Samuel Dominguez-Amarillo

Prof. Samuel Dominguez-Amarillo

Instituto Universitario de Arquitectura y Ciencias de la Construcción, Escuela Técnica Superior de Arquitectura, Universidad de Sevilla
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Energy and Buildings
Verified
Journal Article
Open access
MSMarcel Schweiker
Marcel Schweiker
MAMaíra André
Maíra André
FAFarah Al-Atrash
Farah Al-Atrash
HAHanan Al-Khatri
Hanan Al-Khatri
RARea Risky Alprianti
Rea Risky Alprianti
ZZZahraSadat Zomorodian
ZahraSadat Zomorodian

Samuel Dominguez-AmarilloSamuel Dominguez-Amarillo
Samuel Dominguez-Amarillo
Jesica Fernández-AgüeraJesica Fernández-Agüera
Jesica Fernández-Agüera
SCSonia Cesteros-Garcia
Sonia Cesteros-Garcia
Roberto Alonso Gonzalez-LezcanoRoberto Alonso Gonzalez-Lezcano
Roberto Alonso Gonzalez-Lezcano
During the first outbreak of the SARS-CoV-2 pandemic the population, focusing primarily on the risk of infection, was generally inattentive to the quality of indoor air. Spain, and the city of Madrid in particular, were among the world’s coronavirus hotspots. The country’s entire population was subject to a 24/7 lockdown for 45 days. This paper describes a comparative longitudinal survey of air quality in four types of housing in the city of Madrid before and during lockdown. The paper analysed indoor temperatures and variations in CO2, 2.5 μm particulate matter (PM2.5) and total volatile organic compound (TVOC) concentrations before and during lockdown. The mean daily outdoor PM2.5 concentration declined from 11.04 µg/m3 before to 7.10 µg/m3 during lockdown. Before lockdown the NO2 concentration values scored as ‘very good’ 46% of the time, compared to 90.9% during that period. Although the city’s outdoor air quality improved, during lockdown the population’s exposure to indoor pollutants was generally more acute and prolonged. Due primarily to concern over domestic energy savings, the lack of suitable ventilation and more intensive use of cleaning products and disinfectants during the covid-19 crisis, indoor pollutant levels were typically higher than compatible with healthy environments. Mean daily PM2.5 concentration rose by approximately 12% and mean TVOC concentration by 37% to 559%. The paper also puts forward a series of recommendations to improve indoor domestic environments in future pandemics and spells out urgent action to be taken around indoor air quality (IAQ) in the event of total or partial quarantining to protect residents from respiratory ailments and concomitantly enhanced susceptibility to SARS-CoV-2, as identified by international medical research.

1 September 2019 in Energy and Buildings
Verified
Journal Article
Closed access
JFJesica Fernández-Agüera
Jesica Fernández-Agüera
Samuel Dominguez-AmarilloSamuel Dominguez-Amarillo
Samuel Dominguez-Amarillo
CACarmen Alonso
Carmen Alonso
FMFernando Martín-Consuegra
Fernando Martín-Consuegra

1 September 2016 in Energy and Buildings
Verified
Journal Article
Closed access
JFJesica Fernández-Agüera
Jesica Fernández-Agüera
Samuel Dominguez-AmarilloSamuel Dominguez-Amarillo
Samuel Dominguez-Amarillo
JSJuan Sendra
Juan Sendra
Rafael  SuárezRafael Suárez
Rafael Suárez

6 July 2012 in Energies
Verified
Journal Article
Open access
PDF file
Samuel Dominguez-AmarilloSamuel Dominguez-Amarillo
Samuel Dominguez-Amarillo
JSJuan Sendra
Juan Sendra
Angel Leon RodriguezAngel Leon Rodriguez
Angel Leon Rodriguez
Paula M. EsquiviasPaula M. Esquivias
Paula M. Esquivias
This work evaluates the potential for the reduction of energy demand in residential buildings by acting on the exterior envelope, both in newly constructed buildings and in the retrofitting of existing stock. It focuses on analysing social housing buildings in Mediterranean areas and on quantifying the scope of that reduction in the application of different envelope design strategies, with the purpose of prioritizing their application based on their energy efficiency. The analyses and quantifications were made by means of the generation of energy models with the TRNSYS tool for simple or combined solutions, identifying possible potentials for reduction of the energy demand from 20% to 25%, basically by acting on the windows. The case study was a newly built social housing building of a closed block type located in Seville (Spain). Its constructive techniques and the insulation level of its envelope are standardized for current buildings widespread across Mediterranean Europe.

26 November 2019 in Scientific Data
Verified
Journal Article
Open access
PDF file
MSMarcel Schweiker
Marcel Schweiker
AAAmar Abdul-Zahra
Amar Abdul-Zahra
MAMaíra André
Maíra André
FAFarah Al-Atrash
Farah Al-Atrash
HAHanan Al-Khatri
Hanan Al-Khatri
ZZZahra Sadat Zomorodian
Zahra Sadat Zomorodian
Thermal discomfort is one of the main triggers for occupants’ interactions with components of the built environment such as adjustments of thermostats and/or opening windows and strongly related to the energy use in buildings. Understanding causes for thermal (dis-)comfort is crucial for design and operation of any type of building. The assessment of human thermal perception through rating scales, for example in post-occupancy studies, has been applied for several decades; however, long-existing assumptions related to these rating scales had been questioned by several researchers. The aim of this study was to gain deeper knowledge on contextual influences on the interpretation of thermal perception scales and their verbal anchors by survey participants. A questionnaire was designed and consequently applied in 21 language versions. These surveys were conducted in 57 cities in 30 countries resulting in a dataset containing responses from 8225 participants. The database offers potential for further analysis in the areas of building design and operation, psycho-physical relationships between human perception and the built environment, and linguistic analyses.