Koki Kikuta

Dr. Koki Kikuta

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
JMJunichiro Matsunaga
Junichiro Matsunaga
KKKoki Kikuta
Koki Kikuta
HHHideki Hirakawa
Hideki Hirakawa
KMKeita Mizuno
Keita Mizuno
MTMasaki Tajima
Masaki Tajima
AFAkira Fukushima
Akira Fukushima
In this paper, the authors examined the technology to maximize the use of renewable energy. Passive ventilation systems are expected to reduce the energy consumption of the fan and the maintenance burden. In addition, the wall-mounted solar air heater can supply thermal energy without using any energy at all. Therefore, this paper presents a “passive ventilation system with a solar air heater” that combines a passive ventilation system with the solar air heater to preheat the air. This system can reduce the ventilation load. To evaluate the solar air heater performance in a real environment, we developed a simulation for calculating the heat collection capacity of the solar air heater, and then the system was implemented in a real building for verification. The simulation performs hourly unsteady calculations, allowing for accurate evaluation of the annual simulation. Based on the measurement results, the effects of heating load reduction and prediction methods are presented. The solar air heater reduced the monthly ventilation load by up to 50% or more, and by at least 15%. It was also confirmed that there was a high correlation between the actual measurements and the simulation results.

3 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
HYHan Yang
Han Yang
KKKoki Kikuta
Koki Kikuta
MHMotoya Hayashi
Motoya Hayashi
The demand for heating in cold regions drives up carbon emissions every year. In order to achieve China’s carbon neutrality target by 2060, CO2 emissions in the cold regions must be reduced. In this paper, using Design Builder software, a simulation model of residential buildings in severe cold regions was created, and the most appropriate parameter design scheme for carbon emission reduction of residential buildings in severe cold regions was derived by simulating the experimental data of the original parameter design scheme and the changed parameter design scheme, as well as the calculation of carbon dioxide emission reduction rate. In order to make the comparison of the results easier, no change was made in the selection of the changed scheme for the external insulation material, foamed polystyrene panels. The results show that the most suitable parameter scheme for houses in severe cold regions is 85 mm thick foamed polystyrene panels for exterior walls, 200 mm thick foamed polystyrene panels for roofs, and exterior windows should use semi-tempered plastic steel frame and triple glass 6 mm glass + vacuum + 6 mm low-e glass + 12 mm air + 6 mm glass composed of windows. This technique saves 30.32% of energy as compared to the original parameter design approach. The efficiency of energy conservation is 33.03%. The emission reduction effect is significant. The best parametric design plan has a static payback period of 5 years. The best parametric design plan has a discounted payback period of 7 and a net present value of USD 65,413.39. This scheme can provide a great economic return while also increasing the performance of the building.

10 July 2023 in Energies
Verified
Journal Article
Open access
PDF file
HYHan Yang
Han Yang
KKKoki Kikuta
Koki Kikuta
MHMotoya Hayashi
Motoya Hayashi
Since the construction industry is one of China’s high carbon emission industries, to achieve China’s carbon neutrality target by 2060, CO2 emissions in cold regions must be reduced. At the same time, forests have excellent carbon sequestration abilities, so this paper takes residential buildings in severely cold regions as the object of carbon emission reduction research. A model of a two-story building in Changchun was constructed, and the life-cycle carbon emissions of reinforced concrete and wood structures were measured using the life-cycle evaluation method as the basis for calculation and simulation with DesignBuilderVer.7 software. The results show that the life-cycle carbon emission of a wood structure house is 61.46 t less than that of a reinforced concrete house, and the life-cycle carbon emission reduction rate of a wood structure house is 43.39%. Based on the data, it has been proven that wooden structures effectively reduce carbon dioxide emissions during the building life cycle while enhancing building performance, given the same structural conditions.

10 January 2023 in Atmosphere
Verified
Journal Article
Open access
PDF file
MHMotoya Hayashi
Motoya Hayashi
UYU Yanagi
U Yanagi
YHYoshinori Honma
Yoshinori Honma
YYYoshihide Yamamoto
Yoshihide Yamamoto
MOMasayuki Ogata
Masayuki Ogata
STShin-Ichi Tanabe
Shin-Ichi Tanabe
The importance of effective ventilation as one of the measures against COVID-19 is widely recognized worldwide. In Japan, at the early stage of the pandemic, in March 2020, an official announcement was made about basic ventilation measures against COVID-19. WHO also used the term “long-range aerosol or long-range airborne transmission” for the first time in December 2021. Based on the aerosol infection control measures before 2021 by the Japanese government, we conducted experiments on methods related to partition placement as an element of effective ventilation methods. In July 2022, the governmental subcommittee on Novel Coronavirus Disease Control provided an emergent proposal about effective ventilation methods to prevent two types of aerosol infection; infection by large aerosol on the air current and infection by small floating aerosol diffusion in a room. They also showed the way of setting droplet prevention partitions, which do not block off ventilation based on this investigation’s results.

16 July 2022 in Buildings
Verified
Journal Article
Open access
PDF file
HHHideki Hirakawa
Hideki Hirakawa
TUTakeyoshi Uematsu
Takeyoshi Uematsu
AFAkira Fukushima
Akira Fukushima
YAYusuke Adachi
Yusuke Adachi
KKKoki Kikuta
Koki Kikuta
Since the Japanese Building Standards Act was revised in 2000, the installation of steel timber connectors (STCs) to reinforce timber frame (TF) connections has been mandated for new-build TF houses in Japan. However, for the TF houses built before then, more than 40% do not have sufficient STCs and are considered earthquake-prone. This study proposed a simple and easy seismic retrofit technique for such earthquake-prone existing houses. The proposed technique can reinforce TF connections using only plywood and common nails and achieve equivalent performance to the benchmark STCs used in Japanese TF houses, such as the “CP-T type” or the combination of “VP type” and “BP type” STCs. Experiments were performed to compare the proposed technique with the STCs using pullout and full-scale in-plane cyclic tests. The experimental results showed that the proposed technique had a higher seismic performance than the STCs, which was particularly excellent in displacement ductility to prevent a collapse of the TF house without damaging the timbers. The proposed technique will be accepted by many carpenters when retrofitting earthquake-prone existing houses because simple and easy.

9 November 2021 in Preprints.org
Verified
Preprint
Open access
PDF file
JMJunichiro Matsunaga
Junichiro Matsunaga
KKKoki Kikuta
Koki Kikuta
HHHideki Hirakawa
Hideki Hirakawa
KMKeita Mizuno
Keita Mizuno
MTMasaki Tajima
Masaki Tajima
AFAkira Fukushima
Akira Fukushima
This paper, we examined the technology to maximize the use of renewable energy. The passive ventilation system is expected to reduce the energy consumption of the fan power and the maintenance burden. In addition, the wall-mounted solar air heater can supply thermal energy without using any energy at all. Therefore, we propose a "passive ventilation system with a solar air heater" that combines a passive ventilation system with solar air heater to preheat the air supply and reduce the ventilation load. To evaluate the solar air heater performance in a real environment, we developed a simulation for calculating the heat collection capacity of the solar air heater, and then implemented the system in a real building for verification. Based on the measurement results, the effects of heating load reduction and prediction methods are presented.