Anurag Adiraju

Mr. Anurag Adiraju


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Olfa KanounOlfa Kanoun
Olfa Kanoun
Tamara Lazarevic-PastiTamara Lazarevic-Pasti
Tamara Lazarevic-Pasti
Igor PastiIgor Pasti
Igor Pasti
Salem NasraouiSalem Nasraoui
Salem Nasraoui
MTMalak Talbi
Malak Talbi
AAAmmar Al-Hamry
Ammar Al-Hamry
Electrochemical sensors play a significant role in detecting chemical ions, molecules, and pathogens in water and other applications. These sensors are sensitive, portable, fast, inexpensive, and suitable for online and in-situ measurements compared to other methods. They can provide the detection for any compound that can undergo certain transformations within a potential window. It enables applications in multiple ion detection, mainly since these sensors are primarily non-specific. In this paper, we provide a survey of electrochemical sensors for the detection of water contaminants, i.e., pesticides, nitrate, nitrite, phosphorus, water hardeners, disinfectant, and other emergent contaminants (phenol, estrogen, gallic acid etc.). We focus on the influence of surface modification of the working electrodes by carbon nanomaterials, metallic nanostructures, imprinted polymers and evaluate the corresponding sensing performance. Especially for pesticides, which are challenging and need special care, we highlight biosensors, such as enzymatic sensors, immunobiosensor, aptasensors, and biomimetic sensors. We discuss the sensors’ overall performance, especially concerning real-sample performance and the capability for actual field application.

6 December 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Aseel AlnaimiAseel Alnaimi
Aseel Alnaimi
AAAmmar Al-Hamry
Ammar Al-Hamry
YMYahia Makableh
Yahia Makableh
AAAnurag Adiraju
Anurag Adiraju
Olfa KanounOlfa Kanoun
Olfa Kanoun
Prostate cancer is one of the most frequently diagnosed male malignancies and can be detected by prostate-specific antigen (PSA) as a biomarker. To detect PSA, several studies have proposed using antibodies, which are not economical and require a long reaction time. In this study, we propose to use self-assembled thiolated single-strand DNA on electrodes functionalized by multi-walled carbon nanotubes (MWCNT) modified with gold nanoparticles (AuNPs) to realize a low-cost label-free electrochemical biosensor. In this regard, the PSA aptamer was immobilized via electrostatic adsorption on the surface of a screen-printed MWCNT/AuNPs electrode. The immobilization process was enhanced due to the presence of Au nanoparticles on the surface of the electrode. Surface characterization of the electrode at different stages of modification was performed by electrochemical impedance spectroscopy (EIS), atomic force microscopy (AFM) and Fourier transform infrared spectroscopy (FTIR) and contact angle for surface tension properties. The results showed an increase in surface roughness due to the absorbance of the aptamer on the electrode surfaces. The developed sensor has an extended linear range of 1–100 ng/mL, and a very low limit of detection down to 1 pg/mL. In addition, the reaction has a binding time of only five minutes on the developed electrodes. Investigations of the biosensor selectivity against several substances revealed an efficient selectivity for PSA detection. With this approach, low-cost biosensors with high sensitivity can be realized which have a wide linearity range and a low limit of detection, which are necessary for the early detection of prostate cancer.

11 January 2022 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
DRDHIVAKAR RAJENDRAN
DHIVAKAR RAJENDRAN
RRRajarajan Ramalingame
Rajarajan Ramalingame
AAAnurag Adiraju
Anurag Adiraju
HNHanen Nouri
Hanen Nouri
Olfa KanounOlfa Kanoun
Olfa Kanoun
Dispersion of carbon nanotubes (CNT) in solvents and/or polymers is essential to reach the full potential of the CNTs in nanocomposite materials. Dispersion of CNTs is especially challenging due to the van-der-Waals attraction forces between the CNTs, which let them tend to re-bundle and/or re-aggregate. This paper presents a brief analysis of the quality and stability of functionalized multiwalled carbon nanotubes (fMWCNT) dispersion on polar solvents. A comparative study of functionalized CNT dispersion in water, methyl, and alcohol-based organic solvents has been carried out and the dispersion has been characterized by UV-VIS spectroscopy, electrochemical characterization such as cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Visual analysis of the dispersion has been investigated for up to 14 days to assess the dispersion’s stability. Based on the material characterization, it was observed that the degree of affinity fMWCNT with -COOH group highly depends on the polarity of the solvent, where the higher the polarity, the better the interaction of fMWCNT with solvents.

15 December 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
Tianqi LuTianqi Lu
Tianqi Lu
AAAmmar Al-Hamry
Ammar Al-Hamry
JRJose Mauricio Rosolen
Jose Mauricio Rosolen
ZHZheng Hu
Zheng Hu
Jun-Feng HaoJun-Feng Hao
Jun-Feng Hao
Olfa KanounOlfa Kanoun
Olfa Kanoun
We investigated functionalized graphene materials to create highly sensitive sensors for volatile organic compounds (VOCs) such as formaldehyde, methanol, ethanol, acetone, and isopropanol. First, we prepared VOC-sensitive films consisting of mechanically exfoliated graphene (eG) and chemical graphene oxide (GO), which have different concentrations of structural defects. We deposited the films on silver interdigitated electrodes on Kapton substrate and submitted them to thermal treatment. Next, we measured the sensitive properties of the resulting sensors towards specific VOCs by impedance spectroscopy. We obtained the eG- and GO-based electronic nose composed of two eG films- and four GO film-based sensors with variable sensitivity to individual VOCs. The smallest relative change in impedance was 5% for the sensor based on eG film annealed at 180 °C toward 10 ppm formaldehyde, whereas the highest relative change was 257% for the sensor based on two-layers deposited GO film annealed at 200 °C toward 80 ppm ethanol. At 10 ppm VOC, the GO film-based sensors were sensitive enough to distinguish between individual VOCs, which implied excellent selectivity, as confirmed by Principle Component Analysis (PCA). According to a PCA-Support Vector Machine-based signal processing method, the electronic nose provided identification accuracy of 100% for individual VOCs. The proposed electronic nose can be used to detect multiple VOCs selectively because each sensor is sensitive to VOCs and has significant cross-selectivity to others.


26 April 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
AAAmmar Al-Hamry
Ammar Al-Hamry
Tianqi LuTianqi Lu
Tianqi Lu
HCHaoran Chen
Haoran Chen
AAAnurag Adiraju
Anurag Adiraju
Salem NasraouiSalem Nasraoui
Salem Nasraoui
Olfa KanounOlfa Kanoun
Olfa Kanoun
In this paper, the relative humidity sensor properties of graphene oxide (GO) and graphene oxide/multiwalled nanotubes (GO/MWNTs) composites have been investigated. Composite sensors were fabricated by direct laser scribing and characterized using UV-vis-NIR, Raman, Fourier transform infrared, and X-ray photoemission spectroscopies, electron scanning microscopy coupled with energy-dispersive X-ray analysis, and impedance spectroscopy (IS). These methods confirm the composite homogeneity and laser reduction of GO/MWNT with dominant GO characteristics, while ISresults analysis reveals the circuit model for rGO-GO-rGO structure and the effect of MWNT on the sensor properties. Although direct laser scribing of GO-based humidity sensor shows an outstanding response (|ΔZ|/|Z| up to 638,800%), a lack of stability and repeatability has been observed. GO/MWNT-based humidity sensors are more conductive than GO sensors and relatively less sensitive (|ΔZ|/|Z| = 163,000%). However, they are more stable in harsh humid conditions, repeatable, and reproducible even after several years of shelf-life. In addition, they have fast response/recovery times of 10.7 s and 9.3 s and an ultra-fast response time of 61 ms when abrupt humidification/dehumidification is applied by respiration. All carbon-based sensors’ overall properties confirm the advantage of introducing the GO/MWNT hybrid and laser direct writing to produce stable structures and sensors.