George Dabanlis

Mr. George Dabanlis

Environmental Engineering, Democritus University of Thrace, Xánthi, Anatolikí Makedonía kai Thráki, Greece
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GDGeorge Dabanlis
George Dabanlis
LGLoupa Glykeria
Loupa Glykeria
Georgios Archimidis TsalidisGeorgios Archimidis Tsalidis
Georgios Archimidis Tsalidis
EKEvangelia Kostenidou
Evangelia Kostenidou
SPYRIDON RAPSOMANIKISSPYRIDON RAPSOMANIKIS
SPYRIDON RAPSOMANIKIS
Energy efficiency in museums and buildings that house works of art or cultural heritage appears to be a difficult achievement if indoor air quality has to be kept at appropriate levels for artefacts’ long-term sustainability. There is a gap in our scientific literature on the relationship between indoor air quality and energy efficiency, meaning that there are no numerical data that examine both of them simultaneously, although this is a theme that is broadly discussed by museum managers, curators, and scientists. It is certain that the two parameters, indoor air quality (IAQ) and energy efficiency (EEF) are conflicting and difficult to reconcile. Furthermore, IAQ is not only the determination of temperature, relative humidity, and CO2, as is usually presented. Using green or renewable energy does not make a building “energy efficient”. Hence, in the manuscript we review the literature on IAQ of museums and exhibition buildings, in conjunction with the consideration of their EEF. Hopefully, reviewing the literature for this problem may lead to carefully designed monitoring experiments. The selection, application, and testing of appropriate technological measures can lead to a new balance between the two conflicting parameters. Not only must solutions be found, but these solutions are necessary in the mitigation battle against climate change.

1 February 2025 in Air
Verified
Journal Article
Open access
PDF file
LGLoupa Glykeria
Loupa Glykeria
GDGeorge Dabanlis
George Dabanlis
EKEvangelia Kostenidou
Evangelia Kostenidou
SPYRIDON RAPSOMANIKISSPYRIDON RAPSOMANIKIS
SPYRIDON RAPSOMANIKIS
Museums play a vital role in preserving cultural heritage and for this reason, they require strict indoor environmental controls. Balancing indoor environmental quality with reduced energy consumption poses significant challenges. Over the course of a year (2023), indoor microclimate conditions, atmospheric pollutant concentrations (O3, TVOC, CO, CO2, particulate matter), and energy use were monitored at the Archaeological Museum of Kavala. Maximum daily fluctuations in relative humidity were 15% in summertime, while air temperature variations reached 2.0 °C, highlighting unstable microclimatic conditions. Particulate matter was the primary threat to the preservation of artworks, followed by indoor O3 and NO2, whose concentrations exceeded recommended limits for cultural conservation. In 2023, the Energy Use Intensity (EUI) was 86.1 kWh m−2, a value that is significantly correlated with the number of visitors and the outdoor air temperature. Every person visiting the museum was assigned an average of 7.7 kWh of energy. During the hottest days and when the museum was crowded, the maximum amount of energy was consumed. Over the past decade (2013–2023), the lowest EUI was recorded during the COVID-19 pandemic at 53 kWh m−2. Energy consumption is linked to indoor environmental quality; thus, both must be continuously monitored.

22 November 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
GDGeorge Dabanlis
George Dabanlis
LGLoupa Glykeria
Loupa Glykeria
DLDimitrios Liakos
Dimitrios Liakos
SPYRIDON RAPSOMANIKISSPYRIDON RAPSOMANIKIS
SPYRIDON RAPSOMANIKIS
Indoor air pollutant sources are crucial in assessing IAQ, especially when outdoor air pollutant concentrations are low. In the present study, PM mass concentrations in a range of five sizes; CO, CO2, O3, NO, NO2, and TVOC concentrations; along with temperature and relative humidity were monitored in three indoor locations of a university. The monitoring took place in a building dedicated to teaching undergraduates. The first two locations, a professor’s office and a computer centre (laboratory), were not refurbished. The classroom under study is refurbished and now is airtight, as are all of the classrooms in this building. Air purifiers were installed in all of the classrooms to prevent the transmission of infectious pollutants. In all monitored locations, people were the main indoor source of PM, CO2, and TVOC. The operation of twelve computers in the small laboratory did not contribute to the air pollution, at least for the examined pollutants. The air purifier decreased the PM concentrations, but not the gaseous air pollutants.

30 April 2024 in Aerobiology
Verified
Journal Article
Open access
PDF file
LGLoupa Glykeria
Loupa Glykeria
GDGeorge Dabanlis
George Dabanlis
GRGeorgia Resta
Georgia Resta
EKEvangelia Kostenidou
Evangelia Kostenidou
SPYRIDON RAPSOMANIKISSPYRIDON RAPSOMANIKIS
SPYRIDON RAPSOMANIKIS
Indoor microclimate conditions and air pollutant concentrations (O3, TVOC, CO, CO2, and particulate matter mass concentrations in six size bins) were measured in the Greek Archaeological Museum of Abdera, which houses priceless works of art from the birthplace of the ancient philosopher Democritus. The monitoring campaign took place during the spring and summer months, when there were the greatest number of visitors. In the exhibition rooms, daily variations in relative humidity ranged from 4% to 10%, and daily variations in air temperature ranged from 0.9 °C to 2.6 °C. These uncontrolled changes may endanger the housed antiquities. The microclimate in the storage rooms varied substantially less than in the exhibition halls due to dehumidifiers and the lack of visitors. Concerning air pollution, indoor O3 concentrations were higher than the recommended limit values for the conservation of artwork. Even more worrisome are particulate matter mass concentrations above the air quality guidelines. Despite the fact that the building is well insulated and that only artificial lighting is used in the exhibition halls, it is difficult to achieve adequate conditions for the protection of the works of art.