain activity and avoid mistakes in its interpretation. To deal with this problem, the present study proposes an artificial neural network, as a filter to remove ocular artefacts. In the proposed method, the number of radial basis function (RBF) neurons and input output space clustering are adaptively determined. Furthermore, the structure of the system and the parameters of the corresponding RBF units are trained automatically and relatively fast adaptation is attained. By the least‐square error estimator techniques, the proposed system is suitable for real EEG applications. The proposed system improves results yielded by conventional techniques of ocular reduction, such as principal component analysis, support vector machines and independent component analysis systems. As a consequence, the algorithm could serve as an effective framework to reduce substantially eye interference in EEG recordings.