Narissaporn Chaiprakit

Dr. Narissaporn Chaiprakit

Oral and Maxillofacial Surgery, Faculty of Dentistry, Thammasat University, Khlong Luang, Pathum Thani, Thailand
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CTChonakan Thitiyuk
Chonakan Thitiyuk
SPSiripatra Patchanee
Siripatra Patchanee
Awiruth KlaisiriAwiruth Klaisiri
Awiruth Klaisiri
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
This prospective cohort study aimed to assess changes in quality of life (QoL) for “orthodontic first” approach (OFA) and “surgery first” approach (SFA) patients. Sixty patients who underwent orthognathic surgery via either the OFA (n = 30) or the SFA (n = 30) provided self-administered questionnaires (SAQs) about their orthognathic quality of life (Thai version OQLQ). Data were collected at four time points: before surgery (T1), and postoperatively, at 1 (T2), 3 (T3) and 6 months (T4). Intragroup and intergroup comparisons were performed by the Friedman test and the Mann–Whitney U test, respectively. Both the OFA and the SFA showed that QoL scores gradually improved in each domain for 6 months after surgery. The pattern of improvement after surgery in the SFA group was: facial esthetics (E) at 1 month; awareness of facial deformities (A) and social aspects of deformity (S) at 3 months; oral function (F) at 6 months. The pattern of improvement after surgery in the OFA group was: facial esthetics (E) and social aspects of deformity (S) at 1 month; awareness of facial deformities (A) at 3 months; oral function (F) at 6 months. The most concerning domain for Thai patients in our center OQLQ was the facial esthetic domain.

23 February 2022 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
ODOrawee Dumrongwanich
Orawee Dumrongwanich
NCNattapon Chantarapanich
Nattapon Chantarapanich
SPSiripatra Patchanee
Siripatra Patchanee
SISamroeng Inglam
Samroeng Inglam
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
A novel modification of the Low Z plasty (NM-Low Z) technique for bilateral sagittal split osteotomy was recently proposed. The osteotomy line was modified more inferiorly than in the conventional Hunsuck–Epker (HE) approach. The NM-Low Z technique enhances the mandibular setback distance and degree of rotation in severe skeletal discrepancies. This study aimed to investigate the biomechanical behavior under simulated forces, and to compare the NM-Low Z and HE techniques on the mandible with Class III skeletal deformity at 1 week, 3 weeks, and 6 weeks post-operation. Physiological muscular and occlusal loads were simulated using the finite element (FE) method. Stresses on the miniplate, screws, and bone were observed and compared between the two models. The elastic strain at the fracture site was observed for the optimal bone-healing capacity. The NM-Low Z model exhibited a lower stress than the HE model at every stage post-operation. Both models demonstrated elastic strains within the normal range for bone healing. In summary, the biomechanical behavior of the NM-Low Z technique is comparable to that of the conventional EH technique. NM-Low Z could facilitate post-operation skeletal stability by reducing the stress on fixation materials during bone healing.

12 December 2024 in Heliyon
Verified
Journal Article
Open access
SPSiripatra Patchanee
Siripatra Patchanee
PAPokpong Amornvit
Pokpong Amornvit
MMManeethip Mortin
Maneethip Mortin
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
To evaluate the accuracy (trueness and precision) of liquid crystal display (LCD)-printed orthognathic surgical splints under two different post-processing conditions—rinsing solvent and post-polymerization time. An LCD 3D printer was used to create 48 surgical splints using the same reference standard tessellation language (STL) files. They were randomly assigned to two experimental studies. In the rinsing solvent study, 24 surgical splints were divided into three groups (n = 8) based on their rinsing solvents: isopropyl alcohol (IPA), ethanol, and water. In the post-polymerization time study, 24 surgical splints were divided into three groups (n = 8) based on the post-polymerization time: (3, 6, and 10 min). The surgical splints were covered with an opaque scanning spray, scanned, and converted into STL files. The images were trimmed and superimposed onto the reference STL file to evaluate trueness and precision, and the deviation was calculated using the root mean square (RMS) formula. Color map data were also obtained. The RMS was statistically analyzed using one-way analysis of variance and Tukey's test (α < 0.05). The lowest RMS values of trueness and precision were observed in the IPA group and the 6-min post-polymerization time groups (p < 0.05). The IPA-rinse and 6-min polymerization groups (p < 0.05) demonstrated the highest accuracy for LCD-printed orthognathic surgical splint fabrication. The dimensional accuracy of LCD-printed surgical splints is affected by the post-processing conditions, including the rinsing solvent and polymerization time. The RMS and color map data associated with the IPA-rinse and 6-min polymerization corresponded to the highest accuracy.

22 February 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SBSukumal Boonlue
Sukumal Boonlue
SPSiripatra Patchanee
Siripatra Patchanee
SISamroeng Inglam
Samroeng Inglam
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
This study analyzed the biomechanical behavior under simulated conditions between a novel modification of the Low Z plasty (NM-Low Z) technique and the conventional Hunsuck–Epker (HE) technique on mandibular advancement surgery. The NM-Low Z technique was developed with the purpose of reducing post-operative complications by facilitating the operative method of lower jaw surgery. The models were investigated under physiological muscular and occlusal loads at 1, 2, 4, 6, and 8 weeks post-operation. Finite element analysis was used to analyze stress distribution, elastic strain, and model displacement. Maximum equivalent von Mises stresses were observed on the fixation system and bone. The elastic strain at the fracture site represented the optimal bone-healing capacity. The NM-Low Z model showed lower stress than the HE model at the 2-week post-operation stage and onwards. The elastic strains observed in both models were situated within the normal range for bone healing. The ranges of displacement for the NM-Low Z model were less than those in the HE model. Based on the data sets studied, the biomechanical study of the NM-Low Z technique can be favorably compared to the conventional HE technique. The NM-Low Z technique promotes post-operation skeletal stability by lowering stress on fixation and bone, with less displacement of the segment during bone-healing periods.

4 July 2022 in European Journal of Dentistry
Verified
Journal Article
Open access
PDF file
SISarunpong Imampai
Sarunpong Imampai
SPSiripatra Patchanee
Siripatra Patchanee
Awiruth KlaisiriAwiruth Klaisiri
Awiruth Klaisiri
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
Objective The study's objective was to evaluate skeletal changes in 38 skeletal class III patients following mandibular setback surgery using NM-Low Z plasty. Materials and Methods Thirty-eight skeletal class III patients (ANB angle lower than 0) who underwent the NM-Low Z plasty technique for surgical mandibular setback procedure at Thammasat University Hospital between January 2017 and March 2020 were included in the study: 29 patients had two jaw surgeries, and 9 patients had one jaw surgery. An additional 14 patients had genioplasty. Three lateral cephalograms were traced and digitized with Dolphin Imaging software: T0, T1, and T2. The distance between the B-point and the SN7 perpendicular line defined immediate changes after surgery (T1-T0) and stability after surgery (T2-T1). The reliability test included 6 cephalograms retraced after 2-week interval. At point B, the principal result was horizontal movement forward. Statistical Analysis The analysis used paired t-tests. Results The mean mandibular setback was 9.78 mm, and the mean skeletal relapse was 2.61 mm, or 26.69%. Statistical analysis showed postoperative differences (p < 0.05). Vertical measurement in B-SN7 reduced immediately and postoperatively. Conclusion Postoperatively, the mandible relapsed significantly forward and upward. Rotational relapse is a concern with NM-Low Z plasty in hypo-/normodivergent patients.

28 December 2025 in Medicina
Verified
Journal Article
Open access
PDF file
PNPassorn Nuntapolchai
Passorn Nuntapolchai
SPSiripatra Patchanee
Siripatra Patchanee
COChanekrid Oupadissakoon
Chanekrid Oupadissakoon
PCPhetcharat Chatmongkhonkit
Phetcharat Chatmongkhonkit
Narissaporn ChaiprakitNarissaporn Chaiprakit
Narissaporn Chaiprakit
Background and Objectives: This study aimed to assess the pattern and quantity of bone regeneration after mandibular setback surgery using a novel modification of the low Z plasty (NM-Low Z plasty) technique by measuring bone density (Hounsfield unit) at the osteotomy site over a 12-month postoperative period using cone-beam computed tomography (CBCT). Materials and Methods: This retrospective cohort study included six patients with skeletal Class III deformity who underwent bilateral sagittal split osteotomy (BSSO) setback using the NM-Low Z plasty technique between 2021 and 2023 at Thammasat University Hospital. CBCT images were obtained preoperatively and at 1 month, 6 months, and 12 months postoperatively. Bone density at the buccal, cancellous, and lingual aspects of the osteotomy gap was measured using Blue Sky Plan 4 software. The intraclass correlation coefficient was used to determine reliability. Descriptive statistics, repeated-measures analysis of variance and multiple linear regression analysis were performed for comparisons. Results: At 12 months postoperatively, bone density in all measured regions was not significantly different compared to the postoperative measurements, indicating sufficient bone regeneration. The cancellous and lingual cortical regions exhibited earlier recovery than the buccal cortex. No postoperative complications such as wound infection, delayed union, or non-union were reported. Conclusions: BSSO using the NM-Low Z plasty technique offers reliable bone healing outcomes with stable bone regeneration, thereby providing a viable alternative to conventional BSSO techniques. Radiographic evidence confirmed its clinical applicability and potential to reduce the incidence of postoperative complications.