Modified blind bolts (Hollo-Bolt) and a locally strengthened steel tube column in the panel zone were created to overcome the moment-resisting problem for the bolted connections between concrete-filled hollow section columns and open section beams and to enhance the performance of connections. The cyclic loading was conducted on a total of six modified anchored blind bolted flush end-plate connections to concrete-filled steel tube (CFST) columns. The key parameters investigated were the tube wall thickness, end-plate thickness, blind bolt anchorage method, and beam section. The failure mode, hysteretic behavior, strength, stiffness, ductility, and energy dissipation capacity of the connections were analyzed and evaluated with all details. The results indicated that connections with modified anchored blind bolts and locally strengthened steel tubes could avoid the premature failure of CFST column and exhibit an improved behavior with a favorable strength, stiffness, and stiffness degradation. The test observations reveal two representative failure modes, and the tube wall thickness and blind bolt anchorage method have a significant effect on the resultant failure mode. Moreover, the use of thin endplate and weak beam can effectively enhance the hysteretic behavior of joints, ductility, and energy dissipation capacity; and the change in anchoring method has little effect on the stiffness. Finite element (FE) analysis models were established for the aforementioned connections. The numerical models were validated against the experimental results and exhibited good agreement. Finally, based on the component method, an initial stiffness calculation method was established for the connections.
1 November 2017 in Construction and Building Materials
As the square steel tube in the tension zone is always the weakest part of moment-resisting joints, modified blind bolts (Hollo-Bolts) and a locally strengthened steel tube in the panel zone were adopted to enhance the joint performance. Cyclic loading tests were carried out on eight anchored blind-bolted extended end-plate joints between square concrete-filled steel tube (CFST) columns and steel beams. The test parameters included the end-plate thickness, steel tube wall thickness, beam section size, local strengthening connection method, blind bolt anchorage method, and stiffeners. The failure mode, hysteretic behavior, stiffness, strength, ductility, strength degradation, stiffness degradation, and energy dissipation capacity of the joints were studied and analyzed. The test results showed that the application of anchored blind bolts and a locally strengthened steel tube can fully utilize the bolt strength and significantly improve the joint performance, especially in terms of strength and strength degradation. The test observations revealed three typical failure modes for the joints, and the failure mode depended on the weakest component. In addition, the local reinforcement of C-channel and change in the anchorage method had a limited effect on the initial stiffness. Greater end-plate thickness and the use of stiffeners significantly increased the joint stiffness and decreased the rate of stiffness degradation. The use of stiffeners also significantly enhanced the ductility and energy dissipation by moving plastic hinge outward from the joints. Finally, finite element analysis (FEA) models were developed and validated against the experimental results, and the stress distribution and force transfer pattern were investigated.
22 January 2018 in Advances in Mechanical Engineering
The semi-rigid performance of minor-axis connections is important in the study of overall framework. Experiments were conducted on minor-axis flush end-plate connections under a monotonic load. Numerical simulations were carried out using the finite-element package ABAQUS and compared with the experimental results. The initial rotational stiffness of the connection was calculated using the equivalent T-stub in tension and EC3 component method, and the calculated veracity is discussed. The results show that under the action of a negative bending moment, the failure modes of the minor-axis flush end-plate connection are the out-of-plane bending deformation of the end-plate, local buckling of the bottom flange of the beam, and bending deformation of the bolts. The minor-axis flush end-plate connection is a typical semi-rigid connection. However, the deformations of the flush end-plate could not be accurately calculated using the equivalent T-stub in the tension of EC3 methods. The initial rotational stiffness calculated using the method was much larger than that obtained using the experiment and finite-element analysis. The equivalent simulation is not appropriate if the out-of-plane bending stiffness of the flush end-plate is not obtained accurately.
With decades of research, semi-rigid beam-to-column connections have been widely accepted. However, most studies have been restricted to the local connection level, leaving system-oriented analysis and design methods with a meager investigation, which leads to the fact that the active use of semi-rigid connections in practice is rare. This study aims to provide a system-level design method to bridge the gap between element and connection design, and the two main contributions are to propose a method for designing semi-rigid steel frames by pre-establishing a performance-based connection database and to formulate refined classification criteria for connection performance levels. In this method, the frame design is transformed into finding an appropriate matching of performance requirements between elements and connections. The classification criteria for connection performance levels are based on the assumption that the structural responses (stability, resistance, and deformation) are only slightly affected by the properties of connections within the same level. The emphasis is on the rotational stiffness and moment resistance of the connection. Finally, the results of examples indicate that the connection database is portable and can be applied to various frames, avoiding the repetitive design for connections in different projects. In addition, tuning the performance requirements of the connection can greatly reduce the number of design variables compared to tuning its geometry, and more importantly, it provides designers with a clearer update path, which can significantly shorten the process of trial-and-error and quickly arrive at the final design.