Na Hye Kwon

Ms. Na Hye Kwon

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
NKNa Hye Kwon
Na Hye Kwon
DSDong Oh Shin
Dong Oh Shin
JKJinsung Kim
Jinsung Kim
JYJaeryong Yoo
Jaeryong Yoo
MPMin Seok Park
Min Seok Park
SCSang Hyoun Choi
Sang Hyoun Choi

31 December 2020 in Progress in Medical Physics
Verified
Journal Article
Open access
PDF file
NKNa Hye Kwon
Na Hye Kwon
YJYoung jae Jang
Young jae Jang
DKDong Wook Kim
Dong Wook Kim
DSDong Oh Shin
Dong Oh Shin
KKKum Bae Kim
Kum Bae Kim
SCSang Hyoun Choi
Sang Hyoun Choi
Na Hye Kwon, Young Jae Jang, Dong Wook Kim, Dong Oh Shin, Kum Bae Kim, Jin Sung Kim, Sang Hyoun Choi. Progress in Medical Physics 2020;31:194-204. https://doi.org/10.14316/pmp.2020.31.4.194

20 September 2022 in Journal of the Korean Physical Society
Verified
Journal Article
Closed access
PDF file
YJYoung jae Jang
Young jae Jang
NKNa Hye Kwon
Na Hye Kwon
SPSeong Hee Park
Seong Hee Park
YCYona Choi
Yona Choi
HYHyungjoon Yu
Hyungjoon Yu
SCSang Hyoun Choi
Sang Hyoun Choi

23 February 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
YJYoung jae Jang
Young jae Jang
NKNa Hye Kwon
Na Hye Kwon
SPSeong Hee Park
Seong Hee Park
YCYona Choi
Yona Choi
KKKum Bae Kim
Kum Bae Kim
SCSang Hyoun Choi
Sang Hyoun Choi
In Korea, when replacing or discarding parts of a medical linear accelerator (linac), self-disposal is required in the consideration of the activity, but there is no standard regulation to manage radioactive waste. The aim of this study is to check the activity of each part to determine the disposal time according to the clearance level for self-disposal. The results of measuring the components of the linac head parts of the disposed Varian, Elekta, and Siemens equipment were reflected in the Monte Carlo simulation to confirm the radionuclide change according to the presence or absence of impurities. To confirm the degree of activation of the linac, the main radionuclides according to the time after the linac shutdown, considering the workloads of 40/80 Gy/day of 10/15 MV linac irradiated with beams for 10 years in the results of the simulation of the linac parts, and the radionuclide concentration was confirmed. As a result of applying the clearance level for self-disposal in the notice of the Korean Nuclear Safety (KINS) to each linac head part, most parts of the 10 MV linac could be dismantled after 1 month, and 15 MV target and primary collimators were stored after a long period of time before being dismantled. Although additional radionuclides were identified according to the presence or absence of impurities, the disposal timing for each part did not change significantly. In this study, the clearance level for self-disposal for each radionuclide was applied to activated parts by three manufacturers to confirm the self-disposal timing and predict the timing at which workers are not exposed to radiation during dismantling/disposal.

1 February 2022 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
NKNa Hye Kwon
Na Hye Kwon
DSDong Oh Shin
Dong Oh Shin
SASo Hyun Ann
So Hyun Ann
JKJin Sung Kim
Jin Sung Kim
SCSang Hyoun Choi
Sang Hyoun Choi
DKDong Wook Kim
Dong Wook Kim

22 July 2022 in Radiation Physics and Chemistry
Verified
Journal Article
Closed access
DCDong Hyeok Choi
Dong Hyeok Choi
DKDong Wook Kim
Dong Wook Kim
SASo Hyun Ahn
So Hyun Ahn
SCSang Hyoun Choi
Sang Hyoun Choi
YJYoung jae Jang
Young jae Jang
JKJin Sung Kim
Jin Sung Kim