Hanen Nouri

Ms. Hanen Nouri


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in Journal of Composites Science
Verified
Journal Article
Open access
PDF file
DRDHIVAKAR RAJENDRAN
DHIVAKAR RAJENDRAN
RRRajarajan Ramalingame
Rajarajan Ramalingame
AAAnurag Adiraju
Anurag Adiraju
HNHanen Nouri
Hanen Nouri
Olfa KanounOlfa Kanoun
Olfa Kanoun
Dispersion of carbon nanotubes (CNT) in solvents and/or polymers is essential to reach the full potential of the CNTs in nanocomposite materials. Dispersion of CNTs is especially challenging due to the van-der-Waals attraction forces between the CNTs, which let them tend to re-bundle and/or re-aggregate. This paper presents a brief analysis of the quality and stability of functionalized multiwalled carbon nanotubes (fMWCNT) dispersion on polar solvents. A comparative study of functionalized CNT dispersion in water, methyl, and alcohol-based organic solvents has been carried out and the dispersion has been characterized by UV-VIS spectroscopy, electrochemical characterization such as cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Visual analysis of the dispersion has been investigated for up to 14 days to assess the dispersion’s stability. Based on the material characterization, it was observed that the degree of affinity fMWCNT with -COOH group highly depends on the polarity of the solvent, where the higher the polarity, the better the interaction of fMWCNT with solvents.

4 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AFAhmed Fendri
Ahmed Fendri
AKAhmed Yahia Kallel
Ahmed Yahia Kallel
HNHanen Nouri
Hanen Nouri
HGHamadi GHARIANI
Hamadi GHARIANI
Olfa KanounOlfa Kanoun
Olfa Kanoun
This paper aimed to develop a portable, low-cost, and easy-to-use measurement system for oil quality degradation assessment. The main two chemical parameters affected by frying are the total polar compounds (TPC) and free fatty acids. The system should characterize the change of chemical parameters by measuring the changes in its dielectric parameters. The dielectric parameters, relative permittivity, and conductivity are measured by measuring the capacitance and resistance of a capacitive sensor dipped in oil. The main challenges are that the corresponding changes of the capacitance and resistance are very small and the presence of stray effects. For this reason, the measurement system should be able to detect changes in capacitance and resistance with high resolution and with good immunity to stray effects. The proposed measurement system is based on the conversion of impedance to voltage and time and combining, therefore, having two measurement methods in one circuit. In this way, it is possible to measure the dielectric and resistive parameters and not only the relative permittivity as was done in previous works. The results showed a strong correlation between the chemical and electrical parameters with a coefficient of determination in the range of 0.9.

30 August 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HNHanen Nouri
Hanen Nouri
DRDHIVAKAR RAJENDRAN
DHIVAKAR RAJENDRAN
RRRajarajan Ramalingame
Rajarajan Ramalingame
Olfa KanounOlfa Kanoun
Olfa Kanoun
One of the main challenges during the integration of a carbon/polymer-based nanocomposite sensor on textile substrates is the fabrication of a homogeneous surface of the nanocomposite-based thin films, which play a major role in the reproducibility of the sensor. Characterizations are therefore required in every fabrication step to control the quality of the material preparation, deposition, and curing. As a result, microcharacterization methods are more suitable for laboratory investigations, and electrical methods can be easily implemented for in situ characterization within the manufacturing process. In this paper, several textile-based pressure sensors are fabricated at an optimized concentration of 0.3 wt.% of multiwalledcarbon nanotubes (MWCNTs) composite material in PDMS. We propose to use impedance spectroscopy for the characterization of both of the resistive behavior and capacitive behavior of the sensor at several frequencies and under different loads from 50 g to 500 g. The impedance spectra are fitted to a model composed of a resistance in series with a parallel combination of resistance and a constant phase element (CPE). The results show that the printing parameters strongly influence the impedance behavior under different loads. The deviation of the model parameter α of the CPE from the value 1 is strongly dependent on the nonhomogeneity of the sensor. Based on an impedance spectrum measurement followed by parameter extraction, the parameter α can be determined to realize a novel method for homogeneity characterization and in-line quality control of textile-integrated wearable sensors during the manufacturing process.

28 November 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
AKAhmed Yahia Kallel
Ahmed Yahia Kallel
HNHanen Nouri
Hanen Nouri
TKThomas Keutel
Thomas Keutel
HBHamza Boughanmi
Hamza Boughanmi
AFAmin Fischer
Amin Fischer
Olfa KanounOlfa Kanoun
Olfa Kanoun
In embedded impedance spectroscopy, when the available DC/DC converter in power systems is used to generate excitation signals, a bias current is typically present, leading to unavoidable charging and discharging processes. This violates a crucial condition for impedance spectroscopy, which is to maintain system stability during the measurement, and thus leads to systematic deviations. In this paper, we investigate the stability and characterize the influence of charging/discharging during measurement on the impedance spectrum. Based on this investigation, we propose an excitation sequence followed by a two-step procedure to correct the influence of the unavoidable charging/discharging process and enable a correct impedance spectroscopy measurement. First, the influence of the bias current on the impedance in the diffusion process is identified and neutralized using the distribution of relaxation times, followed by an averaging procedure to minimize the charge state discrepancy between measurement points. The proposed method is validated on a Samsung INR-18650-25R Li-ion battery cell, which was able to provide stable measurements for both 1-quadrant and 2-quadrant settings, with RMS magnitude and phase accuracy of 0.16% and 0.02°, and 0.021% and 0.38°, respectively.

19 October 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HNHanen Nouri
Hanen Nouri
DBDhouha Bouchaala
Dhouha Bouchaala
YZYupei Zhao
Yupei Zhao
AKAhmed Yahia Kallel
Ahmed Yahia Kallel
Olfa KanounOlfa Kanoun
Olfa Kanoun
The Howland current source is widely recognized as a high-efficiency voltage-controlled current source (VCCS) because it delivers a precise and stable current with a high output impedance over a wide frequency bandwidth. The Dual Howland (DH) is distinguished by a relatively high output impedance in comparison to the Enhanced Howland circuit (EH) has therefore the ability to supply higher loads. Nevertheless, at high frequencies, stray capacitances occurring mainly at the input of the operational amplifier and the circuit’s output strongly affect its behavior. The output impedance strongly decreases, especially at frequencies higher than 100 kHz, and the flatness of the output current in dependence on the load is strongly affected. To overcome these challenges, we propose a novel dual Howland current source with load in the loop (DH-LL) completely isolating the load from the ground and maintaining the simplicity of the circuit. A simulation study shows that the output impedance ( Z out ) of the DH-LL remains constant independent of the input stray capacitances. The influence of the output stray capacitance on the relative deviation of the output current decreases from 92 % in the case of DH to 2.7 % in the case of DH-LL. Experimental results show that the DH-LL reaches a frequency bandwidth of up to 5 MHz with a deviation of only 2.32 % for a varying load of up to 10 kΩ. Thereby, the relative deviation of the current amplitude, e. g. at 1 MHz, decreases from 6.98 % for DH to 1.44 % for DH-LL.

8 July 2024 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
FMFrancesca Mancino
Francesca Mancino
HNHanen Nouri
Hanen Nouri
Nicola MoccaldiNicola Moccaldi
Nicola Moccaldi
Pasquale ArpaiaPasquale Arpaia
Pasquale Arpaia
Olfa KanounOlfa Kanoun
Olfa Kanoun
The equivalent electrical circuit approach is explored to improve a bioimpedance-based transducer for measuring the bioavailability of synthetic insulin already presented in previous studies. In particular, the electrical parameter most sensitive to the variation of insulin amount injected was identified. Eggplants were used to emulate human electrical behavior under a quasi-static assumption guaranteed by a very low measurement time compared to the estimated insulin absorption time. Measurements were conducted with the EVAL-AD5940BIOZ by applying a sinusoidal voltage signal with an amplitude of 100 mV and acquiring impedance spectra in the range [1–100] kHz. 14 units of insulin were gradually administered using a Lilly’s Insulin Pen having a 0.4 cm long needle. Modified Hayden’s model was adopted as a reference circuit and the electrical component modeling the extracellular fluids was found to be the most insulin-sensitive parameter. The trnasducer achieves a state-of-the-art sensitivity of 225.90 ml1. An improvement of 223 % in sensitivity, 44 % in deterministic error, 7 % in nonlinearity, and 42 % in reproducibility was achieved compared to previous experimental studies. The clinical impact of the transducer was evaluated by projecting its impact on a Smart Insulin Pen for real-time measurement of insulin bioavailability. The wide gain in sensitivity of the bioimpedance-based transducer results in a significant reduction of the uncertainty of the Smart Insulin Pen. Considering the same improvement in in-vivo applications, the uncertainty of the Smart Insulin Pen is decreased from $4.2~\mu $ l to $1.3~\mu $ l.Clinical and Translational Impact Statement: A Smart Insulin Pen based on impedance spectroscopy and equivalent electrical circuit approach could be an effective solution for the non-invasive and real-time measurement of synthetic insulin uptake after subcutaneous administration.