Verónica Barroso-García

Dr. Verónica Barroso-García

University of Valladolid, Valladolid, Castille-Leon, Spain
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2021 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
FVFernando Vaquerizo-Villar
Fernando Vaquerizo-Villar
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
LKLeila Kheirandish-Gozal
Leila Kheirandish-Gozal
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
Verónica Barroso-GarcíaVerónica Barroso-García
Verónica Barroso-García
Roberto HorneroRoberto Hornero
Roberto Hornero
This study aims at assessing the usefulness of deep learning to enhance the diagnostic ability of oximetry in the context of automated detection of pediatric obstructive sleep apnea (OSA). A total of 3196 blood oxygen saturation (SpO 2 ) signals from children were used for this purpose. A convolutional neural network (CNN) architecture was trained using 20-min SpO 2 segments from the training set (859 subjects) to estimate the number of apneic events. CNN hyperparameters were tuned using Bayesian optimization in the validation set (1402 subjects). This model was applied to three test sets composed of 312, 392, and 231 subjects from three independent databases, in which the apnea-hypopnea index (AHI) estimated for each subject (AHI CNN ) was obtained by aggregating the output of the CNN for each 20-min SpO 2 segment. AHI CNN outperformed the 3% oxygen desaturation index (ODI3), a clinical approach, as well as the AHI estimated by a conventional feature-engineering approach based on multi-layer perceptron (AHI MLP ). Specifically, AHI CNN reached higher four-class Cohen's kappa in the three test databases than ODI3 (0.515 vs 0.417, 0.422 vs 0.372, and 0.423 vs 0.369) and AHI MLP (0.515 vs 0.377, 0.422 vs 0.381, and 0.423 vs 0.306). In addition, our proposal outperformed state-of-the-art studies, particularly for the AHI severity cutoffs of 5 e/h and 10 e/h. This suggests that the information automatically learned from the SpO 2 signal by deep-learning techniques helps to enhance the diagnostic ability of oximetry in the context of pediatric OSA.

24 March 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
ACAna Cerezo-Hernández
Ana Cerezo-Hernández
ACAndrea Crespo
Andrea Crespo
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
FVFernando Vaquerizo-Villar
Fernando Vaquerizo-Villar
FCFélix del Campo
Félix del Campo
The most appropriate physiological signals to develop simplified as well as accurate screening tests for obstructive sleep apnoea (OSA) remain unknown. This study aimed at assessing whether joint analysis of at-home oximetry and airflow recordings by means of machine-learning algorithms leads to a significant diagnostic performance increase compared to single-channel approaches. Consecutive patients showing moderate-to-high clinical suspicion of OSA were involved. The apnoea-hypopnoea index (AHI) from unsupervised polysomnography was the gold standard. Oximetry and airflow from at-home polysomnography were parameterised by means of 38 time, frequency, and non-linear variables. Complementarity between both signals was exhaustively inspected via automated feature selection. Regression support vector machines were used to estimate the AHI from single-channel and dual-channel approaches. A total of 239 patients successfully completed at-home polysomnography. The optimum joint model reached 0.93 (95%CI 0.90–0.95) intra-class correlation coefficient between estimated and actual AHI. Overall performance of the dual-channel approach (kappa: 0.71; 4-class accuracy: 81.3%) significantly outperformed individual oximetry (kappa: 0.61; 4-class accuracy: 75.0%) and airflow (kappa: 0.42; 4-class accuracy: 61.5%). According to our findings, oximetry alone was able to reach notably high accuracy, particularly to confirm severe cases of the disease. Nevertheless, oximetry and airflow showed high complementarity leading to a remarkable performance increase compared to single-channel approaches. Consequently, their joint analysis via machine learning enables accurate abbreviated screening of OSA at home.

1 March 2018 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
FVFernando Vaquerizo-Villar
Fernando Vaquerizo-Villar
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
LKLeila Kheirandish-Gozal
Leila Kheirandish-Gozal
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
Verónica Barroso-GarcíaVerónica Barroso-García
Verónica Barroso-García
Roberto HorneroRoberto Hornero
Roberto Hornero

1 November 2018 in Physiological Measurement
Verified
Journal Article
Closed access
PDF file
FVFernando Vaquerizo-Villar
Fernando Vaquerizo-Villar
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
LKLeila Kheirandish-Gozal
Leila Kheirandish-Gozal
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
Verónica Barroso-GarcíaVerónica Barroso-García
Verónica Barroso-García
Roberto HorneroRoberto Hornero
Roberto Hornero
Objective : To evaluate whether detrended fluctuation analysis (DFA) provides information that improves the diagnostic ability of the oximetry signal in the diagnosis of paediatric sleep apnoea–hypopnoea syndrome (SAHS). Approach : A database composed of 981 blood oxygen saturation (SpO 2 ) recordings in children was used to extract DFA-derived features in order to quantify the scaling behaviour and the fluctuations of the SpO 2 signal. The 3% oxygen desaturation index ( ODI 3) was also computed for each subject. Fast correlation-based filter (FCBF) was then applied to select an optimum subset of relevant and non-redundant features. This subset fed a multi-layer perceptron (MLP) neural network to estimate the apnoea–hypopnoea index (AHI). Main results : ODI 3 and four features from the DFA reached significant differences associated with the severity of SAHS. An optimum subset composed of the slope in the first scaling region of the DFA profile and the ODI 3 was selected using FCBF applied to the training set (60% of samples). The MLP model trained with this feature subset showed good agreement with the actual AHI, reaching an intra-class correlation coefficient of 0.891 in the test set (40% of samples). Furthermore, the estimated AHI showed high diagnostic ability, reaching an accuracy of 82.7%, 81.9%, and 91.1% using three common AHI cut-offs of 1, 5, and 10 events per hour (e h −1 ), respectively. These results outperformed the overall performance of ODI 3. Significance : DFA may serve as a reliable tool to improve the diagnostic performance of oximetry recordings in the evaluation of paediatric patients with symptoms suggestive of SAHS.

17 June 2017 in Entropy
Verified
Journal Article
Open access
PDF file
ACAndrea Crespo
Andrea Crespo
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
FVFernando Vaquerizo-Villar
Fernando Vaquerizo-Villar
Verónica Barroso-GarcíaVerónica Barroso-García
Verónica Barroso-García
FCFélix del Campo
Félix del Campo
Untreated paediatric obstructive sleep apnoea syndrome (OSAS) can severely affect the development and quality of life of children. In-hospital polysomnography (PSG) is the gold standard for a definitive diagnosis though it is relatively unavailable and particularly intrusive. Nocturnal portable oximetry has emerged as a reliable technique for OSAS screening. Nevertheless, additional evidences are demanded. Our study is aimed at assessing the usefulness of multiscale entropy (MSE) to characterise oximetric recordings. We hypothesise that MSE could provide relevant information of blood oxygen saturation (SpO2) dynamics in the detection of childhood OSAS. In order to achieve this goal, a dataset composed of unattended SpO2 recordings from 50 children showing clinical suspicion of OSAS was analysed. SpO2 was parameterised by means of MSE and conventional oximetric indices. An optimum feature subset composed of five MSE-derived features and four conventional clinical indices were obtained using automated bidirectional stepwise feature selection. Logistic regression (LR) was used for classification. Our optimum LR model reached 83.5% accuracy (84.5% sensitivity and 83.0% specificity). Our results suggest that MSE provides relevant information from oximetry that is complementary to conventional approaches. Therefore, MSE may be useful to improve the diagnostic ability of unattended oximetry as a simplified screening test for childhood OSAS.

7 December 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
FVFernando Vaquerizo-Villar
Fernando Vaquerizo-Villar
Daniel AlvarezDaniel Alvarez
Daniel Alvarez
LKLeila Kheirandish-Gozal
Leila Kheirandish-Gozal
Gonzalo Gutiérrez-TobalGonzalo Gutiérrez-Tobal
Gonzalo Gutiérrez-Tobal
Verónica Barroso-GarcíaVerónica Barroso-García
Verónica Barroso-García
Roberto HorneroRoberto Hornero
Roberto Hornero
The gold standard for pediatric sleep apnea hypopnea syndrome (SAHS) is overnight polysomnography, which has several limitations. Thus, simplified diagnosis techniques become necessary. The aim of this study is twofold: (i) to analyze the blood oxygen saturation (SpO2) signal from nocturnal oximetry by means of features from the wavelet transform in order to characterize pediatric SAHS; (ii) to evaluate the usefulness of the extracted features to assist in the detection of pediatric SAHS. 981 SpO2 signals from children ranging 2–13 years of age were used. Discrete wavelet transform (DWT) was employed due to its suitability to deal with non-stationary signals as well as the ability to analyze the SAHS-related low frequency components of the SpO2 signal with high resolution. In addition, 3% oxygen desaturation index (ODI3), statistical moments and power spectral density (PSD) features were computed. Fast correlation-based filter was applied to select a feature subset. This subset fed three classifiers (logistic regression, support vector machines (SVM), and multilayer perceptron) trained to determine the presence of moderate-to-severe pediatric SAHS (apnea-hypopnea index cutoff ≥ 5 events per hour). The wavelet entropy and features computed in the D9 detail level of the DWT reached significant differences associated with the presence of SAHS. All the proposed classifiers fed with a selected feature subset composed of ODI3, statistical moments, PSD, and DWT features outperformed every single feature. SVM reached the highest performance. It achieved 84.0% accuracy (71.9% sensitivity, 91.1% specificity), outperforming state-of-the-art studies in the detection of moderate-to-severe SAHS using the SpO2 signal alone. Wavelet analysis could be a reliable tool to analyze the oximetry signal in order to assist in the automated detection of moderate-to-severe pediatric SAHS. Hence, pediatric subjects suffering from moderate-to-severe SAHS could benefit from an accurate simplified screening test only using the SpO2 signal.