Verónica Rosero

Dr. Verónica Rosero


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
VRVerónica Rosero
Verónica Rosero
SPSebastián Salazar Pérez
Sebastián Salazar Pérez
Francisco Gonzalez-LongattFrancisco Gonzalez-Longatt
Francisco Gonzalez-Longatt
ESEduardo J. Salazar
Eduardo J. Salazar
LPLe Nam Hai Pham
Le Nam Hai Pham
EOEduardo Orduña
Eduardo Orduña
This study examines the impact of Inverter-Based Distributed Generators (IIDGs) on short-circuit currents detected by the main relay at the head of a radial feeder. It highlights how changes in fault currents induced by these inverter technologies can significantly affect the effectiveness and reliability of network protection systems. Key variables, such as the level of IIDGs penetration and the relative location of faults with respect to the relay, have been identified as influential factors. The significance of these findings lies in their contribution to a deeper understanding of how inverter fault responses and the integration of IIDGs alter fault currents. To mitigate the adverse effects associated with the insertion of IIDGs, a fault-detection and tripping strategy based on the inverse-time overcurrent curve is proposed. The suggested strategies not only improve fault detection accuracy but also ensure an appropriate response to variations in network conditions.

18 November 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
LPLe Nam Hai Pham
Le Nam Hai Pham
VRVerónica Rosero
Verónica Rosero
ASAnup Shukla
Anup Shukla
Francisco Gonzalez-LongattFrancisco Gonzalez-Longatt
Francisco Gonzalez-Longatt
VMVIVIANA ALEJANDRA MEZA
VIVIANA ALEJANDRA MEZA
Towards the decarbonisation of the power system, digital substations have gradually increased in smart grids, where Ethernet cables have replaced large quantities of copper wires. With this transition, the standardised communication protocols through the LAN network play a central role in exchanging information and data between the physical power system and the control centres. One of the well-known protocols in the digital substations is IEC 61850 GOOSE (Generic Object-Oriented Substation Event), which is used to share time-critical information related to protection, automation, and control. The transmission time of this protocol affects power system operation and raises various issues, such as communication latencies and incorrect information. Therefore, it is necessary to consider the protocol transmission time for further protection and control mechanisms to ensure the stability and efficiency of the power system. For this purpose, this paper contributes the implementation of a cyber–physical power system (CPPS) testbed to measure the transfer time of IEC 61850 GOOSE under the real-time domain using the real-time simulator, Typhoon HIL, and its toolchains. This paper can benefit scholars and researchers in the relevant domains in implementing a CPPS testbed and an approach for transfer time measurement of communication protocols within the laboratory, eliminating the need for real-world substation devices.

18 November 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
VRVerónica Rosero
Verónica Rosero
LPLe Nam Hai Pham
Le Nam Hai Pham
SPSebastián Salazar Pérez
Sebastián Salazar Pérez
Francisco Gonzalez-LongattFrancisco Gonzalez-Longatt
Francisco Gonzalez-Longatt
EOEduardo Orduña
Eduardo Orduña
In this paper, a signal processing method based on Mathematical Morphology (MM) is developed, designed to extract representative characteristics of signals that allow the identification and detection of various types of faults in distribution network feeders that incorporate distributed generation with inverter interfaces (IIDG). The goal is to improve the performance of the fault protection system, ensuring rapid, sensitive, and reliable detection. The fault detection method presented in this article employs a well-known signal processing filter, called the morphological median filter (MMF), applied to the current measured at the current transformer (CT) associated with the relay located at the head of a feeder in a medium-voltage distribution network with IIDG. The extracted characteristics will be used in future research to detect and classify events, such as short-circuit faults or operational manoeuvres, thus facilitating the implementation of protection strategies.

18 November 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
LPLe Nam Hai Pham
Le Nam Hai Pham
VRVerónica Rosero
Verónica Rosero
Francisco Gonzalez-LongattFrancisco Gonzalez-Longatt
Francisco Gonzalez-Longatt
Overcurrent protection is a fundamental aspect of power system protection and is widely utilised in distribution networks. The increasing integration of renewable energy sources (RESs) into the conventional power system has introduced operating challenges due to the variability in fault directions. As a result, protection engineers must not only adjust basic parameters such as pickup current or time delay, but also carefully evaluate the directional protection to align with specific protection objectives and the devices being protected. The complexity of considering multiple aspects in the protection system design can pose challenges for operators in configuring their settings. Therefore, it is necessary to have a systematic approach for protection system design. For this purpose, this paper proposes a methodology for protection system design focusing on directional overcurrent protection setting configuration with detailed implementation. A well-known distribution network, the CIGRE European (EU) medium-voltage (MV) benchmark network, is used to test and validate the proposed methodology with the support of DIgSILENT PowerFactory version 2023 SP1. This article provides a useful document for the configuration of overcurrent protection systems in order to prepare for the challenges arising from the high integration of RESs in the future grid.