Evaggelia Aissopou

Dr. Evaggelia Aissopou


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2015 in American Journal of Hypertension
Verified
Journal Article
Closed access
PDF file
Evaggelia AissopouEvaggelia Aissopou
Evaggelia Aissopou
AAAntonios Argyris
Antonios Argyris
ENEfthimia G. Nasothimiou
Efthimia G. Nasothimiou
GKGeorge D. Konstantonis
George D. Konstantonis
KTKostas Tampakis
Kostas Tampakis
Athanase D. ProtogerouAthanase D. Protogerou
Athanase D. Protogerou
BACKGROUND Arterial stiffness measured under static conditions reclassifies significantly cardiovascular (CV) risk and associates with narrower retinal arterioles. However, arterial stiffness exhibits circadian variation, thus single static stiffness recordings do not correspond to the “usual” 24hr, awake, and asleep average arterial stiffness. We aimed to test the hypothesis that ambulatory 24hr, awake, and asleep aortic (a) pulse wave velocity (PWV) associate with retinal vessel calibers, independently of confounders and of static arterial stiffness, in hypertensive individuals free from diabetes and CV disease. METHODS Digital retinal images were obtained (181 individuals, age: 53.9±10.7 years, 55.2% men) and retinal vessel calibers were measured with validated software to determine central retinal arteriolar and venular equivalents (CRAE and CRVE, respectively); ambulatory (24hr, awake, asleep) and static office aPWV were estimated by Mobil-O-Graph; and static office carotid to femoral (cf) PWV by SphygmoCor. RESULTS Regression analysis performed in 320 gradable retinal images showed that, after adjustment for confounders: (i) ambulatory aPWV was significantly associated with narrower retinal arterioles but not with venules; (ii) asleep aPWV had stronger associations with CRAE than awake aPWV; (iii) both ambulatory aPWV and cfPWV were associated mutually independently with narrower retinal arterioles; aPWV introduction in the model of cfPWV, improved model’s R 2 (P = 0.012). Similar discriminatory ability of 24hr aPWV and of cfPWV to detect the presence of retinal arteriolar narrowing was found. CONCLUSION Ambulatory aPWV, estimated by an operator-independent method, provides additional information to cfPWV regarding the associations of arterial stiffness with the retinal vessel calibers.

24 January 2023 in Ocular Immunology and Inflammation
Verified
Journal Article
Closed access
NMNikos N. Markomichelakis
Nikos N. Markomichelakis
Evaggelia AissopouEvaggelia Aissopou
Evaggelia Aissopou
KCKlio I. Chatzistefanou
Klio I. Chatzistefanou
To describe the long-term prevalence of ocular complications and visual prognosis in patients with pediatric uveitis.Demographics, etiology and location of uveitis, type of complications, treatment...

1 February 2015 in The Journal of Rheumatology
Verified
Journal Article
Closed access
PDF file
Evaggelia AissopouEvaggelia Aissopou
Evaggelia Aissopou
VBVasiliki-Kalliopi Bournia
Vasiliki-Kalliopi Bournia
Athanase D. ProtogerouAthanase D. Protogerou
Athanase D. Protogerou
SPStylianos Panopoulos
Stylianos Panopoulos
TPTheodoros G. Papaioannou
Theodoros G. Papaioannou
PSPetros P. Sfikakis
Petros P. Sfikakis
Objective A primary endothelial cell dysfunction is thought to be involved in systemic sclerosis (SSc)-associated fibroproliferative vasculopathy of the microcirculation and small arterioles, even in sites not affected by fibrosis. Because the role of fibroblasts in pathologic modifications and vascular wall remodeling is relatively unclear, and because the retina provides a unique opportunity to assess microcirculation in the absence of resident fibroblasts, we systematically evaluated retinal vessels in patients with SSc. Methods Digital retinal images were obtained from both eyes of 93 consecutive patients with fully characterized SSc and 29 healthy controls matched 1:1 for age and sex with selected patients without diabetes, hypertension history, or antihypertensive treatment. Internal microvascular calibers (erythrocyte column width in μm) by central retinal arteriolar and venular equivalents and arteriolar to venular ratio were measured using validated software. Results Arteriolar and venular calibers were similar in patients and their matched controls (mean ± SEM; 187 ± 2 vs 184 ± 3, p = 0.444, and 211 ± 2 vs 216 ± 3, p = 0.314, respectively). Both arteriolar and venular calibers and their ratio in patients with SSc were not associated with disease duration, extent of skin involvement, pulmonary fibrosis, digital ulcers or pitting scars, amputations, digital capillaroscopic findings, inflammatory indices, or autoantibodies. Conclusion The evidence that retinal microcirculation is spared in SSc suggests that fibroproliferative vasculopathy may depend on specific cellular or soluble factors not present in the retinal environment.

21 May 2021 in Indian Journal Of Ophthalmology
Verified
Journal Article
Open access
CFChrysoula Florou
Chrysoula Florou
Evaggelia AissopouEvaggelia Aissopou
Evaggelia Aissopou
ECEvangelia Chalkiadaki
Evangelia Chalkiadaki
KAKonstantinos Andreanos
Konstantinos Andreanos
CKChrysanthi Koutsandrea
Chrysanthi Koutsandrea
IGIlias Georgalas
Ilias Georgalas
Purpose: The aim of this study was to evaluate the morphological properties of corneal endothelial cells and central corneal thickness (CCT) in patients with neurofibromatosis type 1 (NF1) and to compare them with age-matched healthy controls. Methods: Nineteen NF1 patients and 38 healthy individuals were recruited. All participants underwent complete ophthalmological examination as well as noncontact specular microscopy to measure endothelial cell density (ECD), average cell area (AVG), coefficient of variation of cell area (CV), the percentage of hexagonal cells, and CCT. Eyes with previous ocular trauma, inflammation or surgery, and preexisting corneal and ocular surface diseases were excluded. Results: NF1 patients had higher ECD compared to healthy controls of the same age (2764.2 ± 270.4 versus 2570.4 ± 449.2 cells/mm2, respectively), although at a borderline level (P = 0.051). Patients with NF1 presented significantly lower CV and AVG when compared to controls (32.9 ± 4.6 versus 37.8 ± 9.5%, P = 0.011 and 364.9 ± 34.4 versus 406.0 ± 107.4 μm2, P = 0.038, respectively). The NF1 group had significantly higher hexagonality in comparison with controls (55.7 ± 6.5 versus 50.5 ± 9.9%, P = 0.025). CCT was similar between the two groups (P = 0.955). Conclusion: Our results show that corneal endothelium has more favorable morphological characteristics in NF1 patients compared to healthy individuals of the same age.

17 February 2023 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
Evaggelia AissopouEvaggelia Aissopou
Evaggelia Aissopou
Athanase D. ProtogerouAthanase D. Protogerou
Athanase D. Protogerou
PTPanagiotis Theodossiadis
Panagiotis Theodossiadis
PSPetros P. Sfikakis
Petros P. Sfikakis
ICIrini Chatziralli
Irini Chatziralli
Purpose: To investigate the alterations of retinal vessel diameters in patients with macular edema secondary to retinal vein occlusion (RVO), before and after treatment with intravitreal ranibizumab. Methods: Digital retinal images were obtained from 16 patients and retinal vessel diameters were measured before and three months after treatment with intravitreal ranibizumab with validated software to determine central retinal arteriolar and venular equivalents, as well as arteriolar to venular ratio. Results: In 17 eyes of 16 patients with macular edema secondary to RVO (10 with branch RVO and 6 with central RVO) aged 67 ± 10.2 years, we found that diameters of both retinal arterioles and venules were significantly decreased after intravitreal ranibizumab treatment. Specifically, the central retinal arteriolar equivalent was 215.2 ± 11.2 μm at baseline and 201.2 ± 11.1 μm at month 3 after treatment (p < 0.001), while the central retinal venular equivalent was 233.8 ± 29.6 μm before treatment versus 207.6 ± 21.7 μm at month 3 after treatment (p < 0.001). Conclusions: A significant vasoconstriction in both retinal arterioles and venules in patients with RVO was found at month 3 after intravitreal ranibizumab treatment compared to baseline. This could be of clinical importance, since the degree of vasoconstriction might be an early marker of treatment efficacy, compatible with the idea that hypoxia is the major trigger of VEGF in RVO. Further studies should be conducted to confirm our findings.

11 May 2026 in Reports
Verified
Journal Article
Open access
PDF file
LAZAROS YOFOGLULAZAROS YOFOGLU
LAZAROS YOFOGLU
GZGEORGIOS ZERVAS
GEORGIOS ZERVAS
CKChristina Konstantaki
Christina Konstantaki
CΜChrysoula Μoustou
Chrysoula Μoustou
Evaggelia AissopouEvaggelia Aissopou
Evaggelia Aissopou
AAAntonios Argyris
Antonios Argyris
Objectives: The aim of this study was to compare a widely applied table-top digital non-mydriatic camera (Topcon TRC-NW-8) with a handheld digital non-mydriatic camera (Optomed Aurora IQ) regarding the quantitative assessment of the retinal microcirculation using established biomarkers: central retinal arteriolar equivalent (CRAE), central retinal venular equivalent (CRVE) and arterio-venous ratio (AVR). Methods: The present cross-sectional study included 26 randomly selected participants (51 eyes) who underwent retinal imaging of both eyes with the two devices and were analyzed using a static retinal vessel analyzer. Results: The mean differences in CRAE, CRVE and AVR between the two devices (Topcon/Aurora) were 24.96 ± 11.7, 22.7 ± 11.7 and 0.026 ± 0.045, respectively. Strong correlations were observed between devices (r = 0.84 for CRAE, 0.75 for CRVE and 0.83 for AVR; all p < 0.001), with high agreement as indicated by ICC values (0.91, 0.85, and 0.90, respectively). Bland–Altman plots indicated evidence of systemic bias (95% within 2 SD) with no proportional bias, as the differences were consistently distributed across the range of average values. Regression-based equations were derived to approximate the transformation of measurements between devices. Conclusions: The handheld fundus camera demonstrates strong correlation and good relative agreement with the table-top device; however, a consistent device-dependent bias limits the direct interchangeability of absolute measurements. The derived transformation equations may facilitate approximate cross-device comparison, although external validation is required. These findings support the complementary use of handheld devices and highlight the need for calibration strategies when integrating measurements across platforms.