13 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Hassan MehboobHassan Mehboob
Hassan Mehboob
AOAbdelhak Ouldyerou
Abdelhak Ouldyerou
MIMuhammad Farzik Ijaz
Muhammad Farzik Ijaz
The design of the implant and osseointegration play an important role in the long-term stability of implants. This study aims to investigate the impact of porous implants on full and partial osseointegration in varying bone qualities. Finite element models of porous implants were modeled and assembled with normal and weak bones considering full and partial osseointegration. These assemblies were simulated under an occlusal load of 200 N when the outer surfaces of bones were fixed in all directions. The results showed that in the case of full osseointegration, the stresses in surrounding bones were increased with decreasing implant stiffness, while decreased in partial osseointegration. Moreover, the maximum octahedral shear strain in the weak bone exceeded 3000 µε in all the cases but decreased (from 7256 to 3632 µε) with decreasing implant stiffness. According to the mechanostat hypothesis, using porous implants in normal bone may enhance bone density in full osseointegration, while susceptivity of bone damage may reduce in weak bones using porous implants. Thus, careful selection of implant material and design based on the patient’s specific bone quality is crucial for successful outcomes.

9 December 2022 in Materials
Verified
Journal Article
Open access
PDF file
El-Sayed M. SherifEl-Sayed M. Sherif
El-Sayed M. Sherif
YBYassir Ahmed Bahri
Yassir Ahmed Bahri
HAHamad Alharbi
Hamad Alharbi
MIMuhammad Farzik Ijaz
Muhammad Farzik Ijaz
IAIbrahim A. Alnaser
Ibrahim A. Alnaser
Ti-15%Zr alloy and Ti-15%Zr-2%Ta alloy were fabricated to be used in biomedical applications. The corrosion of these two alloys after being immersed in simulated body fluid for 1 h and 72 h was investigated. Different electrochemical methods, including polarization, impedance, and chronoamperometric current with time at 400 mV were employed. Also, the surface morphology and the compositions of its formed film were reported by the use of scanning electron microscope and energy dispersive X-ray. Based on the collected results, the presence of 2%Ta in the Ti-Zr alloy passivated its corrosion by minimizing its corrosion rate. The polarization curves revealed that adding Ta within the alloy increases the corrosion resistance as was confirmed by the impedance spectroscopy and current time data. The change of current versus time proved that the addition of Ta reduces the absolute current even at high anodic potential, 400 mV. The results of both electrochemical and spectroscopic methods indicated that pitting corrosion does not occur for both Ti-Zr and Ti-Zr-Ta alloys, even after their immersion in SBF solutions for 72 h.

4 October 2016 in Materials
Verified
Journal Article
Open access
PDF file
RIRaluca Ion
Raluca Ion
SDSilviu Iulian Drob
Silviu Iulian Drob
MIMuhammad Farzik Ijaz
Muhammad Farzik Ijaz
CVCora Vasilescu
Cora Vasilescu
POPetre Osiceanu
Petre Osiceanu
TGThierry Gloriant
Thierry Gloriant
A new superelastic Ti‐23Hf‐3Mo‐4Sn biomedical alloy displaying a particularly large recovery strain was synthesized and characterized in this study. Its native passive film is very thick (18 nm) and contains very protective TiO2, Ti2O3, HfO2, MoO2, and SnO2 oxides (XPS analysis). This alloy revealed nobler electrochemical behavior, more favorable values of the corrosion parameters and open circuit potentials in simulated body fluid in comparison with commercially pure titanium (CP‐Ti) and Ti‐6Al‐4V alloy taken as reference biomaterials in this study. This is due to the favorable influence of the alloying elements Hf, Sn, Mo, which enhance the protective properties of the native passive film on alloy surface. Impedance spectra showed a passive film with two layers, an inner, capacitive, barrier, dense layer and an outer, less insulating, porous layer that confer both high corrosion resistance and bioactivity to the alloy. In vitro tests were carried out in order to evaluate the response of Human Umbilical Vein Endothelial Cells (HUVECs) to Ti‐23Hf‐3Mo‐4Sn alloy in terms of cell viability, cell proliferation, phenotypic marker expression and nitric oxide release. The results indicate a similar level of cytocompatibility with HUVEC cells cultured on Ti‐23Hf‐3Mo‐4Sn substrate and those cultured on the conventional CP‐Ti and Ti‐6Al‐4V metallic materials.

10 March 2020 in Crystals
Verified
Journal Article
Open access
PDF file
MMMonis Luqman Mohammed
Monis Luqman Mohammed
ASAsiful Seikh
Asiful Seikh
ASAmit Sarkar
Amit Sarkar
SRSameh Abdallah Ragab
Sameh Abdallah Ragab
JMJabair Mohammed
Jabair Mohammed
Hany S. AbdoHany S. Abdo
Hany S. Abdo
Owing to their superior biocompatibility, titanium and its alloys are often the first choice for implant materials in biomedical applications, especially for dental and bone repairs (orthodontics and prosthodontics). Titanium has low density and shows good mechanical and chemical properties. Although Ti-6Al-4V alloy exhibits excellent corrosion resistance properties, the metal ions released during corrosion are likely to induce aseptic loosening in long-term implantations. In the present study, Ti-6Al-4V alloy was subjected to two specific heat treatments, namely, air cooling and water quenching. The potentiodynamic polarization and electrochemical impedance spectroscopy measurements revealed remarkable improvement in the corrosion resistance properties of the heat-treated specimens. The presence of the β phase is a plausible reason for the improvement. Scanning electron microscopy, X-ray diffraction phase composition analysis, and microstructural characterization were performed to confirm the presence of the β phase.

1 December 2022 in Materials
Verified
Journal Article
Open access
PDF file
MIMuhammad Farzik Ijaz
Muhammad Farzik Ijaz
HAHamad Alharbi
Hamad Alharbi
YBYassir Ahmed Bahri
Yassir Ahmed Bahri
El-Sayed M. SherifEl-Sayed M. Sherif
El-Sayed M. Sherif
Very often, pure Ti and (α + β) Ti-6Al-4V alloys have been used commercially for implant applications, but ensuring their chemical, mechanical, and biological biocompatibility is always a serious concern for sustaining the long-term efficacy of implants. Therefore, there has always been a great quest to explore new biomedical alloying systems that can offer substantial beneficial effects in tailoring a balance between the mechanical properties and biocompatibility of implantable medical devices. With a view to the mechanical performance, this study focused on designing a Ti-15Zr-2Ta-xSn (where x = 4, 6, 8) alloying system with high strength and low Young’s modulus prepared by a powder metallurgy method. The experimental results showed that mechanical alloying, followed by spark plasma sintering, produced a fully consolidated (α + β) Ti-Zr-Ta-Sn-based alloy with a fine grain size and a relative density greater than 99%. Nevertheless, the shape, size, and distribution of α-phase precipitations were found to be sensitive to Sn contents. The addition of Sn also increased the α/β transus temperature of the alloy. For example, as the Sn content was increased from 4 wt.% to 8 wt.%, the β grains transformed into diverse morphological characteristics, namely, a thin-grain-boundary α phase (αGB), lamellar α colonies, and acicular αs precipitates and very low residual porosity during subsequent cooling after the spark plasma sintering procedure, which is consistent with the relative density results. Among the prepared alloys, Ti-15Zr-2Ta-8Sn exhibited the highest hardness (s340 HV), compressive yield strength (~1056 MPa), and maximum compressive strength (~1470). The formation of intriguing precipitate–matrix interfaces (α/β) acting as dislocation barriers is proposed to be the main reason for the high strength of the Ti-15Zr-2Ta-8Sn alloy. Finally, based on mechanical and structural properties, it is envisaged that our developed alloys will be promising for indwelling implant applications.

2 October 2020 in Crystals
Verified
Journal Article
Open access
PDF file
Talal AlShammariTalal AlShammari
Talal AlShammari
HAHamad Alharbi
Hamad Alharbi
MSMahmoud S. Soliman
Mahmoud S. Soliman
MIMuhammad Farzik Ijaz
Muhammad Farzik Ijaz
The aim of the present research is to manipulate the amenability between composition-microstructure-property relationships in two kinds of Al-4Cu-xMg-0.3Ag alloys (where x = 0.4 and 1.4) having different Cu/Mg ratios (~9.54 and ~2.87). The effect of artificial ageing (T6) on the precipitation hardening behavior and resulting mechanical properties were also assessed and compared to two different scenarios of composition. Experimental results revealed that the modification in Magnesium concentration from 0.4 to 1.4 wt.% has a marked effect in increasing the micro hardness, ultimate tensile stress, and elongation of the alloy. Based on the microstructural analysis, the enhancement in mechanical properties was explained and addressed by considering the dual role of Mg content in the base alloy. On one hand, a large size of Mg atom produces a solid solution hardening effect, while on the other hand, a high content of Mg further promotes the formation of second phase S-type precipitate (Al2CuMg) with various mixed morphologies. This unraveling co-precipitation phases within the matrix provide an obstacle for the dislocation glide thereby increasing mechanical strength and strain hardenability.