Study Objectives: To clarify the effects of sleep duration on stroke and stroke subtypes, we adopted a Mendelian randomization (MR) approach to evaluate their causal relationship. Methods: A genome-wide association study including 446,118 participants from UK biobank was used to identify instruments for short sleep, long sleep and sleep duration. Summary-level data for all stroke, ischemic stroke, intracerebral hemorrhage, and their subtypes were obtained from meta-analyses conducted by the MEGASTROKE consortium. MR analyses were performed using the inverse-variance-weighted method, weighted median estimator, MR pleiotropy residual sum and outlier (MR-PRESSO) test, and MR-Egger regression. Sensitivity analyses were further performed using leave-one-out analysis, MR-PRESSO global test and Cochran's Q test to verify the robustness of our findings. Results: By two-sample MR, we didn't find causal associations between sleep duration and risk of stroke. However, in the subgroup analysis, we found weak evidence for short sleep in increasing risk of cardio-embolic stroke (odds ratio [OR], 1.33; 95% confidence interval [CI], 1.11–1.60; P = 0.02) and long sleep in increasing risk of large artery stroke [OR, 1.41; 95% CI, 1.02–1.95; P = 0.04]. But the associations were not significant after Bonferroni correction for multiple comparisons. Conclusions: Our study suggests that sleep duration is not causally associated with risk of stroke and its subtypes.
To solve the problem that turbidity in water has a significant effect on the spectra of nitrate and reduces the accuracy of nitrate detection, a turbidity-compensation method for nitrate measurement based on ultraviolet difference spectra is proposed. The effect of turbidity on the absorption spectra of nitrate was studied by using the difference spectra of the mixed solution and a nitrate solution. The results showed that the same turbidity had different effects on the absorbance of different concentrations of nitrate. The change in absorbance due to turbidity decreased with an increase in the nitrate concentration at wavelengths from 200 nm to 230 nm, although this change was constant when the wavelength was greater than 230 nm. On the basis of this characteristic, we combined the residual sum of squares (RSS) and interval partial least squares (iPLS) to select wavelengths of 230–240 nm as the optimal modeling interval. Furthermore, the turbidity-compensation model was established by the linear fitting of the difference spectra of various levels of turbidity. The absorption spectra of the nitrate were extracted by subtracting the turbidity-compensation curve from the original spectra of the water samples, and the nitrate concentration was calculated by using a partial least squares (PLS)-based nitrate-prediction model. The experimental results showed that the average relative error of the nitrate predictions was reduced by 50.33% to 1.33% by the proposed turbidity-compensation method. This indicated that this method can better correct the deviation in nitrate’s absorbance caused by turbidity and improve the accuracy of nitrate predictions.
Nitrate contamination in water sources poses a substantial environmental and health risk. However, accurate detection of nitrate in water, particularly in the presence of dissolved organic carbon (DOC) interference, remains a significant analytical challenge. This study investigates a novel approach for the reliable detection of nitrate in water samples with varying levels of DOC interference based on the equivalent concentration offset method. The characteristic wavelengths of DOC were determined based on the first-order derivatives, and a nitrate concentration prediction model based on partial least squares (PLS) was established using the absorption spectra of nitrate solutions. Subsequently, the absorption spectra of the nitrate solutions were subtracted from that of the nitrate-DOC mixed solutions to obtain the difference spectra. These difference spectra were introduced into the nitrate prediction model to calculate the equivalent concentration offset values caused by DOC. Finally, a DOC interference correction model was established based on a binary linear regression between the absorbances at the DOC characteristic wavelengths and the DOC-induced equivalent concentration offset values of nitrate. Additionally, a modeling wavelength selection algorithm based on a sliding window was proposed to ensure the accuracy of the nitrate concentration prediction model and the equivalent concentration offset model. The experimental results demonstrated that by correcting the DOC-induced offsets, the relative error of nitrate prediction was reduced from 94.44% to 3.36%, and the root mean square error of prediction was reduced from 1.6108 mg L−1 to 0.1037 mg L−1, which is a significant correction effect. The proposed method applied to predict nitrate concentrations in samples from two different water sources shows a certain degree of comparability with the standard method. It proves that this method can effectively correct the deviations in nitrate measurements caused by DOC and improve the accuracy of nitrate measurement.
Fluorescence technology is an effective tool for detecting polycyclic aromatic hydrocarbons (PAHs) in water. However, the accuracy of fluorescence detection is reduced by the spectral overlap of different PAHs and coexisting colored dissolved organic matter (CDOM). In this study, a single‐excitation interval selection method based on an excitation‐emission matrix is proposed to quantify four PAHs: fluorene, pyrene, phenanthrene, and benzo(a)pyrene under CDOM interference. The optimal excitation wavelength for each PAH was obtained by stability analysis, based on which the optimal emission interval was obtained by chaotic particle swarm optimization. The partial least squares (PLS) prediction models of four PAHs under interference were established. On comparing with other modeling methods, the results show that the models with interval selection have better prediction accuracy (mean relative error < 10%) under CDOM interference. The recovery rate and limit of detection of the method were also evaluated. This study provides a new and helpful strategy for fluorescence detection of interfering PAHs in water.
Impulsive acoustic interference can distort covariance estimates and destabilize direction-of-arrival (DOA) estimation with multiple signal classification (MUSIC). This study proposes adaptive logarithmic compression MUSIC (ALC-MUSIC) for acoustic arrays operating under time-varying burst interference. Its contribution is an adaptive compression framework that uses noise-subspace drift to detect statistical changes and tunes logarithmic compression parameters through a composite objective based on the Jarque–Bera statistic, skewness, and kurtosis. A dual-branch implementation combines projection approximation subspace tracking based on recursive least squares with exponentially weighted covariance estimation, supporting compression adaptation and MUSIC spectrum estimation. Experiments with a six-element MEMS microphone array tested a 1 kHz target under time-gated broadband Gaussian interference with burst widths of 50 and 100 ms. ALC-MUSIC achieved DOA root mean square errors of 3.1615° and 3.1478°, respectively, with 45.06% and 73.88% of estimates within ±2° of the target direction. The corresponding 90th-percentile absolute errors were 3.61° and 3.85°. These results demonstrate improved estimation stability and higher success rates than the tested MUSIC variants under the investigated burst-interference conditions, supporting adaptive amplitude compression for robust acoustic DOA estimation.