Sean McMillan

Dr. Sean McMillan


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2022 in Arthroscopy Techniques
Verified
Journal Article
Open access
QCQuincy T. Cheesman
Quincy T. Cheesman
PSPatrick F. Szukics
Patrick F. Szukics
MSMichael Stark
Michael Stark
SKSterling C. Kramer
Sterling C. Kramer
SMSean McMillan
Sean McMillan
The use of biologics and rotator cuff augmentation have seen significant growth in interest to combat complications of rotator cuff retear after arthroscopic rotator cuff repair. Bio‐inductive implants are used to induce new tissue formation; however, they lack structural strength at the time of implantation. Conversely, dermal allografts are used to provide structural strength at implantation, but they do not allow for sufficient tissue incorporation and carry inherent risks of allograft tissue. The BioBrace™ (Biorez, New Haven, CT) is a bio‐inductive scaffold composed of highly porous type I collagen and bio‐resorbable poly ( l ‐lactide) microfilaments developed to combat the latter drawbacks. The unique bio‐composite properties provide the ability to combine the benefits of bio‐induction and strength into a single implant. We propose a successful, reproducible technique for the implantation of BioBrace for rotator cuff augmentation. Technique Video: video See video under supplementary data.

19 November 2021 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
MSMarzieh S. Saeedi-Hosseiny
Marzieh S. Saeedi-Hosseiny
FAFayez Alruwaili
Fayez Alruwaili
SMSean McMillan
Sean McMillan
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
MAMohammad H. Abedin-Nasab
Mohammad H. Abedin-Nasab
In this paper, we design, develop, and validate a surgical robotic system, entitled Robossis, to assist long-bone fracture reduction, i.e., alignment, surgeries. Unlike traditional long-bone fracture surgeries, Robossis enables the surgeon to precisely align the fractured bone in the presence of large traction forces and torques. The proposed surgical system includes a novel 3-armed robot, a bone-gripping mechanism, and a master controller. The 6-DOF 3-armed wide-open parallel robot has a unique architecture, which facilitates positioning the bone inside the robot, providing a large workspace for surgical maneuvers. Kinematic analysis shows that the symmetric 3-armed mechanism provides a significant advantage over the Gough-Stewart platform, i.e., 15 times larger rotational workspace, which is a vital advantage for fracture alignment. Theoretical and experimental testing are performed to demonstrate Robossis performance, including high accuracy and force insertion capabilities. A successful cadaver test was performed using a Robossis prototype, which shows that guided by intraoperative X-ray imaging, Robossis is able to manipulate bone in all translational and rotational directions while encountering the muscle payload surrounding the femur. Robossis is designed to balance accuracy, payload, and workspace, and its innovative design presents major advantages over the existing robot designs for the reduction of long-bone fractures.

1 March 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
MSMarzieh S. Saeedi-Hosseiny
Marzieh S. Saeedi-Hosseiny
FAFayez Alruwaili
Fayez Alruwaili
MCMichael P. Clancy
Michael P. Clancy
ECEmily A. Corson
Emily A. Corson
SMSean McMillan
Sean McMillan
MAMohammad H. Abedin-Nasab
Mohammad H. Abedin-Nasab
This letter presents Robossis, a surgical robotic system for automated femur fracture alignment. Robossis is the integration of an optical tracking system with a 6-degree-of-freedom (6-DOF) 3-armed parallel robot that satisfies the clinical and mechanical design requirements for femur alignment surgery. In real-time, the optical tracking system obtains the spatial position of the distal and proximal parts of the fractured femur. Then, an auto-alignment algorithm uses this data to guide the robot to automatically and accurately align the bone fragments while overcoming the muscle payload surrounding the femur. A graphical user interface (GUI) provides a real-time visual guide for the surgeon to check the deviation from alignment while the robot is automatically bringing the bone into an aligned position. To demonstrate the capabilities of Robossis, laboratory and cadaver experiments are performed, showing that Robossis can successfully manipulate bone in 6 DOFs in space, achieving alignment with submillimeter accuracy.

17 October 2021 in Journal of Orthopaedic Experience & Innovation
Verified
Journal Article
Open access
PDF file
SMSean McMillan
Sean McMillan
RARobert Arciero
Robert Arciero
EFElizabeth Ford
Elizabeth Ford
Rotator cuff repair (RCR) is one of the most common arthroscopic orthopedic procedures performed worldwide. A high number of clinical and subclinical re-tears exist post procedure, particularly in the subset group of large (>3cm) to massive tears and revision tears (Agrawal 2012; Galatz et al. 2004; Djurasovic et al. 2001; Burkhart et al. 2007). Advances in RCR over the past two decades have nearly eliminated failures related to implant failure. Currently the most common mechanism of failure lies in suture “pull through” at the suture-tendon interface (Mirzayan et al. 2019; Ponce et al. 2013; Ma et al. 2006). The addition of rotator cuff augmentation has seen significant growth, with improved outcomes rates compared to non-augmented repairs. However, each of the most commonly used synthetic and biologic augmentation options have drawbacks. We describe the current overview of RCR augmentation and introduce a novel bio-composite scaffold featuring a highly porous type I collagen scaffold reinforced with bio-resorbable poly(L-Lactide) (PLLA) microfilaments. This scaffold is intended for the reinforcement of soft-tissue repair and uniquely combines bio-inductive properties with load-sharing strength.

3 November 2022 in JSES Reviews, Reports, and Techniques
Verified
Journal Article
Open access
BFBrian Fliegel
Brian Fliegel
DDDennis DeBernardis
Dennis DeBernardis
EFElizabeth Ford
Elizabeth Ford
PFPaul Favorito
Paul Favorito
SMSean McMillan
Sean McMillan
Glenoid bone loss presents a challenging dilemma, particularly in the setting of failed arthroplasty requiring conversion to a reverse total shoulder arthroplasty (rTSA). The aim of our systematic review was to examine the success and failure of biologic glenoid bone grafting to address vault deficiencies in the setting of shoulder arthroplasty conversion to rTSA. Twelve articles were included and a complete PUBMED search. Inclusion criteria included glenoid bone grafting for conversion of failed arthroplasty and a minimum of 12 months follow-up. Exclusion criteria included grafting for primary rTSA, and re-revision for infection or humeral loosening. Failures were defined as failure of the graft to radiographically incorporate, symptomatic base plate loosening, and need for further surgical re-revision. Two hundred patients were identified across the 12 articles. Eighteen percent (36/200) of all cases demonstrated failure to radiographically incorporate. Thirteen percent (25/200) of all grafting cases required re-revision due to symptomatic failure (pain or functional deterioration). Femoral shaft demonstrated the highest failure rate at 88% (7/8). Grafting for glenoid bone loss in the setting of conversion to rTSA has an 82% rate of success across autograft and allograft utilization. Further studies are needed to better define the success of autografting versus allografting in the setting of shoulder arthroplasty conversion to rTSA with glenoid bone loss.

29 August 2023 in Journal of Mechanisms and Robotics
Verified
Journal Article
Closed access
PDF file
MCMichael Clancy
Michael Clancy
FAFayez Alruwaili
Fayez Alruwaili
MSMarzieh S. Saeedi-Hosseiny
Marzieh S. Saeedi-Hosseiny
SMSean McMillan
Sean McMillan
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
MAMohammad H. Abedin-Nasab
Mohammad H. Abedin-Nasab
Robot-assisted femur repair has been of increased interest in recent literature due to the success of robot-assisted surgeries and current reoperation rates for femur fracture surgeries. The current limitation of robot-assisted femur fracture surgery is the lack of large force generation and sufficient workspace size in traditional mechanisms. To address these challenges, our group has created a 3-RRPS parallel mechanism, Robossis, which maintains the strength of parallel mechanisms while improving the translational and rotational workspace volume. In this paper, an optimal design methodology of parallel mechanisms for application to robot-assisted femur fracture surgery using a single-objective genetic algorithm is proposed. The genetic algorithm will use a single-objective function to evaluate the various configurations based on the clinical and mechanical design criteria for femur fracture surgery as well as the global conditioning index. The objective function is composed of the desired translational and rotational workspaces based on the design criteria, dynamic load-carrying capacity, and the homogeneous Jacobian global conditioning index. Lastly, experimental results of Robossis were obtained to validate the kinematic solution and the mechanism itself; Robossis had an average error of 0.31 mm during experimental force testing.