qiujie wang

qiujie wang

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YLYulong Liu
Yulong Liu
TJTao Jin
Tao Jin
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed
QWqiujie wang
qiujie wang
Power quality events caused by renewable-energy integration are usually associated with complex disturbances; therefore, their type identification is the primary task of subsequent pollution control. This study proposes a novel three-step classification approach based on time-dependent spectral features (TDSFs) for the classification of complex power quality disturbances (PQDs). First, the improved complete ensemble empirical mode decomposition with adaptive noise (ICEEMDAN) is adopted to decompose the PQDs into several intrinsic mode functions (IMFs). The related IMFs are selected by correlation coefficient and kurtosis. Then the eight eigenvalues of each IMF are extracted, including TDSFs. Finally, the eigenvalue dimension of each IMF is reduced by linear discriminant analysis (LDA). Moreover, the classifier of the adaptive $k$ -nearest neighbor with excluding outliers (AdaKNNEO) can confirm the PQDs type. To verify the effectiveness of the proposed approach, a series of simulations and hardware experiments are conducted. The overall result shows robustness and high accuracy of the proposed method, and especially for the complex PQDs, it possesses the highest entirely correct of 96% compared to other advanced methods.

10 August 2021 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
HTHong Tan
Hong Tan
ZRZhouyang Ren
Zhouyang Ren
WYWei Yan
Wei Yan
QWqiujie wang
qiujie wang
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed
With the increase in wind generation installed capacity, the uncertainty of wind power has brought great challenges to wind power accommodation. The accurate assessment result of wind power accommodation capability (WPAC) has important guiding significance to the formulation of the day-ahead wind power trading plan for the multi-energy microgrid (MEMG). This paper proposes a WPAC assessment method for the MEMG. A liner energy flow model is first derived based on the equivalent infinitesimal replacement and the mild assumption that supply temperatures of different heat load nodes are nearly the same. Then, the operational risk model easily embedded into the assessment model is established based on the probability distributions of prediction error corresponding to multiple wind power output ranges. Finally, the WPAC assessment model is constructed as a two-stage robust optimization problem and solved by the column-and-constraint generation (C&CG) algorithm. Simulations on a MEMG composed of the IEEE 33-bus power system and the 23-node district heating network (DHN) verify the effectiveness of the proposed method.

2 June 2022 in Energy
Verified
Journal Article
Closed access
HTHong Tan
Hong Tan
WYWei Yan
Wei Yan
ZRZhouyang Ren
Zhouyang Ren
QWqiujie wang
qiujie wang
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed

24 February 2021 in IEEE Systems Journal
Verified
Journal Article
Closed access
QWqiujie wang
qiujie wang
TJTao Jin
Tao Jin
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed
The speed and robustness of fault section location directly affect the resilience of the distribution network when the latter is exposed to extreme events. This article is proposing a fast and robust fault section location method for distribution system considering the outage reports from smart meters in low-voltage network and notifications from remote fault indicators (RFIs) in medium-voltage network. To make section location faster, a proposed location model moves underreporting variables and misreporting variables to offline recognition. To make section location more robust, the location model proposes new constraints of expected RFI states to remove the limitation of multiple faults on different paths to all sources. Simulation results on a utility feeder with distributed generations demonstrate that the proposed method has faster location and better robustness, which is helpful to the resilience enhancement of the distribution network.

6 November 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
QWqiujie wang
qiujie wang
TJTao Jin
Tao Jin
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed
TCTing Chen
Ting Chen
Fault diagnosis has a critical role in maintaining the reliability and stability of distribution networks. Compared with common diagnosis methods, such as expert systems that depend on the professional experience and information of fault; the model-based diagnosis (MBD) has many distinct advantages. However, the efficiency and accuracy of the calculation of the minimum hitting set (MHS) limit the performance of MBD. To overcome these limitations, an MHS algorithm with a pre-judging mechanism is proposed in this paper. This mechanism is constructed based on the distribution characteristics of MHS. The use of this mechanism prior to MHS calculation enables the removal of most non-HS particles and all super-MHS particles and enables compression of the MHS calculation solution space several times. Moreover, after compression, only two types of particles remain in the left solution space, which are non-HS and MHS. As a result, the MHS can be picked out directly through the HS fitness function and the HS criterion and avoiding the participation of the MHS ensured strategy (MHSES). Three cases studies have been introduced to test the effect of the pre-judging mechanism on the performance of the MHS calculation. In addition, a discussion on MBD of the distribution networks has been presented to validate the efficiency and accuracy of the proposed algorithm.

24 March 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
QWqiujie wang
qiujie wang
TJTao Jin
Tao Jin
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed
Dipankar DebDipankar Deb
Dipankar Deb
The existing four linear section location methods are all established based on the three-phase fault current direction. When a single-phase grounding fault occurs in a neutral noneffectively grounded system, these methods are no longer applicable. This study proposes a linear optimization method for section location suitable for single-phase ground fault in the neutral noneffectively grounded system. It presents an improved transient zero-sequence current direction identification algorithm based on line voltage to accurately determine a transient zero-sequence current direction under single-phase grounding faults without zero-sequence voltage information. Second, it proposes a suitable linear section location model for single-phase ground faults as per the transient zero-sequence current direction’s distribution characteristics after the single-phase ground fault. Finally, it is verified in different feeders that the proposed method can quickly and accurately locate the fault section after the single-phase ground fault occurs in the neutral-point ineffectively grounded distribution system.