Motoya Hayashi

Dr. Motoya Hayashi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2020 in Environmental Health and Preventive Medicine
Verified
Journal Article
Open access
PDF file
KAKenichi Azuma
Kenichi Azuma
UYU Yanagi
U Yanagi
NKNaoki Kagi
Naoki Kagi
HKHoon Kim
Hoon Kim
MOMasayuki Ogata
Masayuki Ogata
MHMotoya Hayashi
Motoya Hayashi
The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), a new zoonotic agent that emerged in December 2019, causes coronavirus disease 2019 (COVID-19). This infection can be spread by asymptomatic, presymptomatic, and symptomatic carriers. SARS-CoV-2 spreads primarily via respiratory droplets during close person-to-person contact in a closed space, especially a building. This article summarizes the environmental factors involved in SARS-CoV-2 transmission, including a strategy to prevent SARS-CoV-2 transmission in a building environment. SARS-CoV-2 can persist on surfaces of fomites for at least 3 days depending on the conditions. If SARS-CoV-2 is aerosolized intentionally, it is stable for at least several hours. SARS-CoV-2 is inactivated rapidly on surfaces with sunlight. Close-contact aerosol transmission through smaller aerosolized particles is likely to be combined with respiratory droplets and contact transmission in a confined, crowded, and poorly ventilated indoor environment, as suggested by some cluster cases. Although evidence of the effect of aerosol transmission is limited and uncertainty remains, adequate preventive measures to control indoor environmental quality are required, based on a precautionary approach, because COVID-19 has caused serious global damages to public health, community, and the social economy. The expert panel for COVID-19 in Japan has focused on the “3 Cs,” namely, “closed spaces with poor ventilation,” “crowded spaces with many people,” and “close contact.” In addition, the Ministry of Health, Labour and Welfare of Japan has been recommending adequate ventilation in all closed spaces in accordance with the existing standards of the Law for Maintenance of Sanitation in Buildings as one of the initial political actions to prevent the spread of COVID-19. However, specific standards for indoor environmental quality control have not been recommended and many scientific uncertainties remain regarding the infection dynamics and mode of SARS-CoV-2 transmission in closed indoor spaces. Further research and evaluation are required regarding the effect and role of indoor environmental quality control, especially ventilation.

1 November 2020 in Environmental Research
Verified
Journal Article
Closed access
KAKenichi Azuma
Kenichi Azuma
NKNaoki Kagi
Naoki Kagi
HKHoon Kim
Hoon Kim
MHMotoya Hayashi
Motoya Hayashi

22 August 2020 in JAPAN ARCHITECTURAL REVIEW
Verified
Journal Article
Open access
PDF file
MHMotoya Hayashi
Motoya Hayashi
UYU Yanagi
U Yanagi
KAKenichi Azuma
Kenichi Azuma
NKNaoki Kagi
Naoki Kagi
MOMasayuki Ogata
Masayuki Ogata
NKNoriko Kaihara
Noriko Kaihara
Information on air‐conditioning and ventilation has been continuously disseminated in response to the Japanese Government's announcement of the need for appropriate ventilation measures against the new coronavirus disease (COVID‐19), and the issuing of an emergency presidential discourse by the presidents of Engineering Societies. In this paper, we add to the information the latest knowledge on the behavior of SARS‐CoV‐2 in air, describe its diffusion characteristics in the built environment, and summarize the effects of temperature and humidity on the virus. Then we recommend varying approaches of air‐conditioning control for facility type.

2 July 2021 in JAPAN ARCHITECTURAL REVIEW
Verified
Journal Article
Open access
PDF file
TKTakashi Kurabuchi
Takashi Kurabuchi
UYU Yanagi
U Yanagi
MOMasayuki Ogata
Masayuki Ogata
MOMasayuki Otsuka
Masayuki Otsuka
NKNaoki Kagi
Naoki Kagi
STShinichi Tanabe
Shinichi Tanabe
It is still undetermined if the main infection route of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2), the virus that leads to coronavirus disease 2019 (COVID‐19), is infection through droplet, contact, or airborne transmission. However, confined spaces with poor ventilation are cited as a risk factor for group outbreaks, and there is growing interest in the effects of intervention through the appropriate operation of air‐conditioning and sanitary equipment to reduce the risk of airborne transmission. This study first offers an outline of the characteristics of the novel coronavirus disease and the cluster outbreak case reports that have been clarified until now. Subsequently, we describe the appropriate operating conditions for building equipment that are effective in reducing the risk of infection and also highlight specificities for each building use based on the guidance provided by healthcare institutions and with reference to the standard recommendations by Western academic societies related to building equipment.

28 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
MTMori Taro
Mori Taro
TATaisei Akamatsu
Taisei Akamatsu
KKKouhei Kuwabara
Kouhei Kuwabara
MHMotoya Hayashi
Motoya Hayashi
A report released by the WHO indicates that aerosols from infected people are one of the major sources of the spread of COVID-19. Therefore, as the COVID-19 infection caused by the SARS-CoV-2 virus spreads, it has become necessary to reconsider the design and operation of buildings. Inside school buildings in cold regions, not only is it not easy to increase ventilation during the winter, but it may also be difficult for students to attend classes while wearing masks during the summer because such buildings are not equipped with air-conditioning systems. In short, school buildings in cold climates have more problems than those in warm climates. We report on the results of indoor environmental measurement using our developed CO2-concentration meters, a questionnaire survey on students’ feeling of being hot or cold (i.e., ‘thermal sensation’), and a comparison of energy consumption before and after the spread of COVID-19 infection in schools in Sapporo, Japan, a cold-climate area. The results indicate that (1) more than 70% of the students participated in window ventilation by the CO2 meter, and (2) a relatively good indoor environment was maintained through the efforts of teachers and students. However, we also found that (1) 90% of the students felt hot in summer and (2) 40% felt cold in winter, (3) energy efficiency worsened by 7% due to increased ventilation, and (4) air quality was not as clean as desired during the coldest months of the year. Therefore, investment in insulation and air conditioning systems for school buildings is needed.

16 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
JMJunichiro Matsunaga
Junichiro Matsunaga
KKKoki Kikuta
Koki Kikuta
HHHideki Hirakawa
Hideki Hirakawa
KMKeita Mizuno
Keita Mizuno
MTMasaki Tajima
Masaki Tajima
AFAkira Fukushima
Akira Fukushima
In this paper, the authors examined the technology to maximize the use of renewable energy. Passive ventilation systems are expected to reduce the energy consumption of the fan and the maintenance burden. In addition, the wall-mounted solar air heater can supply thermal energy without using any energy at all. Therefore, this paper presents a “passive ventilation system with a solar air heater” that combines a passive ventilation system with the solar air heater to preheat the air. This system can reduce the ventilation load. To evaluate the solar air heater performance in a real environment, we developed a simulation for calculating the heat collection capacity of the solar air heater, and then the system was implemented in a real building for verification. The simulation performs hourly unsteady calculations, allowing for accurate evaluation of the annual simulation. Based on the measurement results, the effects of heating load reduction and prediction methods are presented. The solar air heater reduced the monthly ventilation load by up to 50% or more, and by at least 15%. It was also confirmed that there was a high correlation between the actual measurements and the simulation results.