Ting ZHU

Ms. Ting ZHU

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
JHJianping Hu
Jianping Hu
TZTing ZHU
Ting ZHU
JHJianlin Hu
Jianlin Hu
ZFZhen Fang
Zhen Fang
RZRuihe Zhang
Ruihe Zhang
Due to micro landforms and climate, the 110 kV transmission lines crossing the mountain areas are exposed to severe icing conditions for both their high voltage (HV) conductors and shield wires during the winter. Ice accumulation on the shield wire causes excessive sag, which leads to a reduced clearance between earth and HV wires, and could eventually result in tripping of the line due to phase-to-ground flashover. Due to the lack of effective de-icing techniques for the shield wires, removing them completely from the existing overhead line (OHL) structure becomes a reasonable solution to prevent icing accidents. Nevertheless, the risk of exposure to lightning strikes increased significantly after the shield wires were removed. In order to cope with this, the anti-thunder and anti-icing composite insulator (AACI) is installed on the OHLs. In this article, the 110 kV transmission line without shield wire is considered. The shielding failure after installation of the AACIs is studied using the lightning strike simulation models established in the ATP software. The lightning stroke flashover tests are carried out to examine the shielding failures on various designs for the AACIs. Assuming the tower’s earth resistance is 30 Ω, the LWL of back flashover and direct flashover are 630.88 kA and 261.33 kA, respectively, after the installation of AACIs on an unearthed OHL. Due to the unique mechanism of the AACI, the operational voltage level and the height of the pylon have a neglectable influence on its lightning withstand level (LWL). When the length of the parallel protective gap increases from 450 mm to 550 mm, the lightning trip-out rate decreases from 0.104 times/100 km·a to 0.014 times/100 km·a, and the drop rate reaches 86.5%. Therefore, increasing the gap distance for the AACI to provide additional clearance is proven to be an effective method to reduce the shielding failure rates for non-shield-wired OHLs.

23 October 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
ZWZijia Wang
Zijia Wang
JHJianlin Hu
Jianlin Hu
MWMENG Wei
MENG Wei
PQPeiyu Qin
Peiyu Qin
TZTing ZHU
Ting ZHU
Xingliang JiangXingliang Jiang
Xingliang Jiang
Accurate calculation of physical parameters for an ice surface arc is fundamental to numerical research, with particle composition being a critical factor. This paper introduces a linear dimensionality reduction technique to address the challenges posed by complex internal arc reactions in calculating particle composition. The method’s accuracy is validated by comparing the computed electron number density of the arc on the ice surface with the results of the emission spectrum. By combining the types particles present in the arc on the ice surface identified by emission spectroscopy, this study analyses how varying NaCl and H 2 O ratios affect the number density of charged particles in the arc. Results indicate that NaCl significantly increases the charged particle density in the arc, with a peak observed between the temperature range of 5000K to 7000K, which shifts to higher temperatures as the proportion of NaCl rises. Conversely, H 2 O inhibits the rise in the number density of charged particles in the arc within the 3000K to 8200K range, with stronger inhibition as the H 2 O proportion increases.