GEORGIOS ZERVAS

Dr. GEORGIOS ZERVAS


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 May 2024
Verified
Conference Paper
Closed access
EKEfstathios Kastritis
Efstathios Kastritis
DBDimitrios Bampatsias
Dimitrios Bampatsias
GGGeorgios Georgiopoulos
Georgios Georgiopoulos
DDDimitrios Delialis
Dimitrios Delialis
LALasthenis Angelidakis
Lasthenis Angelidakis
KSKimon Stamatelopoulos
Kimon Stamatelopoulos
**Author Listing - Lead/ Submitting Author (we will be communicating with this individual): Name, Institution, City and State where the work was | POSTER

11 May 2026 in Reports
Verified
Journal Article
Open access
PDF file
LAZAROS YOFOGLULAZAROS YOFOGLU
LAZAROS YOFOGLU
GZGEORGIOS ZERVAS
GEORGIOS ZERVAS
CKChristina Konstantaki
Christina Konstantaki
CΜChrysoula Μoustou
Chrysoula Μoustou
Evaggelia AissopouEvaggelia Aissopou
Evaggelia Aissopou
AAAntonios Argyris
Antonios Argyris
Objectives: The aim of this study was to compare a widely applied table-top digital non-mydriatic camera (Topcon TRC-NW-8) with a handheld digital non-mydriatic camera (Optomed Aurora IQ) regarding the quantitative assessment of the retinal microcirculation using established biomarkers: central retinal arteriolar equivalent (CRAE), central retinal venular equivalent (CRVE) and arterio-venous ratio (AVR). Methods: The present cross-sectional study included 26 randomly selected participants (51 eyes) who underwent retinal imaging of both eyes with the two devices and were analyzed using a static retinal vessel analyzer. Results: The mean differences in CRAE, CRVE and AVR between the two devices (Topcon/Aurora) were 24.96 ± 11.7, 22.7 ± 11.7 and 0.026 ± 0.045, respectively. Strong correlations were observed between devices (r = 0.84 for CRAE, 0.75 for CRVE and 0.83 for AVR; all p < 0.001), with high agreement as indicated by ICC values (0.91, 0.85, and 0.90, respectively). Bland–Altman plots indicated evidence of systemic bias (95% within 2 SD) with no proportional bias, as the differences were consistently distributed across the range of average values. Regression-based equations were derived to approximate the transformation of measurements between devices. Conclusions: The handheld fundus camera demonstrates strong correlation and good relative agreement with the table-top device; however, a consistent device-dependent bias limits the direct interchangeability of absolute measurements. The derived transformation equations may facilitate approximate cross-device comparison, although external validation is required. These findings support the complementary use of handheld devices and highlight the need for calibration strategies when integrating measurements across platforms.