Hamid Reza Kokabi

Prof. Hamid Reza Kokabi


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
AOAla Eldin Omer
Ala Eldin Omer
George ShakerGeorge Shaker
George Shaker
SSSafieddin Safavi-Naeini
Safieddin Safavi-Naeini
KNKieu Ngo
Kieu Ngo
RSRaed Shubair
Raed Shubair
HKHamid Reza Kokabi
Hamid Reza Kokabi
This paper presents a high-sensitive planar microwave sensor based on the metamaterial technology, integrated with a microfluidic channel to be used for liquid sensing in a variety of biomedical applications. The sensor design comprises three cells of circular complementary split ring resonators (CSRRs) engraved on the ground plane of a dielectric substrate in a cascaded configuration. The sensing cells are excited with a time-varying electric field coupled from a planar microstrip-line (MTL) etched on the bottom side of the substrate. The proposed design of multiple coupled resonators would enhance the electric field intensity over a larger sensing region through the inter-resonator coupling, thus improving the overall sensitivity for detecting liquid samples of high permittivity and dielectric losses. The sensor exhibits a reject (band stop) filter behaviour with multiple resonances in the centimeter-wave band 1 – 6 GHz when loaded symmetrically with liquid samples. The sensor is fabricated on an FR4 dielectric substrate with a biocompatible microfluidic channel aligned appropriately over the sensing area to enable consistent and intact sensing of the liquid samples. The CSSR-sensor is numerically modeled and compared in performance to the single-cell CSRR for detecting small variations in the dielectric properties. The sensitivity, reliability, and repeatability of the proposed sensor are practically demonstrated by the in-lab measurements for different liquid samples using a Vector Network Analyzer (VNA) setup where distinctive resonant features (amplitude and frequency) are extracted from multiple resonance modes in the reflection and transmission responses. A high sensitivity is also demonstrated for monitoring glucose level variations in synthetic blood samples of concentrations (70 – 150 mg/dL) which are clinically-relevant to diabetes conditions. Beside its impressive capability in detecting small dielectric variations, the developed sensor features other favorable attributes including compact size, simple fabrication, affordable cost, non-ionizing nature, and minimal health risk or impact. Such key advantages could potentially promote the proposed sensor for integration with other microwave components in an embedded device for non-invasive monitoring of blood glucose for diabetes.

29 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ARAmine Rabehi
Amine Rabehi
BGBenjamin Garlan
Benjamin Garlan
SAStefan Achtsnicht
Stefan Achtsnicht
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
AOAndreas Offenhäusser
Andreas Offenhäusser
HKHamid Reza Kokabi
Hamid Reza Kokabi
A magnetic frequency mixing technique with a set of miniaturized planar coils was investigated for use with a completely integrated Lab-on-Chip (LoC) pathogen sensing system. The system allows the detection and quantification of superparamagnetic beads. Additionally, in terms of magnetic nanoparticle characterization ability, the system can be used for immunoassays using the beads as markers. Analytical calculations and simulations for both excitation and pick-up coils are presented; the goal was to investigate the miniaturization of simple and cost-effective planar spiral coils. Following these calculations, a Printed Circuit Board (PCB) prototype was designed, manufactured, and tested for limit of detection, linear response, and validation of theoretical concepts. Using the magnetic frequency mixing technique, a limit of detection of 15 µg/mL of 20 nm core-sized nanoparticles was achieved without any shielding.

1 December 2018 in IRBM
Verified
Journal Article
Closed access
MTM. Tlili
M. Tlili
FDF. Deshours
F. Deshours
GAG. Alquié
G. Alquié
HKHamid Reza Kokabi
Hamid Reza Kokabi
SHS. Hardinata
S. Hardinata
FKF. Koskas
F. Koskas

2 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Chaouki HANNACHIChaouki HANNACHI
Chaouki HANNACHI
FDFrédérique Deshours
Frédérique Deshours
GAGeorge Alquie
George Alquie
HKHamid Reza Kokabi
Hamid Reza Kokabi
This paper examines the effect of finger fat pad thickness on the accuracy performance of complementary split-ring resonator (CSRR)-based microwave sensors for non-invasive blood glucose level detection. For this purpose, a simplified four-layer Cole–Cole model along with a CSRR-based microwave sensor have been comprehensively analyzed and validated through experimentation. Computed scattering parameter (S-parameter) responses to different fat layer thicknesses are employed to verify the concordance of the studied model with the measurement results. In this respect, a figure of merit (FM) based on the normalized squared difference is introduced to assess the accuracy of the considered Cole–Cole model. We have demonstrated that the analyzed model agrees closely with the experimental validation. In fact, the maximum error difference for all five fingertips does not exceed 1.73 dB over the entire frequency range of interest, from 1 GHz to 4 GHz.

20 October 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
BGBenjamin Garlan
Benjamin Garlan
ARAmine Rabehi
Amine Rabehi
KNKieu Ngo
Kieu Ngo
NSNeveu Sophie
Neveu Sophie
RMReza Askari Moghadam
Reza Askari Moghadam
HKHamid Reza Kokabi
Hamid Reza Kokabi
Rapid detection of a biological agent is essential to anticipate a threat to the protection of biodiversity and ecosystems. Our goal is to miniaturize a magnetic pathogen detection system in order to fabricate an efficient and portable system. The detection device is based on flat, multilayer coils associated with microfluidic structures to detect magnetic nanoparticles linked to pathogen agents. One type of immunological diagnosis is based on the measurement of the magnetic sensitivity of magnetic nanoparticles (MNPs), which are markers connected to pathogens. This method of analysis involves the coupling of antibodies or antigen proteins with MNPs. Among the available magnetic techniques, the frequency mixing method has a definite advantage by making it possible to quantify MNPs. An external magnetic field composed of a low- and a high-frequency field is applied to the sample reservoir. Then, the response signal is measured and analyzed. In this paper, magnetic microcoils are implemented on a multilayer Printed Circuit Board (PCB), and a microfluidics microstructure is designed in connection with the planar coils. Simulation software, COMSOL version 5.3, provides an analytical perspective to choose the number of turns in magnetic coils and to understand the effects of changing the shape and dimensions of the microfluidics microstructure.

19 December 2023 in JVS-Vascular Science
Verified
Journal Article
Open access
RSRania Shahbaz
Rania Shahbaz
ECEtienne Charpentier
Etienne Charpentier
MPMaharajah Ponnaiah
Maharajah Ponnaiah
FDFrédérique Deshours
Frédérique Deshours
HKHamid Reza Kokabi
Hamid Reza Kokabi
JDJean-Michel Davaine
Jean-Michel Davaine
Progress in best medical treatment have made identification of best candidates for carotid surgery more difficult. New diagnostic modalities could be helpful in this perspective. Microwaves (MWs) can quantify dielectric properties (complex relative permittivity) of biological tissues and MW technology has emerged as a promising field of research for distinguishing abnormal tissues from healthy ones. We here evaluated the ability of a dedicated MW sensor developed in our laboratory to identify vulnerable carotid lesions. We included 50 carotid lesions in this study. The plaques were analyzed and classified preoperatively by ultrasound (US) examination, computed tomography angiography and tested postoperatively using a MW sensor. Histopathological analysis was used as a gold standard to separate vulnerable plaques (VPs) from nonvulnerable plaques (NVPs). VPs were more frequently types 2 or 3 plaques (on US examination), had a greater proportion of low (<60 Hounsfield unit) and moderate (60-130 Hounsfield unit) attenuation components (computed tomography angiography) and displayed higher dielectric constant values (MW) than NVPs, which had an opposite profile. NVPs were more frequently asymptomatic plaques compared with VPs (P = .035). Multivariate analysis showed that US examination and MW identified VPs with a sensitivity of 77% and a specificity of 76% (cutoff value, -0.045; area under the curve, 0.848; P < .0001). We found that the presence of types 2 to 3 (on US examination) and high dielectric constant plaques in vitro was highly indicative of a VP based on histological analysis. Further studies are needed to determine the potential of MW to identify the most dangerous asymptomatic carotid lesions.