Shimaa Rifaat

Dr. Shimaa Rifaat

Department of Restorative Dental Sciences, Imam Abdulrahman bin Faisel university, Ad Dammām, Ash Sharqīyah, Saudi Arabia
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2022 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
SRShimaa Rifaat
Shimaa Rifaat
ARAhmed Rahoma
Ahmed Rahoma
FAFatimah Alkhalifa
Fatimah Alkhalifa
GAGhofran AlQuraini
Ghofran AlQuraini
ZAZahraa Alsalman
Zahraa Alsalman
NTNoha Taymour
Noha Taymour
Objective The current study was designed to assess the bonding strength of EndoSeal MTA and AH Plus sealers after using three irrigation protocols as follows: (1) 17% Ethylenediamine tetraacetic acid, (2) 7% maleic acid, and (3) 37% phosphoric acid. Materials and Methods Push-out bond strength was evaluated for 60 middle root slices of 1-mm thickness each. They were horizontally cut from freshly extracted single-rooted human teeth. A hole in the root canal was made using a carbide round bur of 1.1 mm in diameter in a middle third root slice. Specimens were dipped in 2.5% NaOCl, and then they were grouped into three groups; G1: 17% EDTA, G2: 7% maleic acid, and G3: 37% phosphoric acid as a final irrigant for 3 minutes. Each group was subdivided into two subgroups, according to the type of sealer, either EndoSeal MTA or AH Plus. Statistical Analysis After the full set of the sealer, the bond strength was evaluated with the push-out test by applying a force to each slice using a plunger with a 1-mm diameter. The one-way Tukey's post hoc test, analysis of variance (ANOVA) test, and Student's t-test were utilized to gather data and statistically evaluate it. Results The irrigation protocol used exhibited significant influence on the bond strength of EndoSeal MTA and AH Plus sealers. AH Plus sealer subgroups showed the highest bond strength with 7% maleic acid, followed by 37% phosphoric acid, and 17% EDTA. While in the EndoSeal MTA sealer subgroups, the highest bond strength was shown with the 17% EDTA followed by 7% maleic acid and 37% phosphoric acid, respectively. Conclusion The present study revealed that the type of the final irrigant significantly impacts the bond strength of the sealer used. The AH Plus sealer bond strength was improved by using the 7% maleic acid as a final irrigant. In contrast, the EndoSeal MTA sealer showed the best results with the 17% EDTA as a final irrigant.

24 October 2023 in F1000Research
Verified
Journal Article
Open access
PDF file
SRShimaa Rifaat
Shimaa Rifaat
AAAbdullah Aljami
Abdullah Aljami
TATurki Alshehri
Turki Alshehri
SAShahad T. Alameer
Shahad T. Alameer
AAAlhanoof Aldossary
Alhanoof Aldossary
Noha TaymourNoha Taymour
Noha Taymour
Background: Successful root canal treatment is influenced by the apical extent of root canal preparation and the eventual root canal filling. Achieving the full working length until the apical constriction, which is usually 0.5 – 1 mm shorter than the anatomical apex, is crucial. Electronic apex locators were used to detect the working length more accurately. There are six generations of electronic apex locators in the market. The selection of the appropriate irrigation with each apex locator for accurate working length determination is not fully investigated. Methods: The actual working lengths of 120 freshly extracted human single-rooted teeth were measured and compared with their working lengths using 3rd generation (Root ZX) followed by 6th generation (Raypex 6) apex locators in dry medium, presence of 5.25% sodium hypochlorite, and 2% chlorhexidine, without coronal pre-flaring and after coronal pre-flaring using the same irrigating media. Data were collected, tabulated, and afterward analyzed using one-way ANOVA with post-hoc to evaluate the significant difference in average working length between actual working length, Root ZX, and Raypex 6 apex locator working lengths accuracy. Results: The significant results were shown in roots that were coronally pre-flared and their working lengths were measured in a dry medium using Raypex 6 apex locator. While using the Root ZX apex locator, the most accurate results were shown in roots that were coronally pre-flared and their working lengths were measured while using a chlorhexidine irrigating solution. Conclusions: It is concluded that it is very important to know the specific irrigating medium to be used with each specific electronic apex locator to achieve the most accurate working length results.

24 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DADoaa AlEraky
Doaa AlEraky
ARAhmed Rahoma
Ahmed Rahoma
HAHatem Abuohashish
Hatem Abuohashish
AAAbdullh AlQasser
Abdullh AlQasser
AAAbbas AlHamali
Abbas AlHamali
SRShimaa Rifaat
Shimaa Rifaat
The long-term success of root canal treatment requires the prevention of bacterial leakage between canal walls and root canal obturation. In this study, we compared the leakage of Enterococcus faecalis in thirty single-rooted mandibular premolars divided into three groups. The roots in two experimental groups were obturated using a single-cone obturation technique with two different bio-ceramic sealers (MTA Fillapex and CeraSeal) while the roots in the conventional group were obturated using the lateral condensation technique with an epoxy resin sealer (AH Plus). A bacterial leakage test was carried out using a modified microbial leakage model. In the MTA Fillapex group, 30% of the specimens showed a positive sign for bacterial leakage, while 80% of samples in the CeraSeal group leaked. In the AH Plus group, 50% of specimens had bacterial leakage in the canals. The variation of the average number of days between the groups was not found to be significantly different. Taken together, bio-ceramic sealers with single-cone obturation demonstrated comparable results to the resin-based sealer with lateral condensation technique in terms of sealing efficiency against Enterococcus faecalis. Additionally, MTA Fillapex could provide a better sealing ability than CeraSeal bio-ceramic sealer.

23 May 2023 in F1000Research
Verified
Journal Article
Open access
PDF file
SRShimaa Rifaat
Shimaa Rifaat
AAAbdullah Aljami
Abdullah Aljami
TATurki Alshehri
Turki Alshehri
SAShahad T. Alameer
Shahad T. Alameer
AAAlhanoof Aldossary
Alhanoof Aldossary
Noha TaymourNoha Taymour
Noha Taymour
Background: Successful root canal treatment is influenced by the apical extent of root canal preparation and the eventual root canal filling. Achieving the full working length until the apical constriction, which is usually 0.5 – 1 mm shorter than the anatomical apex, is crucial. Electronic apex locators were used to detect the working length more accurately. There are six generations of electronic apex locators in the market. The selection of the appropriate irrigation with each apex locator for accurate working length determination is not fully investigated. Methods: The actual working lengths of 120 freshly extracted human single-rooted teeth were measured and compared with their working lengths using 3rd generation (Root ZX) followed by 6th generation (Raypex 6) apex locators in dry medium, presence of 5.25% sodium hypochlorite, and 2% chlorhexidine, without coronal pre-flaring and after coronal pre-flaring using the same irrigating media. Data were collected, tabulated, and afterward analyzed using one-way ANOVA with post-hoc to evaluate the significant difference in average working length between actual working length, Root ZX, and Raypex 6 apex locator working lengths accuracy. Results: The significant results were shown in roots that were coronally pre-flared and their working lengths were measured in a dry medium using Raypex 6 apex locator. While using the Root ZX apex locator, the most accurate results were shown in roots that were coronally pre-flared and their working lengths were measured while using a chlorhexidine irrigating solution. Conclusions: It is concluded that it is very important to know the specific irrigating medium to be used with each specific electronic apex locator to achieve the most accurate working length results.

29 June 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
AAAli Mohammed Addokhi
Ali Mohammed Addokhi
ARAhmed Rahoma
Ahmed Rahoma
NHNeveen Mokhtar Ayad Hanna
Neveen Mokhtar Ayad Hanna
FAFaisal Alonaizan
Faisal Alonaizan
FFFaraz Farooqi
Faraz Farooqi
SRShimaa Rifaat
Shimaa Rifaat
Introduction: Successful root canal therapy relies on thorough cleaning and disinfection to eliminate microorganisms and residual pulp tissue. Advanced irrigation activation techniques, including Sonic, Ultrasonic, and Diode Laser activation, have improved cleaning efficacy, bacterial reduction, smear layer removal, and irrigant hydrodynamics. On the other hand, these irrigation activation techniques may lead to a temperature rise that may risk the surrounding periodontal tissue. Thus, this study aimed to investigate the temperature rise during different irrigation activation techniques at various time intervals and evaluate the efficacy of these techniques in removing biofilm-mimicking hydrogel BMH of a simulated root canal system in 3D-printed tooth models. Methods: Ten extracted human mandibular premolars, prepared to size 40/0.04 taper, and a hundred 3D-printed resin premolars with simulated main (0.25 mm) and lateral canals (0.15 mm at 3, 7, 11 mm from apex) were used; 50 of them were filled with biofilm-mimicking hydrogel (BMH). Five irrigation activation techniques were evaluated: Diode Laser, Ultrasonic, Sonic, XP-Finisher, and Control (n = 10). Temperature rises were measured on the extracted premolars after 30 and 60 s of activation using a thermographic camera in a controlled environment (23 ± 2 °C). Irrigant penetration, with and without BMH, was assessed in 3D-printed premolars using a 2.5% sodium hypochlorite-contrast medium mixture, visualized with a CMOS radiographic sensor. Penetration was scored (main canal: 3 points; lateral canals: 0–2 points) and analyzed with non-parametric tests. Results: Diode Laser activation technique resulted in the highest temperature rise on the external root surface, followed by the Ultrasonic, with no statistically significant difference observed among the remaining groups. In terms of efficacy, Ultrasonic and Sonic activation achieved significantly greater irrigant penetration in samples without BMH, and greater BMH removal in samples with BMH, compared to Diode Laser, XP-Finisher, and Control groups. Conclusions: In this in vitro study, Diode Laser caused the highest temperature rise, followed by Ultrasonic, with significant increases from 30 to 60 s. Temperature rise did not significantly affect penetration or BMH removal. Ultrasonic and Sonic irrigation techniques achieved the highest depth of penetration (without BMH) and biofilm-mimicking Hydrogel removal (with BMH) compared to Diode Laser, XP-Finisher, and Control.

10 January 2025 in Prosthesis
Verified
Journal Article
Open access
PDF file
Noha TaymourNoha Taymour
Noha Taymour
DADooa I. Alabdrubalameer
Dooa I. Alabdrubalameer
ZSZahra H. Al Shooq
Zahra H. Al Shooq
MYMaram Saud Al Yaseen
Maram Saud Al Yaseen
RZRabab H. Al Zaher
Rabab H. Al Zaher
SRShimaa Rifaat
Shimaa Rifaat
Background: With the growing demand for sustainable dental practices, chitosan has evolved as an eco-friendly disinfectant for polyether impressions. Objectives: The present study investigated the disinfectant efficacy of chitosan on the dimensional accuracy of polyether (PE) impression material. Methods: A total of 63 polyether impressions (ImpregumTM, PentaTM, 3M ESPE, Boca Raton, FL, USA) were prepared from the master 3D-printed model, each consisting of a single unit abutment facing two units’ abutments. Three groups of these subjects were used, while each group comprised 21 impressions, respectively. Group 1 is used as a control group and is not subjected to chemical disinfection. Group 2 is spraying group, in which the PE impressions were sprayed with 0.5% chitosan with a high molecular weight. Group 3 is the immersion group, in which the impression was immersed for 15 min in 0.5% chitosan with a high molecular weight. The data collected were analyzed using SPSS 28.0 and the difference in dimensional accuracy between the groups was measured using a one-way ANOVA. Results: Both the intra-and inter-abutment measurements (MD and OG) showed no statistically significant differences in the dimensional changes between the control and the study groups, while the cross-arch distance showed a statistically significant difference in the dimensional change between control and immersion group, p = 0.000. Conclusions: While chitosan disinfection induced slight dimensional changes in polyether impressions, these alterations remained within clinically acceptable limits. The spray application method appeared to be preferable to immersion, as it resulted in less pronounced dimensional changes.