The electric power grid wide-area monitoring system (WAMS) has been extended from the transmission to distribution level. As the first WAMS deployed at the distribution level, the frequency monitoring network FNET/GridEye uses global positioning system-time-synchronized monitors, called frequency disturbance recorders, to capture dynamic grid behaviors. In this paper, the latest developments of monitor design and the state-of-the-art data analytics applications of FNET/GridEye are introduced. Its innovations and uniqueness are also discussed. Thanks to its low cost, easy installation, and multifunctionalities, FNET/GridEye works as a cost-effective situational awareness tool for power grid operators and pioneers the development of WAMS in electric power grids.
Despite its wide applications in power grid monitoring, the classic discrete Fourier transform (DFT)-based synchrophasor estimation algorithms suffer from significant errors when the power system operates under off-nominal frequency conditions. This phenomenon is caused by spectral leakage of DFT and becomes even more severe for single-phase synchrophasor estimation. To address this issue, a theory to eliminate the spectral leakage-caused errors is proposed and a Clarke transformation-based DFT synchrophasor estimation algorithm is proposed to implement the theory in this paper. The Clarke transformation constructs a second signal that has exactly 90° phase angle difference from the original single-phase input signal and helps eliminate the estimation errors for a wide frequency range. The proposed algorithm is tested under the conditions required in the phasor measurement unit standard C37.118.1-2011 and C37.118.1a-2014, as well as the harmonic and noise conditions not required in the standard to verify its performance. More importantly, the idea of using Clarke transformation can be used for other DFT-based synchrophasor algorithms in order to achieve higher synchrophasor measurement accuracy under dynamic conditions. An example is presented at last to demonstrate the expandability of the proposed idea.
With the aid of global positioning system (GPS), synchronized measurement devices (SMDs) are increasingly deployed across power systems to monitor the status of electric grids by providing accurate measurement data along with unified time stamps. Unfortunately, GPS receivers tend to lose signal lock when certain uncontrollable and unpredictable factors arise. In order to investigate the presence of GPS signal loss (GSL) issues on measurement devices, analysis is performed on historical data from both phasor data concentrators and FNET/GridEye servers. Meanwhile, the impact of GSL on field measurement accuracy has not been previously explored in depth. Through analysis and experimental tests, this paper discovers angle drift caused by GSL, which consequently leads to the total vector error exceeding the IEEE standard C37.118.1-2011. Furthermore, a compensation method is proposed to rectify the angle drift and laboratory experiments demonstrate that the proposed method does effectively reduce angle drift and mitigate the impact of GSL in SMDs.
The increase of renewable penetration in power grids calls for loads to participate in frequency regulation to avoid under-frequency load shedding after large resource contingencies. The motivation of this paper is to fulfill a fast residential load control for frequency stability enhancement. For this purpose, a novel mobile distribution-level phasor measurement unit (MDPMU) is developed for disturbance event detection, power mismatch estimation and fast load control. First, the systematic design of the MDPMU introduced. The proposed MDPMU has the major advantages of low cost and high frequency measurement accuracy. Second, the distribution-level measurement is utilized for the rate of change of frequency (ROCOF) calculation. Upon detection of a power system frequency event, power mismatch is estimated at the early stage of the event. Details of a robust approach to calculate ROCOF and determine the event starting point are presented. Practical issues including the measurement reporting rate and estimation time are also considered. Last, with the proposed control system, residential load responses can be controlled coordinately based on load availability and compensation prices offered by customers, providing adaptive frequency regulation service after large resource contingencies. The accuracy of frequency measurement and power mismatch estimation are evaluated via experimental analysis. The frequency stability improvement by load control is validated via PSS/E simulation.
27 February 2015 in IEEE Transactions on Smart Grid
This paper proposes a method for estimating synchronized phase and frequency at the distribution level under both steady-state and dynamic conditions. The discrete Fourier transform-based method is widely used for phasor and frequency estimation, thanks to its low computational burden. However, errors arise when the power system is operating at off-nominal frequency, especially under dynamic conditions such as phase modulation. Additionally, the power grid signal at the distribution level contains more noise and harmonics, which cause phase and frequency estimation errors. In this paper, a synchronized phase and frequency estimation algorithm suitable for measurement at the distribution level is proposed and tested under noise and harmonic conditions, as well as various conditions in the phasor measurement unit Standard (C37.118.1-2011 and C37.118.1a-2014), to verify its measurement accuracy at the distribution level.
8 February 2016 in IEEE Transactions on Power Delivery
Global positioning system (GPS)-based phasor measurement units (PMUs) are increasingly deployed in the power system in order to monitor the grid status in real time. Nevertheless, GPS receivers inside PMUs tend to lose signal lock when certain uncontrollable and unpredictable factors arise. To address this issue, the chip-scale atomic clock is proposed to be used as a backup solution for time synchronization in this paper. It is the first time ever reporting the utilization of CSAC in the electric power grid. Test results show that CSAC can work as a reliable and accurate backup for GPS timing.