The economic design of fixed-tilt photovoltaic (PV) plants depends on the coupling between array geometry, inverter saturation, installed direct-current capacity, and cash-flow structure. This study develops an hourly techno-economic framework to jointly optimize fixed tilt angle and DC/AC ratio for three grid-connected PV archetypes: residential prosumer, commercial rooftop, and utility-scale systems. The technical model combines solar position, plane-of-array transposition, cell-temperature correction, balance-of-system losses, inverter efficiency, clipping, and thermal derating. The financial model converts annual AC energy into 25-year equity value using capital expenditure, O&M, debt amortization, depreciation, tariff escalation, and module degradation. The design grid covers tilt angles from 0° to 22° and DC/AC ratios from 1.05 to 1.49. Recommended designs must satisfy tilt ≥8°, performance ratio ≥84%, and clipping-related curtailment ≤2%. After applying these filters, preferred designs converge to 8° tilt with DC/AC ratios of 1.23, 1.29, and 1.27 for the residential, commercial, and utility cases, respectively. The utility-scale recommended design yields 87.14 GWh in year 1, 40.64 MUSD NPV, 23.72% IRR, 0.0445 USD/kWh LCOE, 84.94% PR, and 1.84% curtailment.