LAZAROS YOFOGLU

Dr. LAZAROS YOFOGLU

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2023 in Hypertension
Verified
Journal Article
Closed access
PDF file
LAZAROS YOFOGLULAZAROS YOFOGLU
LAZAROS YOFOGLU
FKFotios Karachalias
Fotios Karachalias
Marios K GeorgakisMarios K Georgakis
Marios K Georgakis
CTChristos Tountas
Christos Tountas
AAAntonios Argyris
Antonios Argyris
Athanase D. ProtogerouAthanase D. Protogerou
Athanase D. Protogerou
Background: Pressure wave reflections (PWRs) within the circulation are assessed at various arterial sites by various noninvasive methods. We aimed at reviewing the conflicting data regarding the hypothesis that higher PWRs are associated with higher left ventricular mass and tested whether this association stands for all available indices of PWRs, all (proximal or distal to the heart) sites of assessment, and is modified by sex, age and heart rate. Methods: Based on a predefined protocol applying the Meta-Analysis of Observational Studies in Epidemiology (MOOSE) guidelines, we identified eligible for meta-analysis data regarding: augmentation index, augmentation pressure, backward pressure (Pb), reflection index, and their association with left ventricular mass index (19 studies, total population n=8686). Results: We found statistically significant associations, independent from blood pressure level, for all indices of PWRs at all arterial sites (carotid augmentation index; odds ratio; standardized beta coefficient [β]: 0.14 [95% CI, 0.07% to 0.21%], per SD increase), radial augmentation index (β: 0.21; 0.11 to 0.31), central augmentation pressure (β: 0.15; 0.03 to 0.27), central Pb (β: 0.23; 0.05 to 0.42), and central reflection index (β: 0.14; 0.06 to 0.22), except for aortic augmentation index as estimated by generalized transfer functions. Meta-regression analysis showed that the association between carotid augmentation index and left ventricular mass was higher among populations with higher heart rate ( P =0.036, beta: 0.017 [95% CI, 0.001 to 0.033]) and tended to be higher in middle-aged ( P =0.07, beta: −0.001; −0.021 to 0.001). Conclusions: A clinically meaningful association between PWRs and left ventricular mass, assessed at either central or peripheral arterial sites by most available methods was shown, suggesting that PWR reduction strategies might be useful. Based on the present evidence, such trials should target middle-aged populations with high normal heart rate.

23 December 2024 in Hypertension Research
Verified
Journal Article
Closed access
PDF file
EAElpida Athanasopoulou
Elpida Athanasopoulou
FKFotios Karachalias
Fotios Karachalias
LAZAROS YOFOGLULAZAROS YOFOGLU
LAZAROS YOFOGLU
PKPanagiotis Kanatas
Panagiotis Kanatas
KDKathrin Danninger
Kathrin Danninger
Athanase D. ProtogerouAthanase D. Protogerou
Athanase D. Protogerou

19 April 2025 in American Journal of Hypertension
Verified
Journal Article
Open access
FKFotios Karachalias
Fotios Karachalias
LAZAROS YOFOGLULAZAROS YOFOGLU
LAZAROS YOFOGLU
Nikolaos KakaletsisNikolaos Kakaletsis
Nikolaos Kakaletsis
KGKonstantinos Grammatopoulos
Konstantinos Grammatopoulos
AAAntonios Argyris
Antonios Argyris
Athanase D. ProtogerouAthanase D. Protogerou
Athanase D. Protogerou
BACKGROUND: Augmentation index (Aix) is a widely used index of pressure wave reflections (PWRs) derived from noninvasive blood pressure waves recordings and pulse wave analysis. Cerebral small vessel disease (cSVD) comprises various pathological processes affecting the brain’s microvasculature and is a major cause of vascular cognitive impairment, ischemic, and hemorrhagic stroke. This meta-analysis aimed to assess the association between PWRs, as measured by AIx, and cSVD as identified through neuroimaging biomarkers, and to explore potential differences based on arterial site of AIx measurement. METHODS: Following a predefined protocol adhering to the Meta-Analysis of Observational Studies in Epidemiology guidelines, nine studies comprising a total of 6,774 participants were included. Pooled effect estimates were calculated to evaluate the relationship between AIx and cSVD markers, including white matter hyperintensities (WMH). RESULTS: A marginal positive association was observed between AIx and cSVD [central (carotid and aortic) AIx: β=0.04 (95% CI: 0.01-0.07) per SD increase; carotid AIx: β=0.05 (95% CI: 0.00-0.09); aortic AIx: β=0.03 (95% CI: 0.00-0.06)]. Similar results were found for the association between AIx and WMH [central (carotid and aortic) AIx: β=0.05 (95% CI: 0.01-0.08); carotid AIx: β=0.05 (95% CI: 0.00-0.10); aortic AIx: β=0.05 (95% CI: 0.00-0.010)]. CONCLUSIONS: AIx showed a marginal positive association with cSVD, but the clinical relevance remains unclear. Substantial heterogeneity across studies, along with the absence of data on other PWR indices, limits the robustness and generalizability of these findings. Future research should employ advanced methodologies capable of assessing local PWR coefficients to better elucidate the relationship between PWRs and brain microcirculation.

23 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LAZAROS YOFOGLULAZAROS YOFOGLU
LAZAROS YOFOGLU
Evaggelia AissopouEvaggelia Aissopou
Evaggelia Aissopou
PSPetros P. Sfikakis
Petros P. Sfikakis
ICIrini Chatziralli
Irini Chatziralli
Kalliopi KaratziKalliopi Karatzi
Kalliopi Karatzi
AAAntonios Argyris
Antonios Argyris
Background: Caffeine, dairy products and other food items may influence retinal microcirculation. Retinal microvascular indices provide quantitative biomarkers of systemic microvascular health and are increasingly used in clinical and research settings. The aim of this study was to elucidate the possible effects of these food products on structural and functional indices of the retinal microcirculation. Methods: Based on a registered protocol, we identified eligible interventional/observational studies examining the association of these factors with retinal biomarkers, including central retinal artery equivalent (CRAE), central retinal vein equivalent (CRVE), arteriolar-to-venular diameter ratio (AVR), retinal vascular tortuosity, vessel diameter index (VDI) and retinal vessel flicker light-induced dilation (FID). Results: Fourteen studies were included addressing caffeine (4), dairy products (2) and other food (9) consumption. Acutely, caffeine intake was dose-dependently associated with narrowed CRAE, CRVE, decreased VDI and increased AVR and FID. Long-term, caffeine consumption was associated with larger CRVE and lower AVR, while decaffeinated coffee with larger CRAE and AVR and narrower CRVE. Low-fat dairy products, fish and fiber were associated with larger CRAE, smaller CRVE, and increased AVR, while red meat consumption was associated with narrower CRAE and lower AVR. Increased salt intake was associated with increased venular tortuosity, while almond consumption was associated with larger CRVE. Owing to substantial study heterogeneity, a meta-analysis was not feasible. Conclusions: Potentially clinically meaningful associations between food groups and retinal indices were identified. These associations should be considered when evaluating retinal microcirculation and assessing CVD risk since modification of these factors may be beneficial for the cardiovascular system.

11 May 2026 in Reports
Verified
Journal Article
Open access
PDF file
LAZAROS YOFOGLULAZAROS YOFOGLU
LAZAROS YOFOGLU
GZGEORGIOS ZERVAS
GEORGIOS ZERVAS
CKChristina Konstantaki
Christina Konstantaki
CΜChrysoula Μoustou
Chrysoula Μoustou
Evaggelia AissopouEvaggelia Aissopou
Evaggelia Aissopou
AAAntonios Argyris
Antonios Argyris
Objectives: The aim of this study was to compare a widely applied table-top digital non-mydriatic camera (Topcon TRC-NW-8) with a handheld digital non-mydriatic camera (Optomed Aurora IQ) regarding the quantitative assessment of the retinal microcirculation using established biomarkers: central retinal arteriolar equivalent (CRAE), central retinal venular equivalent (CRVE) and arterio-venous ratio (AVR). Methods: The present cross-sectional study included 26 randomly selected participants (51 eyes) who underwent retinal imaging of both eyes with the two devices and were analyzed using a static retinal vessel analyzer. Results: The mean differences in CRAE, CRVE and AVR between the two devices (Topcon/Aurora) were 24.96 ± 11.7, 22.7 ± 11.7 and 0.026 ± 0.045, respectively. Strong correlations were observed between devices (r = 0.84 for CRAE, 0.75 for CRVE and 0.83 for AVR; all p < 0.001), with high agreement as indicated by ICC values (0.91, 0.85, and 0.90, respectively). Bland–Altman plots indicated evidence of systemic bias (95% within 2 SD) with no proportional bias, as the differences were consistently distributed across the range of average values. Regression-based equations were derived to approximate the transformation of measurements between devices. Conclusions: The handheld fundus camera demonstrates strong correlation and good relative agreement with the table-top device; however, a consistent device-dependent bias limits the direct interchangeability of absolute measurements. The derived transformation equations may facilitate approximate cross-device comparison, although external validation is required. These findings support the complementary use of handheld devices and highlight the need for calibration strategies when integrating measurements across platforms.