Siripatra Patchanee

Dr. Siripatra Patchanee

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CTChonakan Thitiyuk
Chonakan Thitiyuk
SPSiripatra Patchanee
Siripatra Patchanee
Awiruth KlaisiriAwiruth Klaisiri
Awiruth Klaisiri
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
This prospective cohort study aimed to assess changes in quality of life (QoL) for “orthodontic first” approach (OFA) and “surgery first” approach (SFA) patients. Sixty patients who underwent orthognathic surgery via either the OFA (n = 30) or the SFA (n = 30) provided self-administered questionnaires (SAQs) about their orthognathic quality of life (Thai version OQLQ). Data were collected at four time points: before surgery (T1), and postoperatively, at 1 (T2), 3 (T3) and 6 months (T4). Intragroup and intergroup comparisons were performed by the Friedman test and the Mann–Whitney U test, respectively. Both the OFA and the SFA showed that QoL scores gradually improved in each domain for 6 months after surgery. The pattern of improvement after surgery in the SFA group was: facial esthetics (E) at 1 month; awareness of facial deformities (A) and social aspects of deformity (S) at 3 months; oral function (F) at 6 months. The pattern of improvement after surgery in the OFA group was: facial esthetics (E) and social aspects of deformity (S) at 1 month; awareness of facial deformities (A) at 3 months; oral function (F) at 6 months. The most concerning domain for Thai patients in our center OQLQ was the facial esthetic domain.

22 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SBSukumal Boonlue
Sukumal Boonlue
SPSiripatra Patchanee
Siripatra Patchanee
SISamroeng Inglam
Samroeng Inglam
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
This study analyzed the biomechanical behavior under simulated conditions between a novel modification of the Low Z plasty (NM-Low Z) technique and the conventional Hunsuck–Epker (HE) technique on mandibular advancement surgery. The NM-Low Z technique was developed with the purpose of reducing post-operative complications by facilitating the operative method of lower jaw surgery. The models were investigated under physiological muscular and occlusal loads at 1, 2, 4, 6, and 8 weeks post-operation. Finite element analysis was used to analyze stress distribution, elastic strain, and model displacement. Maximum equivalent von Mises stresses were observed on the fixation system and bone. The elastic strain at the fracture site represented the optimal bone-healing capacity. The NM-Low Z model showed lower stress than the HE model at the 2-week post-operation stage and onwards. The elastic strains observed in both models were situated within the normal range for bone healing. The ranges of displacement for the NM-Low Z model were less than those in the HE model. Based on the data sets studied, the biomechanical study of the NM-Low Z technique can be favorably compared to the conventional HE technique. The NM-Low Z technique promotes post-operation skeletal stability by lowering stress on fixation and bone, with less displacement of the segment during bone-healing periods.

28 December 2025 in Medicina
Verified
Journal Article
Open access
PDF file
PNPassorn Nuntapolchai
Passorn Nuntapolchai
SPSiripatra Patchanee
Siripatra Patchanee
COChanekrid Oupadissakoon
Chanekrid Oupadissakoon
PCPhetcharat Chatmongkhonkit
Phetcharat Chatmongkhonkit
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
Background and Objectives: This study aimed to assess the pattern and quantity of bone regeneration after mandibular setback surgery using a novel modification of the low Z plasty (NM-Low Z plasty) technique by measuring bone density (Hounsfield unit) at the osteotomy site over a 12-month postoperative period using cone-beam computed tomography (CBCT). Materials and Methods: This retrospective cohort study included six patients with skeletal Class III deformity who underwent bilateral sagittal split osteotomy (BSSO) setback using the NM-Low Z plasty technique between 2021 and 2023 at Thammasat University Hospital. CBCT images were obtained preoperatively and at 1 month, 6 months, and 12 months postoperatively. Bone density at the buccal, cancellous, and lingual aspects of the osteotomy gap was measured using Blue Sky Plan 4 software. The intraclass correlation coefficient was used to determine reliability. Descriptive statistics, repeated-measures analysis of variance and multiple linear regression analysis were performed for comparisons. Results: At 12 months postoperatively, bone density in all measured regions was not significantly different compared to the postoperative measurements, indicating sufficient bone regeneration. The cancellous and lingual cortical regions exhibited earlier recovery than the buccal cortex. No postoperative complications such as wound infection, delayed union, or non-union were reported. Conclusions: BSSO using the NM-Low Z plasty technique offers reliable bone healing outcomes with stable bone regeneration, thereby providing a viable alternative to conventional BSSO techniques. Radiographic evidence confirmed its clinical applicability and potential to reduce the incidence of postoperative complications.

17 October 2026 in Healthcare
Verified
Journal Article
Open access
PDF file
CSChanistha Sirichan
Chanistha Sirichan
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
SPSiripatra Patchanee
Siripatra Patchanee
Background/Objectives: Sagittal skeletal patterns are associated with upper airway dimensions, which may influence breathing during sleep and potentially relate to sleep quality. We hypothesized that global Thai-Pittsburgh Sleep Quality Index (Thai-PSQI) scores would differ among skeletal Class I (Sk-I), Class II (Sk-II), and Class III (Sk-III) groups. Methods: This cross-sectional study was conducted at the Department of Orthodontics, Faculty of Dentistry, Thammasat University, from June 2023 to March 2024. Ninety-three patients aged 18–50 years presenting to initiate orthodontic treatment were classified by ANB angle as Sk-I (0.5–5.1°), Sk-II (>5.1°), or Sk-III ( 5 indicated poor sleep quality. Sex, age, and BMI were analyzed as demographic variables. Results: Mean global PSQI scores were 6.42 ± 2.71, 6.68 ± 3.39, and 6.26 ± 2.46 for Sk-I, Sk-II, and Sk-III, respectively. Global PSQI scores did not differ significantly among skeletal groups (H = 0.024, p = 0.988, ε2 < 0.001). Overall, 55.9% of participants were poor sleepers, and the distribution of good and poor sleepers did not differ among groups (χ2 = 1.134, p = 0.567, Cramer’s V = 0.110). No significant associations were observed between global PSQI and sex, age, or BMI (p = 0.279, 0.848, and 0.948, respectively). Conclusions: No statistically significant differences in subjective sleep quality were identified among the three sagittal skeletal groups in this sample.

5 March 2026 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
SPSiripatra Patchanee
Siripatra Patchanee
PAPokpong Amornvit
Pokpong Amornvit
ASAunchisa Sreatsiripakdee
Aunchisa Sreatsiripakdee
CTChantawat Tanapirom
Chantawat Tanapirom
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
Background/Objectives: Among vat polymerization technologies, liquid-crystal display (LCD) 3D printing has gained popularity in dentistry because of its affordability and acceptable resolution. However, the factors influencing the dimensional accuracy of LCD-printed surgical splints, particularly build platform position, remain insufficiently investigated. This study aimed to evaluate the influence of build platform position on the trueness and precision of orthognathic surgical splints fabricated using LCD 3D printing technology. Methods: Thirty-six surgical splints were printed from a master digital file using an LCD 3D printer. All surgical splints were printed with a 90-degree layer orientation to the building platform. The layer thickness was set at 100 μm. The surgical splints were divided into three groups according to their printing position on the building platform: middle (M), left (Lt), and right (Rt). Each 3D-printed surgical splint was sprayed with an opaque scanning spray and then rescanned to create digital files for testing. A surface-based superimposition and deviation analysis was performed using specialized 3D software to evaluate accuracy of surgical splints. Root mean square error (RMSE) values were statistically analyzed. Results: There were no statistically significant differences in trueness among the middle, left, and right printing positions on the build platform (p > 0.05). In contrast, printing position significantly affected precision, with surgical splints printed at the center of the build platform demonstrating significantly lower RMSE values compared with those printed at the left and right positions (p < 0.001). In addition, no significant difference in precision was detected between the left and right positions. Conclusions: The printing position on the build platform significantly influences the precision of orthognathic surgical splints fabricated using LCD 3D printing technology. Splints printed at the central region of the build platform exhibited the highest precision, whereas trueness was not significantly affected by printing position. These findings suggest that preferential placement of surgical splints at the center of the build platform may improve fabrication consistency and predictability in digital orthognathic surgery workflows.

19 June 2026 in Healthcare
Verified
Journal Article
Open access
PDF file
PCPhetcharat Chatmongkhonkit
Phetcharat Chatmongkhonkit
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
ASArthessarat Sirisa-Ard
Arthessarat Sirisa-Ard
SPSiripatra Patchanee
Siripatra Patchanee
Objectives: This study aimed to evaluate and compare the cost-effectiveness of the surgery-first and orthodontic-first approaches in Thai patients with dentofacial deformities undergoing orthognathic surgery. Methods: This retrospective cohort study included 30 patients with dentofacial deformities, divided into the surgery-first approach (SFA, n = 15) and orthodontic-first approach (OFA, n = 15). All underwent double-jaw surgery without genioplasty performed by a single surgeon and orthodontist. Data collected included operative and orthodontic costs, operative time, total treatment and hospital costs, treatment duration, and length of hospital stay. Cost-effectiveness was assessed using the incremental cost-effectiveness ratio (ICER) and incremental time-effectiveness ratio (ITER), with effectiveness measured by quality of life via the Thai Orthognathic Quality of Life Questionnaire (OQLQ) before and at the time of debonding the orthodontic appliance. Results: Overall, the SFA demonstrated greater cost-effectiveness than the OFA. However, the SFA group incurred slightly higher hospital costs. There were no statistically significant differences between the two groups in operative cost, hospital cost, total cost, operative time, or length of hospital stay (p > 0.05). By contrast, orthodontic cost, orthodontic treatment duration, and total treatment duration were significantly lower in the SFA group compared with the OFA group (p < 0.05). Conclusions: Within limits, the SFA is a potentially beneficial alternative to OFA. Patients and clinicians may benefit from using SFA by experiencing shorter treatment duration, lower orthodontic treatment costs, and improvements in certain aspects of quality of life. Further studies with larger sample sizes and longitudinal data are necessary to establish the long-term effectiveness.