Metal-oxide arresters (MOAs) are used to absorb the electrical energy resulting from overvoltages in power systems. However, temperature rises caused by the absorbed energy can lead to the electrothermal failure of MOAs. Therefore, it is necessary to analyze the electric and thermal characteristics of MOAs. In this paper, in order to study the electric and thermal characteristics of MOAs under power frequency voltage, an improved electrothermal model of an MOA is presented. The proposed electrothermal model can be divided into an electric model and a thermal model. In the electric model, based on the conventional MOA electric circuit, the effect of temperature on the voltage–current (V–I) characteristics of an MOA has been obtained. Using temperature and applied voltage as input data, the current flows through the MOA can be calculated using the artificial neural network (ANN) method. In the thermal model, the thermal circuit of a MOA has been built. The varistor power loss obtained from the electric model is used as input data, and the temperature of the zinc oxide varistors can be calculated. Therefore, compared with the existing MOA models, the interaction of leakage current and temperature can be considered in the proposed model. Finally, experimental validations have been done, and the electrothermal characteristics of an MOA have been studied by simulation and experimental methods. The electrothermal model proposed in this paper can assist with the prediction of the electric and thermal characteristics of MOAs.
21 January 2021 in IEEE Transactions on Power Delivery
Lightning strikes and pollution could cause short circuits and tripping of the overhead distribution lines. To alleviate this, a 10-kV post insulator with concentric externally gapped line arrester (EGLA) has been proposed and its performance is studied in service. However, its pollution performance has to be established. This paper studies the AC pollution breakdown characteristics of the EGLA and broaden current knowledge of pollution flashover. Compared with the flashover of the normal insulator, three kinds of specificity of the EGLA were found. Firstly, the pollution flashover process can be divided into three categories. Secondly, the wet flashover voltage, Uf_wet , of the novel insulator is higher than the dry flashover voltage, Uf_dry . Thirdly, the piecewise fitting methods with a × ESDD^ −b + d and a × ESDD^ −b + c × ESDD^ −d are more suitable for fitting the empirical formula of flashover voltage. Furthermore, to explain specificity, the electric potential and electric field distribution are calculated based on the finite element method. Calculated results indicate that when the EGLA is covered with a 0.5mm water film, the maximum electric field intensity decreased from 2.17 kV/cm to 1.99 kV/cm. Also, U _arrester (the withstand voltage of the insulation section) was obtained from the tests and it presents a discontinuous and random increasing trend until flashover occurs, which is considered to be one of the important reasons for the specificity. Besides, based on the Obenaus’ model and Hampton's criterion, we further analyzed the arc development process by a simplified plate model.
Due to micro landforms and climate, the 110 kV transmission lines crossing the mountain areas are exposed to severe icing conditions for both their high voltage (HV) conductors and shield wires during the winter. Ice accumulation on the shield wire causes excessive sag, which leads to a reduced clearance between earth and HV wires, and could eventually result in tripping of the line due to phase-to-ground flashover. Due to the lack of effective de-icing techniques for the shield wires, removing them completely from the existing overhead line (OHL) structure becomes a reasonable solution to prevent icing accidents. Nevertheless, the risk of exposure to lightning strikes increased significantly after the shield wires were removed. In order to cope with this, the anti-thunder and anti-icing composite insulator (AACI) is installed on the OHLs. In this article, the 110 kV transmission line without shield wire is considered. The shielding failure after installation of the AACIs is studied using the lightning strike simulation models established in the ATP software. The lightning stroke flashover tests are carried out to examine the shielding failures on various designs for the AACIs. Assuming the tower’s earth resistance is 30 Ω, the LWL of back flashover and direct flashover are 630.88 kA and 261.33 kA, respectively, after the installation of AACIs on an unearthed OHL. Due to the unique mechanism of the AACI, the operational voltage level and the height of the pylon have a neglectable influence on its lightning withstand level (LWL). When the length of the parallel protective gap increases from 450 mm to 550 mm, the lightning trip-out rate decreases from 0.104 times/100 km·a to 0.014 times/100 km·a, and the drop rate reaches 86.5%. Therefore, increasing the gap distance for the AACI to provide additional clearance is proven to be an effective method to reduce the shielding failure rates for non-shield-wired OHLs.
As a result of lightning strikes, pollution, and ice, overhead distribution wires might be short-circuited and trip. As a result, researchers have developed a new lightning protection composite insulator. There is still a need to test its pollution and icing performance. Based on the finite element and field test method, this paper studies the electric field distribution and AC (Alternating Current) breakdown characteristics of polluted novel lightning protection insulators under icing conditions. Firstly, the finite element calculated results show that this novel insulator’s electric field distribution is different from that of a conventional insulator. The locations with sizeable electric fields are located in the insulation section, and the electric field in the arrester section is tiny. In addition, when the insulator surface is covered with ice, there is an increase in the electric field along the surface and pin electrodes. Compared with the dry conditions, when there is an ice layer and icicle, electric field peaks increase by 48.85% and 46.08%, respectively. Secondly, the test results show that there are three types of arc paths in different pollution levels. The arc paths are related to ESDD (equivalent salt deposit density) under icing conditions. Uf shows a downward trend with increased pollution levels, and the maximum flashover voltage is 2.70 times more than the minimum. Finally, four fitting methods are proposed in this paper. After comparing the goodness of fit of different functions, the quadratic function and negative power function with the constant term are recommended as empirical formulas for calculating flashover voltage of novel insulators under icing conditions in different pollution levels. The research results of this paper have a specific guiding role for the selection of the external insulation of transmission lines and structural optimization of novel insulators.
According to operational experience of power systems, the outdoor insulation strength can be reduced due to the effect of rain. Till now, little work has been done to investigate the flashover performance of air gapped arresters under rain conditions. Therefore, in this paper, experiments were carried out and the AC flashover performance of 10 kV arresters with different air gap structures was studied. The experimental results show that, for the tested arresters, the flashover current mainly flows through the air gaps and zinc oxide varistors under rain conditions. It is also confirmed that the flashover voltages decrease with the increasing of rain intensity and conductivity. In the windward direction, the wind can distort the water streams between the air gaps and rise the flashover voltages. In the leeward direction, if the rod electrode is beyond the range of the plane electrode, the flashover voltage researches the smallest value when the wind speed is 4 m/s. Analysis and discussions have been done to explain the experimental results, and the research in this paper may provide reference to improve the flashover performance of air gapped arresters under rain conditions.