Fayez Alruwaili

Mr. Fayez Alruwaili


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2021 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
MSMarzieh S. Saeedi-Hosseiny
Marzieh S. Saeedi-Hosseiny
FAFayez Alruwaili
Fayez Alruwaili
SMSean McMillan
Sean McMillan
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
MAMohammad H. Abedin-Nasab
Mohammad H. Abedin-Nasab
In this paper, we design, develop, and validate a surgical robotic system, entitled Robossis, to assist long-bone fracture reduction, i.e., alignment, surgeries. Unlike traditional long-bone fracture surgeries, Robossis enables the surgeon to precisely align the fractured bone in the presence of large traction forces and torques. The proposed surgical system includes a novel 3-armed robot, a bone-gripping mechanism, and a master controller. The 6-DOF 3-armed wide-open parallel robot has a unique architecture, which facilitates positioning the bone inside the robot, providing a large workspace for surgical maneuvers. Kinematic analysis shows that the symmetric 3-armed mechanism provides a significant advantage over the Gough-Stewart platform, i.e., 15 times larger rotational workspace, which is a vital advantage for fracture alignment. Theoretical and experimental testing are performed to demonstrate Robossis performance, including high accuracy and force insertion capabilities. A successful cadaver test was performed using a Robossis prototype, which shows that guided by intraoperative X-ray imaging, Robossis is able to manipulate bone in all translational and rotational directions while encountering the muscle payload surrounding the femur. Robossis is designed to balance accuracy, payload, and workspace, and its innovative design presents major advantages over the existing robot designs for the reduction of long-bone fractures.

26 September 2018 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
FAFayez Alruwaili
Fayez Alruwaili
KCKim Cluff
Kim Cluff
JGJacob Griffith
Jacob Griffith
HFHussam Farhoud
Hussam Farhoud
This paper focuses on the development of a passive, lightweight skin patch sensor that can measure fluid volume changes in the heart in a non-invasive, point-of-care setting. The wearable sensor is an electromagnetic, self-resonant sensor configured into a specific pattern to formulate its three passive elements (resistance, capacitance, and inductance). In an animal model, a bladder was inserted into the left ventricle (LV) of a bovine heart, and fluid was injected using a syringe to simulate stoke volume (SV). In a human study, to assess the dynamic fluid volume changes of the heart in real time, the sensor frequency response was obtained from a participant in a 30° head-up tilt (HUT), 10° HUT, supine, and 10° head-down tilt positions over time. In the animal model, an 80-mL fluid volume change in the LV resulted in a downward frequency shift of 80.16 kHz. In the human study, there was a patterned frequency shift over time which correlated with ventricular volume changes in the heart during the cardiac cycle. Statistical analysis showed a linear correlation ${R} ^{2} = 0.98$ and 0.87 between the frequency shifts and fluid volume changes in the LV of the bovine heart and human participant, respectively. In addition, the patch sensor detected heart rate in a continuous manner with a 0.179% relative error compared to electrocardiography. These results provide promising data regarding the ability of the patch sensor to be a potential technology for SV monitoring in a non-invasive, continuous, and non-clinical setting.

1 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NMNoor Mohammed
Noor Mohammed
KCKim Cluff
Kim Cluff
MSMark Sutton
Mark Sutton
BVBernardo Villafana-Ibarra
Bernardo Villafana-Ibarra
BLBenjamin Loflin
Benjamin Loflin
JDJaydip Desai
Jaydip Desai
Modern wearable devices show promising results in terms of detecting vital bodily signs from the wrist. However, there remains a considerable need for a device that can conform to the human body’s variable geometry to accurately detect those vital signs and to understand health better. Flexible radio frequency (RF) resonators are well poised to address this need by providing conformable bio-interfaces suitable for different anatomical locations. In this work, we develop a compact wearable RF biosensor that detects multisite hemodynamic events due to pulsatile blood flow through noninvasive tissue–electromagnetic (EM) field interaction. The sensor consists of a skin patch spiral resonator and a wearable transceiver. During resonance, the resonator establishes a strong capacitive coupling with layered dielectric tissues due to impedance matching. Therefore, any variation in the dielectric properties within the near-field of the coupled system will result in field perturbation. This perturbation also results in RF carrier modulation, transduced via a demodulator in the transceiver unit. The main elements of the transceiver consist of a direct digital synthesizer for RF carrier generation and a demodulator unit comprised of a resistive bridge coupled with an envelope detector, a filter, and an amplifier. In this work, we build and study the sensor at the radial artery, thorax, carotid artery, and supraorbital locations of a healthy human subject, which hold clinical significance in evaluating cardiovascular health. The carrier frequency is tuned at the resonance of the spiral resonator, which is 34.5 ± 1.5 MHz. The resulting transient waveforms from the demodulator indicate the presence of hemodynamic events, i.e., systolic upstroke, systolic peak, dicrotic notch, and diastolic downstroke. The preliminary results also confirm the sensor’s ability to detect multisite blood flow events noninvasively on a single wearable platform.

1 March 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
MSMarzieh S. Saeedi-Hosseiny
Marzieh S. Saeedi-Hosseiny
FAFayez Alruwaili
Fayez Alruwaili
MCMichael P. Clancy
Michael P. Clancy
ECEmily A. Corson
Emily A. Corson
SMSean McMillan
Sean McMillan
MAMohammad H. Abedin-Nasab
Mohammad H. Abedin-Nasab
This letter presents Robossis, a surgical robotic system for automated femur fracture alignment. Robossis is the integration of an optical tracking system with a 6-degree-of-freedom (6-DOF) 3-armed parallel robot that satisfies the clinical and mechanical design requirements for femur alignment surgery. In real-time, the optical tracking system obtains the spatial position of the distal and proximal parts of the fractured femur. Then, an auto-alignment algorithm uses this data to guide the robot to automatically and accurately align the bone fragments while overcoming the muscle payload surrounding the femur. A graphical user interface (GUI) provides a real-time visual guide for the surgeon to check the deviation from alignment while the robot is automatically bringing the bone into an aligned position. To demonstrate the capabilities of Robossis, laboratory and cadaver experiments are performed, showing that Robossis can successfully manipulate bone in 6 DOFs in space, achieving alignment with submillimeter accuracy.

14 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JGJacob Lee Griffith
Jacob Lee Griffith
KCKim Cluff
Kim Cluff
GDGrant Downes
Grant Downes
BEBrandon Eckerman
Brandon Eckerman
SBSubash Bhandari
Subash Bhandari
NMNoor Mohammed
Noor Mohammed
The alteration of the hydrostatic pressure gradient in the human body has been associated with changes in human physiology, including abnormal blood flow, syncope, and visual impairment. The focus of this study was to evaluate changes in the resonant frequency of a wearable electromagnetic resonant skin patch sensor during simulated physiological changes observed in aerospace applications. Simulated microgravity was induced in eight healthy human participants (n = 8), and the implementation of lower body negative pressure (LBNP) countermeasures was induced in four healthy human participants (n = 4). The average shift in resonant frequency was −13.76 ± 6.49 MHz for simulated microgravity with a shift in intracranial pressure (ICP) of 9.53 ± 1.32 mmHg, and a shift of 8.80 ± 5.2097 MHz for LBNP with a shift in ICP of approximately −5.83 ± 2.76 mmHg. The constructed regression model to explain the variance in shifts in ICP using the shifts in resonant frequency (R2 = 0.97) resulted in a root mean square error of 1.24. This work demonstrates a strong correlation between sensor signal response and shifts in ICP. Furthermore, this study establishes a foundation for future work integrating wearable sensors with alert systems and countermeasure recommendations for pilots and astronauts.

29 August 2023 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
MCMichael Clancy
Michael Clancy
FAFayez Alruwaili
Fayez Alruwaili
MSMarzieh S. Saeedi-Hosseiny
Marzieh S. Saeedi-Hosseiny
SMSean McMillan
Sean McMillan
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
MAMohammad H. Abedin-Nasab
Mohammad H. Abedin-Nasab
Robot-assisted femur repair has been of increased interest in recent literature due to the success of robot-assisted surgeries and current reoperation rates for femur fracture surgeries. The current limitation of robot-assisted femur fracture surgery is the lack of large force generation and sufficient workspace size in traditional mechanisms. To address these challenges, our group has created a 3-RRPS parallel mechanism, Robossis, which maintains the strength of parallel mechanisms while improving the translational and rotational workspace volume. In this paper, an optimal design methodology of parallel mechanisms for application to robot-assisted femur fracture surgery using a single-objective genetic algorithm is proposed. The genetic algorithm will use a single-objective function to evaluate the various configurations based on the clinical and mechanical design criteria for femur fracture surgery as well as the global conditioning index. The objective function is composed of the desired translational and rotational workspaces based on the design criteria, dynamic load-carrying capacity, and the homogeneous Jacobian global conditioning index. Lastly, experimental results of Robossis were obtained to validate the kinematic solution and the mechanism itself; Robossis had an average error of 0.31 mm during experimental force testing.