Background: Gastric motility and accommodation have a critical role in maintaining normal gastrointestinal homeostasis. Different modalities can be adopted to quantify those processes, that is, scintigraphy to measure emptying time and intragastric Barostat for accommodation assessment. However, magnetic resonance imaging (MRI) can assess the same parameters noninvasively without ionizing radiation. Our study aimed to develop a detailed three‐dimensional (3D) MRI model of the stomach to describe gastric volumes, surface areas, wall tension distribution, and interobserver agreement.Methods: Twelve healthy volunteers underwent an MRI protocol of six axial T2‐weighted acquisitions. Each dataset was used to construct a 3D model of the stomach: First, the volumes of the whole stomach, gastric liquid, and air were segmented. After landmark placing, a raw 3D model was generated from segmentation data. Subsequently, irregularities were removed, and the model was divided into compartments. Finally, surface area and 3D geometry parameters (inverse curvatures) were extracted. The inverse curvatures were used as a proxy for wall tension distribution without measuring the intragastric pressure.Key Results: The model was able to describe changes in volume and surface geometry for each compartment with a distinct pattern in response to filling and emptying. The surface tension was distributed nonhomogeneously between compartments and showed dynamical changes at various time points.Conclusion & Inferences: The presented model offers a detailed tool for evaluating gastric volumes, surface geometry, and wall tension in response to filling and emptying and will provide insights into gastric emptying and accommodation in diseases such as diabetic gastroparesis.
To determine the stiffness of the pregnant uterine cervix in vivo. Five women in early pregnancy and six women in late pregnancy were included. The EndoFlip is a 1-m-long probe with a 12-cm-long bag mounted on the tip. The tip of the probe was inserted into the cervical canal. Sensors spaced at 0.5-cm intervals along the probe were used to determine 16 serial cross-sectional areas of the bag. The diameter of the cervical canal could thereby be determined during inflation with up to 50 ml saline solution. Tissue stiffness was calculated from the geometric profiles and the pressure-strain elastic modulus (EP) at each sensor site. Three parts of the cervix were defined: the uterus-near part, the middle and the vaginal part. The EPmax was defined as the highest EP detected along the cervical canal. The EPmax was always found in the middle part of the cervix. The median EPmax was 243 kPa (IQR, 67–422 kPa) for the early pregnant women and 5 kPa (IQR, 4–15 kPa) for those at term. In the early pregnant women the stiffness differed along the cervical length (p<0.05) whereas difference along the cervix was not found for late pregnant women. A positive correlation coefficient (Spearman’s rho) was established between the EPs of the uterus-near and the middle part (0.84), between the vaginal and the middle part (0.81), and between the uterus-near and the vaginal part (0.85). This new method can estimate the stiffness along the cervical canal in vivo. This method may be useful in the clinical examination of the biomechanical properties of the uterine cervix.