Mixed-oxide transition-metal aerogels (AGLs), particularly manganese-based AGLs, have attracted considerable interest over the past decade owing to their extraordinary properties, including high porosity, good surface area, and ultralow density. To develop easy and lightweight materials for the ever-increasing energy storage demands of the near future, we designed a novel Mn-based electrode material to meet these rising requirements. MnO/Mn2O3 AGLs were synthesized using a novel borohydride hydrolysis method and then annealed at 200, 400, and 550 °C. The as-synthesized AGLs yielded flower-like network structures, but their porosity increased with increasing temperatures, to a high temperature of 400 °C. This increased porosity and network structure facilitate a high capacitance. A supercapacitor (SC) constructed with the three-electrode material yielded 230 F/g for the MnAGL@400 sample, followed by yields from the MnAGL@200 and MnAGL@550 electrodes. Furthermore, the device constructed with MnAGL@400 exhibited an energy density of 9.8 Wh/kg and a power density of ~16,500 W/kg at a current density of 20 A/g. The real-time applicability of the AGL was demonstrated by engineering a two-electrode device employing MnAGL@400 as the positive electrode, which exhibited 97% capacity retention and 109% Coulombic efficiency over 20,000 cycles.
D-penicillamine (PA) is a sulfur group-containing drug prescribed for various health issues, but overdoses have adverse effects. Therefore, regular, selective, and sensitive sensing is essential to reduce the need for further treatment. In this study, diphenylamine (DPA) was electropolymerized in an aqueous acidic medium. The PA detection sensitivity, selectivity, and limit of detection were enhanced by electropolymerizing DPA on an electrochemically reduced graphene oxide (ERGO)/glassy carbon (GC) surface. The formation of p-DPA and ERGO was investigated using various techniques. The as-prepared p-DPA@ERGO/GC revealed the excellent redox-active (N–C to N=C) sites of p-DPA. The p-DPA@ERGO/GC electrode exhibited excellent electrochemical sensing ability towards PA determination because of the presence of the –NH–functional moiety and effective interactions with the –SH group of PA. The p-DPA@ERGO/GC exhibited a high surface coverage of 9.23 × 10−12 mol cm−2. The polymer-modified p-DPA@ERGO/GC electrode revealed the amperometric determination of PA concentration from the 1.4 to 541 μM wide range and the detection limit of 0.10 μM. The real-time feasibility of the developed p-DPA@ERGO/GC electrode was tested with a realistic PA finding in human blood serum samples and yielded a good recovery of 97.5–101.0%, confirming the potential suitability in bio-clinical applications.