Neveen Mokhtar Ayad Hanna

Prof. Dr. Neveen Mokhtar Ayad Hanna

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2024 in The Saudi Dental Journal
Verified
Journal Article
Open access
Mohammed GadMohammed Gad
Mohammed Gad
FAFatimah Abdullah Alzaki
Fatimah Abdullah Alzaki
FAFatimah Ahmed Abuwarwar
Fatimah Ahmed Abuwarwar
AAAli Alhammad
Ali Alhammad
MHMohammed Al Hussain
Mohammed Al Hussain
NHNeveen Mokhtar Ayad Hanna
Neveen Mokhtar Ayad Hanna
This study evaluated the influence of various printing layer thicknesses with silicon dioxide nanoparticles (SiO2NPs) incorporated as a reinforcement material on the flexural strength of 3D-printed denture base resins. Asiga (DentaBASE, Asiga, Erfurt, Germany) and NextDent (Denture 3D+, NextDent B.V., Soesterberg, The Netherlands) 3D-printed resins were modified with different concentrations of SiO2NPs (0.25 % and 0.5 wt%). A total of 180 specimens (bar-shaped, 64 × 10 × 3.3 mm) were fabricated (N = 90/resin). Each resin was subdivided into three groups (n = 30) according to the SiO2NP concentration (0 %, 0.25 %, and 0.5 wt%) Each concentration was divided into three groups (n = 10) according to the printing layer thickness (50 µm, 75 µm, and 100 µm). Specimens were printed according to the manufacturer’s instructions and then subjected to 10,000 thermal cycles. A three-point bending test was used to measure the flexural strength (MPa). One-way analysis of variance (ANOVA) and Tukey’s post hoc tests were used to analyze the data (α = 0.05). For both resins, printing layer thicknesses of 50 µm and 75 µm exhibited significantly higher flexural strength than 100 µm (P < 0.001). The 50 µm thickness showed the greatest flexural strength values (81.65 ± 4.77 MPa and 84.59 ± 6.21 MPa for Asiga and NextDent, respectively). The 100 µm thickness showed the lowest flexural strength values (74.35 ± 5.37 and 73.66 ± 5.55 MPa) for Asiga and NextDent, respectively. The flexural strength significantly increased with the addition of SiO2NPs with printing layer thicknesses of 50 µm and 75 µm (P < 0.001), whereas the modified and unmodified groups printed with a 100 µm layer thickness did not differ significantly. Asiga 0.25 %/50 µm and NextDent 0.5 %/50 µm showed the highest flexural strength values (97.32 ± 6.82 MPa and 97.54 ± 7.04 MPa, respectively). Scanning electron microscopy fractured surfaces analysis revealed more lamellae and irregularities with lower printing layer thicknesses and SiO2NP concentrations. The flexural strength increased with printing layer thicknesses of 50 µm or 75 µm combined with SiO2NP reinforcement.

5 July 2023 in Materials
Verified
Journal Article
Open access
PDF file
SFShaimaa Mohamed Fouda
Shaimaa Mohamed Fouda
PEPassent Ellakany
Passent Ellakany
Mohammed GadMohammed Gad
Mohammed Gad
HBHala A. Bahgat
Hala A. Bahgat
NHNeveen Mokhtar Ayad Hanna
Neveen Mokhtar Ayad Hanna
AMAmr A Mahrous
Amr A Mahrous
Occlusal rest provides support for removable partial dentures (RPD). Rest seats are ideally prepared in enamel, but the abutment teeth might be restored or need restorations. This study compared the fracture strength of abutments restored with composite to amalgam restorations after rest seat preparation. Disto-occlusal cavities were prepared in 30 extracted human maxillary premolars. The specimens were allocated in three groups (n = 10) based on the type of restoration. All the specimens were exposed to thermomechanical aging followed by cycling loading. Fracture strength was tested using a universal testing machine, and then, the fracture mode was recorded. The data were analyzed using Kruskal–Wallis test with a significance level set at 0.05. The fracture mode was recorded as catastrophic or non-catastrophic. The fracture strength between all tested groups showed no significant difference. The highest and lowest fracture strength were recorded on amalgam and Tetric N-Ceram groups, respectively. Composite Tetric N-Ceram showed equal distribution of fracture sites on the restorative materials and teeth, it also displayed the highest number of non-catastrophic fractures unlike other groups where the fracture occurred more within the restorations. The fracture strength of composite was comparable to that of amalgam restorations with prepared rest seats.

29 June 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
AAAli Mohammed Addokhi
Ali Mohammed Addokhi
ARAhmed Rahoma
Ahmed Rahoma
NHNeveen Mokhtar Ayad Hanna
Neveen Mokhtar Ayad Hanna
FAFaisal Alonaizan
Faisal Alonaizan
FFFaraz Farooqi
Faraz Farooqi
SRShimaa Rifaat
Shimaa Rifaat
Introduction: Successful root canal therapy relies on thorough cleaning and disinfection to eliminate microorganisms and residual pulp tissue. Advanced irrigation activation techniques, including Sonic, Ultrasonic, and Diode Laser activation, have improved cleaning efficacy, bacterial reduction, smear layer removal, and irrigant hydrodynamics. On the other hand, these irrigation activation techniques may lead to a temperature rise that may risk the surrounding periodontal tissue. Thus, this study aimed to investigate the temperature rise during different irrigation activation techniques at various time intervals and evaluate the efficacy of these techniques in removing biofilm-mimicking hydrogel BMH of a simulated root canal system in 3D-printed tooth models. Methods: Ten extracted human mandibular premolars, prepared to size 40/0.04 taper, and a hundred 3D-printed resin premolars with simulated main (0.25 mm) and lateral canals (0.15 mm at 3, 7, 11 mm from apex) were used; 50 of them were filled with biofilm-mimicking hydrogel (BMH). Five irrigation activation techniques were evaluated: Diode Laser, Ultrasonic, Sonic, XP-Finisher, and Control (n = 10). Temperature rises were measured on the extracted premolars after 30 and 60 s of activation using a thermographic camera in a controlled environment (23 ± 2 °C). Irrigant penetration, with and without BMH, was assessed in 3D-printed premolars using a 2.5% sodium hypochlorite-contrast medium mixture, visualized with a CMOS radiographic sensor. Penetration was scored (main canal: 3 points; lateral canals: 0–2 points) and analyzed with non-parametric tests. Results: Diode Laser activation technique resulted in the highest temperature rise on the external root surface, followed by the Ultrasonic, with no statistically significant difference observed among the remaining groups. In terms of efficacy, Ultrasonic and Sonic activation achieved significantly greater irrigant penetration in samples without BMH, and greater BMH removal in samples with BMH, compared to Diode Laser, XP-Finisher, and Control groups. Conclusions: In this in vitro study, Diode Laser caused the highest temperature rise, followed by Ultrasonic, with significant increases from 30 to 60 s. Temperature rise did not significantly affect penetration or BMH removal. Ultrasonic and Sonic irrigation techniques achieved the highest depth of penetration (without BMH) and biofilm-mimicking Hydrogel removal (with BMH) compared to Diode Laser, XP-Finisher, and Control.


25 September 2025 in Australian Endodontic Journal
Verified
Journal Article
Closed access
FDFatimah Dahlawi
Fatimah Dahlawi
MAMohammed AlGharni
Mohammed AlGharni
MMMarwa Madi
Marwa Madi
NHNeveen Mokhtar Ayad Hanna
Neveen Mokhtar Ayad Hanna
FAFaisal Alonizan
Faisal Alonizan
OOOmar Omar
Omar Omar

31 March 2025 in F1000Research
Verified
Journal Article
Open access
PDF file
NHNeveen Mokhtar Ayad Hanna
Neveen Mokhtar Ayad Hanna
Nanocellulose (NC) is one of the most prominent green materials for various applications. They have received increasing attention owing to their unique properties. In this review, a brief background on cellulose, its abundance in nature, chemical structure, and properties is described. Subsequently, the structure of nanocellulose, the procedures of its production, and its characteristics are discussed. This was followed by elaborating on the recent use of nanocellulose in medical and dental fields.