Kieu Ngo

Dr. Kieu Ngo


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2007 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
KNKieu Ngo
Kieu Ngo
PLPascal Lauque
Pascal Lauque
KAKhalifa Aguir
Khalifa Aguir

1 October 2007 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
SVStella Vallejos
Stella Vallejos
VKV. Khatko
V. Khatko
KAK. Aguir
K. Aguir
KNKieu Ngo
Kieu Ngo
JCJ. Calderer
J. Calderer
XCXavier Correig
Xavier Correig

1 July 2004 in Analytica Chimica Acta
Verified
Journal Article
Closed access
PLPascal Lauque
Pascal Lauque
MBMarc Bendahan
Marc Bendahan
JSJean-Luc Seguin
Jean-Luc Seguin
KNKieu Ngo
Kieu Ngo
Philippe KnauthPhilippe Knauth
Philippe Knauth

2 June 2019 in Corrosion
Verified
Journal Article
Closed access
FHFranã§Ois Huet
Franã§Ois Huet
KNKieu Ngo
Kieu Ngo
From the results of the three round-robin tests on electrochemical noise (EN) measurements with dummy cells performed between 2014 and 2017 by the European Cooperative Group on Corrosion Monitoring of Nuclear Materials, it was concluded that achieving valid EN measurements is jeopardized by a lack of theoretical knowledge as well as by software and hardware issues. This paper is aimed at guiding users of the EN technique by providing the minimum knowledge for EN measurements, including the necessary validation of the signals measured at different sampling frequencies by calculation of their power spectral densities. Two practical works performed with a commercial potentiostat are proposed. The first one is devoted to the measurement of the thermal noise of three resistors of equal value connected in a “star” arrangement and used in the conventional three-electrode EN measurement setup using a zero-resistance ammeter. This allows the instrumental noise of the equipment to be determined. The second practical work concerns pitting corrosion of two identical aluminum electrodes in potassium chloride to show that the noise impedance is equal to the modulus of the impedance of the electrodes, which is another way to validate the EN measurements. A bias voltage is then applied between the electrodes to obtain one anode and one cathode, which shows the difficulty of analyzing the measured EN in asymmetric systems.

1 January 2011 in Electrochimica Acta
Verified
Journal Article
Closed access
ATA.-T. Tran
A.-T. Tran
FHF. Huet
F. Huet
KNKieu Ngo
Kieu Ngo
PRP. Rousseau
P. Rousseau

29 May 2018 in Sensors
Verified
Journal Article
Open access
PDF file
ARAmine Rabehi
Amine Rabehi
BGBenjamin Garlan
Benjamin Garlan
SAStefan Achtsnicht
Stefan Achtsnicht
Hans-Joachim KrauseHans-Joachim Krause
Hans-Joachim Krause
AOAndreas Offenhäusser
Andreas Offenhäusser
HKHamid Reza Kokabi
Hamid Reza Kokabi
A magnetic frequency mixing technique with a set of miniaturized planar coils was investigated for use with a completely integrated Lab-on-Chip (LoC) pathogen sensing system. The system allows the detection and quantification of superparamagnetic beads. Additionally, in terms of magnetic nanoparticle characterization ability, the system can be used for immunoassays using the beads as markers. Analytical calculations and simulations for both excitation and pick-up coils are presented; the goal was to investigate the miniaturization of simple and cost-effective planar spiral coils. Following these calculations, a Printed Circuit Board (PCB) prototype was designed, manufactured, and tested for limit of detection, linear response, and validation of theoretical concepts. Using the magnetic frequency mixing technique, a limit of detection of 15 µg/mL of 20 nm core-sized nanoparticles was achieved without any shielding.