This study examines the impact of Inverter-Based Distributed Generators (IIDGs) on short-circuit currents detected by the main relay at the head of a radial feeder. It highlights how changes in fault currents induced by these inverter technologies can significantly affect the effectiveness and reliability of network protection systems. Key variables, such as the level of IIDGs penetration and the relative location of faults with respect to the relay, have been identified as influential factors. The significance of these findings lies in their contribution to a deeper understanding of how inverter fault responses and the integration of IIDGs alter fault currents. To mitigate the adverse effects associated with the insertion of IIDGs, a fault-detection and tripping strategy based on the inverse-time overcurrent curve is proposed. The suggested strategies not only improve fault detection accuracy but also ensure an appropriate response to variations in network conditions.
In this paper, a signal processing method based on Mathematical Morphology (MM) is developed, designed to extract representative characteristics of signals that allow the identification and detection of various types of faults in distribution network feeders that incorporate distributed generation with inverter interfaces (IIDG). The goal is to improve the performance of the fault protection system, ensuring rapid, sensitive, and reliable detection. The fault detection method presented in this article employs a well-known signal processing filter, called the morphological median filter (MMF), applied to the current measured at the current transformer (CT) associated with the relay located at the head of a feeder in a medium-voltage distribution network with IIDG. The extracted characteristics will be used in future research to detect and classify events, such as short-circuit faults or operational manoeuvres, thus facilitating the implementation of protection strategies.
1 January 2026 in IET Generation, Transmission & Distribution
Short‐term scheduling of islanded microgrids with high renewable penetration must reconcile uncertainty, operating cost and post‐contingency dynamic feasibility. This paper presents a sequential optimisation‐simulation framework that integrates field‐calibrated dynamic‐security assessment with multistage stochastic dispatch. MVMO first identifies the PowerFactory dynamic parameters from synchrophasor records; correlated multivariate chronicles then represent demand and renewable uncertainty; and steady‐state and RMS simulations determine the event‐conditioned capability of the network and the grid‐forming BESS. A security compiler converts the signed BESS trajectories into directional power and stored‐energy margins, while a native Object Pascal extension of the SimSEE BESS actor enforces those margins before each stage cost is evaluated. Consequently, the optimiser searches within a security‐qualified feasible set instead of producing an economic schedule that is screened afterwards. An ex‐post reliability‐worth layer values the selected coverage percentile without assigning an artificial security penalty to the dispatch objective. The Baltra–Santa Cruz study comprises 65,000 audited state—event cases and a separate 30,000‐case fault campaign. The calibrated frequency and voltage RMSEs are 53.5 mHz and p.u. At , the upward/downward reserve requirements are 3.66/4.07 MW in Baltra and 1.83/2.03 MW in Santa Cruz. Across 100 aligned chronicles, the unconstrained and schedules for the same assets incur mean thermal‐generation costs of $3568 per day and $4777 per day, respectively, while the latter retains an 82.7% renewable share. On the common RMS holdout, the proportion of dynamically insecure states decreases from 42% for the unconstrained schedule and 9% for a static‐SCED reserve to 0% for the RMS‐informed schedule.
This paper assesses the voltage ride-through (VRT) performance of a 1 MW grid-following photovoltaic (PV) plant connected to the IEEE 13-node unbalanced distribution feeder. Unbalanced RMS simulations in DIgSILENT PowerFactory 2024 SP5A (x64) consider single-phase-to-ground, phase-to-phase, and three-phase faults at the point of common coupling, as well as intentional islanding supported by a 3.5 MVA synchronous diesel generator. Under grid-connected operation, the PV plant remains connected for all simulated faults; the symmetrical three-phase case satisfies the Category-B ARCONEL-001/24 VRT envelope, while the asymmetric cases reveal phase-dependent behavior and temporary healthy-phase overvoltages. During islanding, the synchronous generator establishes the voltage and frequency reference, allowing the GFL PV plant to recover stable operation. The island frequency peaks at 60.929 Hz and settles near 60.664 Hz, both within the 59–61 Hz unlimited-operation band used as a regulatory reference. The results emphasize the importance of unbalanced modeling and grid-forming capability in inverter-rich distribution networks.
El artículo presenta una propuesta para la focalización del subsidio tarifa de la dignidad en los usuarios residenciales de las empresas de distribución de energía eléctrica del Ecuador. Para la focalización se utiliza la técnica de agrupación de datos considerando las características técnicas, geográficas y socioeconómicas de los usuarios. El artículo describe el proceso necesario para recopilar, depurar y procesar los datos a fin de que puedan ser utilizados para la focalización del subsidio. Luego, se detalla el proceso necesario para emparejar los datos y consolidarlos en una sola base de datos de usuarios residenciales. En una siguiente fase, se define una ecuación de pobreza que considera, de manera ponderada, las características técnicas y socioeconómicas de los usuarios y que permite calcular su nivel de pobreza individual. Luego, se describe la forma de agrupar a los usuarios según su nivel de pobreza, así como la manera de establecer la mejor cantidad de grupos que se deben generar de entre los usuarios. Finalmente, el artículo presenta una propuesta metodológica general para focalizar el subsidio tarifa de la dignidad en el Ecuador. El presente artículo presenta los resultados de la focalización del subsidio tarifa de la dignidad aplicada a los usuarios residenciales del Distrito Metropolitano de Quito.
Distributed generation (DG) interconnection in radial distribution networks is often evaluated through voltage-based hosting-capacity studies that lead to binary accept/reject decisions. This paper evaluates a two-stage optimal-power-flow (OPF)–machine-learning framework for rapid pre-feasibility screening. A revised AC optimal power flow (OPF) scenario set contains 20,000 cases spanning 21 candidate DG buses, active-power injections up to 1.8 MW, and loading factors from 0.45 to 1.10. Of 19,930 solver-successful cases, 12,300 satisfy the 0.95–1.05 p.u. engineering voltage criterion and 7630 are non-compliant. In Stage 1, a decision-tree classifier separates feasible and non-compliant cases using categorical DG location, P_DG, and loading factor α, achieving 97.41% accuracy, 97.91% F1-score, 96.37% specificity, and receiver operating characteristic area under the curve (ROC-AUC) = 0.9908 under stratified 10-fold cross-validation. In Stage 2, only feasible scenarios are passed to regression surrogates that predict the signed optimal reactive-power setpoint Q_DG*. The neural network achieves a coefficient of determination (R2) = 0.9996, root mean square error (RMSE) = 4.745 kVAr, and mean absolute error (MAE) = 1.964 kVAr. Surrogate inference requires microseconds per scenario compared with an average OPF solution time of 0.146 s. The framework is intended as a controlled pre-screening benchmark and does not replace detailed three-phase interconnection studies.