Jing Dong

Dr. Jing Dong

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2022 in Molecules
Verified
Journal Article
Open access
PDF file
JDJing Dong
Jing Dong
JTJunwu Tang
Junwu Tang
GWGuojun Wu
Guojun Wu
RLRuizhuo Li
Ruizhuo Li
To solve the problem that turbidity in water has a significant effect on the spectra of nitrate and reduces the accuracy of nitrate detection, a turbidity-compensation method for nitrate measurement based on ultraviolet difference spectra is proposed. The effect of turbidity on the absorption spectra of nitrate was studied by using the difference spectra of the mixed solution and a nitrate solution. The results showed that the same turbidity had different effects on the absorbance of different concentrations of nitrate. The change in absorbance due to turbidity decreased with an increase in the nitrate concentration at wavelengths from 200 nm to 230 nm, although this change was constant when the wavelength was greater than 230 nm. On the basis of this characteristic, we combined the residual sum of squares (RSS) and interval partial least squares (iPLS) to select wavelengths of 230–240 nm as the optimal modeling interval. Furthermore, the turbidity-compensation model was established by the linear fitting of the difference spectra of various levels of turbidity. The absorption spectra of the nitrate were extracted by subtracting the turbidity-compensation curve from the original spectra of the water samples, and the nitrate concentration was calculated by using a partial least squares (PLS)-based nitrate-prediction model. The experimental results showed that the average relative error of the nitrate predictions was reduced by 50.33% to 1.33% by the proposed turbidity-compensation method. This indicated that this method can better correct the deviation in nitrate’s absorbance caused by turbidity and improve the accuracy of nitrate predictions.

7 February 2024 in RSC Advances
Verified
Journal Article
Open access
PDF file
JDJing Dong
Jing Dong
JTJunwu Tang
Junwu Tang
GWGuojun Wu
Guojun Wu
YXYu Xin
Yu Xin
RLRuizhuo Li
Ruizhuo Li
YLYahui Li
Yahui Li
Nitrate contamination in water sources poses a substantial environmental and health risk. However, accurate detection of nitrate in water, particularly in the presence of dissolved organic carbon (DOC) interference, remains a significant analytical challenge. This study investigates a novel approach for the reliable detection of nitrate in water samples with varying levels of DOC interference based on the equivalent concentration offset method. The characteristic wavelengths of DOC were determined based on the first-order derivatives, and a nitrate concentration prediction model based on partial least squares (PLS) was established using the absorption spectra of nitrate solutions. Subsequently, the absorption spectra of the nitrate solutions were subtracted from that of the nitrate-DOC mixed solutions to obtain the difference spectra. These difference spectra were introduced into the nitrate prediction model to calculate the equivalent concentration offset values caused by DOC. Finally, a DOC interference correction model was established based on a binary linear regression between the absorbances at the DOC characteristic wavelengths and the DOC-induced equivalent concentration offset values of nitrate. Additionally, a modeling wavelength selection algorithm based on a sliding window was proposed to ensure the accuracy of the nitrate concentration prediction model and the equivalent concentration offset model. The experimental results demonstrated that by correcting the DOC-induced offsets, the relative error of nitrate prediction was reduced from 94.44% to 3.36%, and the root mean square error of prediction was reduced from 1.6108 mg L−1 to 0.1037 mg L−1, which is a significant correction effect. The proposed method applied to predict nitrate concentrations in samples from two different water sources shows a certain degree of comparability with the standard method. It proves that this method can effectively correct the deviations in nitrate measurements caused by DOC and improve the accuracy of nitrate measurement.

23 September 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ZZZhanfei Zhang
Zhanfei Zhang
JDJing Dong
Jing Dong
YLYahui Li
Yahui Li
YWYafeng Wu
Yafeng Wu
GWGuojun Wu
Guojun Wu
In situ measurement of deep-sea nitrate concentration is of significant importance for marine environmental monitoring and management. Nitrate sensors based on ultraviolet (UV) spectrophotometry, featuring simple, rapid, and reagent-free detection, are highly suitable for long-term autonomous monitoring and have attracted increasing research interest. However, existing systems still suffer from increased measurement errors and reduced detection ranges due to light source attenuation and optical transmission losses. To address these limitations, this study presents an optical system for a deep-sea nitrate sensor designed for deployment on mobile platforms. A co-aperture coupling design integrating the measurement and reference paths is proposed to achieve low optical loss while accurately compensating for the impact of light source attenuation on measurement accuracy. Furthermore, full-UV optical component optimization is performed to significantly improve optical energy utilization. Light-source calibration experiments demonstrate stable absorbance responses and effectively compensate for measurement deviations caused by light source attenuation. Performance evaluation of the system demonstrated a detection limit of 0.0056 mg/L-N(0.4 µmol/L, 10 mm optical path), with high measurement accuracy and precision across samples with varying nitrate concentrations. Sea trial results confirmed that the proposed system satisfies the requirements for stability and reliability in deep-sea in situ nitrate concentration monitoring, highlighting its potential for practical marine applications.