In order to examine the seismic behavior of high-strength steel extended end-plate connections, a three-dimensional efficient finite-element model in Abaqus was established subjected to cyclic loading at the beam end. Geometrical dimensions, boundary conditions, element types, contact properties between the bolts, end-plate and column flange, and material cyclic constitutive models were described in detail. Geometry and material nonlinearity were adequately considered. In particular, a cyclic plasticity model for high-strength steels was employed that was easily calibrated based on the tension coupon test, so as to describe the complicated cyclic hardening and softening response. The simulated results of the finite-element model were compared to the test ones in terms of both deformation modes and hysteresis loops. The results showed that the bending deformation of the end-plate and column flange was accurately captured, and the gap phenomena among the bolt nuts, the end-plate, and column flange was described in a satisfactory manner as well. The hysteresis loops from the simulation agreed well with the test results, reproducing the pinched shape due to the end-plate gap evolution under cyclic loading as well as the quite plump shape with stable energy dissipation when the panel zone dominated the cyclic response. Therefore, the accuracy of the finite-element model was verified and it provided a strong benchmark tool for investigating the cyclic or seismic performance of this kind of connection. The connection failure including the bolt fracture and cracking in the end-plate needs further numerical study by calibrating accurate material failure models for high-strength steels and bolts.
Modified blind bolts (Hollo-Bolt) and a locally strengthened steel tube column in the panel zone were created to overcome the moment-resisting problem for the bolted connections between concrete-filled hollow section columns and open section beams and to enhance the performance of connections. The cyclic loading was conducted on a total of six modified anchored blind bolted flush end-plate connections to concrete-filled steel tube (CFST) columns. The key parameters investigated were the tube wall thickness, end-plate thickness, blind bolt anchorage method, and beam section. The failure mode, hysteretic behavior, strength, stiffness, ductility, and energy dissipation capacity of the connections were analyzed and evaluated with all details. The results indicated that connections with modified anchored blind bolts and locally strengthened steel tubes could avoid the premature failure of CFST column and exhibit an improved behavior with a favorable strength, stiffness, and stiffness degradation. The test observations reveal two representative failure modes, and the tube wall thickness and blind bolt anchorage method have a significant effect on the resultant failure mode. Moreover, the use of thin endplate and weak beam can effectively enhance the hysteretic behavior of joints, ductility, and energy dissipation capacity; and the change in anchoring method has little effect on the stiffness. Finite element (FE) analysis models were established for the aforementioned connections. The numerical models were validated against the experimental results and exhibited good agreement. Finally, based on the component method, an initial stiffness calculation method was established for the connections.
As the square steel tube in the tension zone is always the weakest part of moment-resisting joints, modified blind bolts (Hollo-Bolts) and a locally strengthened steel tube in the panel zone were adopted to enhance the joint performance. Cyclic loading tests were carried out on eight anchored blind-bolted extended end-plate joints between square concrete-filled steel tube (CFST) columns and steel beams. The test parameters included the end-plate thickness, steel tube wall thickness, beam section size, local strengthening connection method, blind bolt anchorage method, and stiffeners. The failure mode, hysteretic behavior, stiffness, strength, ductility, strength degradation, stiffness degradation, and energy dissipation capacity of the joints were studied and analyzed. The test results showed that the application of anchored blind bolts and a locally strengthened steel tube can fully utilize the bolt strength and significantly improve the joint performance, especially in terms of strength and strength degradation. The test observations revealed three typical failure modes for the joints, and the failure mode depended on the weakest component. In addition, the local reinforcement of C-channel and change in the anchorage method had a limited effect on the initial stiffness. Greater end-plate thickness and the use of stiffeners significantly increased the joint stiffness and decreased the rate of stiffness degradation. The use of stiffeners also significantly enhanced the ductility and energy dissipation by moving plastic hinge outward from the joints. Finally, finite element analysis (FEA) models were developed and validated against the experimental results, and the stress distribution and force transfer pattern were investigated.
In the past few decades, semi-rigid connections have been studied extensively; several major international steel structure design specifications have incorporated this component into their own systems. However, there is still no appropriate way to integrate the semi-rigid joint design into the structural design more efficiently. The forward design method of introducing joint characteristics into the frame by predetermining joint details requires considerable effort to trial massive amounts of variables, which is undoubtedly a nightmare for those structures composed of thousands of members and joints. In this paper, a feasible method for the reversed design of semi-rigid steel frames has been developed. Being similar to the traditional one, the structural design is still divided into member design and joint design. In the member design phase, a joint is abstracted as a performance parameter and its details are no longer concerned. Then, in the joint design phase, the joint details can be reconstructed subject to the joint required performance by using the optimization algorithm. Throughout the process, engineers simply tune the desired properties of the joins rather than their construction geometry, which results in clearer tuning direction and improved solution efficiency. In addition, determining how to choose a good, required connection stiffness as the starting design is discussed and recommendations are given. Finally, two examples are solved to verify the effectiveness of the proposed method.
With decades of research, semi-rigid beam-to-column connections have been widely accepted. However, most studies have been restricted to the local connection level, leaving system-oriented analysis and design methods with a meager investigation, which leads to the fact that the active use of semi-rigid connections in practice is rare. This study aims to provide a system-level design method to bridge the gap between element and connection design, and the two main contributions are to propose a method for designing semi-rigid steel frames by pre-establishing a performance-based connection database and to formulate refined classification criteria for connection performance levels. In this method, the frame design is transformed into finding an appropriate matching of performance requirements between elements and connections. The classification criteria for connection performance levels are based on the assumption that the structural responses (stability, resistance, and deformation) are only slightly affected by the properties of connections within the same level. The emphasis is on the rotational stiffness and moment resistance of the connection. Finally, the results of examples indicate that the connection database is portable and can be applied to various frames, avoiding the repetitive design for connections in different projects. In addition, tuning the performance requirements of the connection can greatly reduce the number of design variables compared to tuning its geometry, and more importantly, it provides designers with a clearer update path, which can significantly shorten the process of trial-and-error and quickly arrive at the final design.
The bolted angle connections which are simple, fast, cost-effective, high quality, and no site welding have been recognized as their excellent performance. The moment-rotation behavior of both major and minor axis should be both taken into considering, however, the lack of research on minor axis limits the more comprehensive application. Five monotonic tests were carried out to investigate the influence under different parameters, and a new type connection were considered and detailed. Refined finite element models were built to validate the experimental results and to do several parametric analyses on initial rotational stiffness and plastic moment resistance, including of a presence of stiffened seat angle, angle thickness, and prying force. Furthermore, a new simplified plate method was proposed for calculating stiffness of stiffened angle and web in bending. The stiffened angle gives a significant increase at the moment-resisting capacity and the initial stiffness, the ultimate rotation of all tested specimens was beyond 0.067rad. The initial stiffness and plastic moment resistance of the joints were also controlled by the column web. The presence of the stiffener in the compression zone has the none effect on initial stiffness. The numerical analysis has captured the failure reason for weld and more attention should be paid to welding of stiffener in engineering design and practice. Adding stiffener at the top-and-seat angle joint can reduce the prying force of bolt, but it still cannot be ignored. The theoretical results were in good agreement with the experimental data and finite element results; therefore, it can be used to guide the design and selection of joints.