Kevin Kawal

Mr. Kevin Kawal

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2023
Verified
Conference Paper
Closed access
KKKevin Kawal
Kevin Kawal
QHQiteng Hong
Qiteng Hong
PAPanagiotis
Panagiotis
NPN. Papadopoulos
N. Papadopoulos
SBSteven M. Blair
Steven M. Blair
CBCampbell D. Booth
Campbell D. Booth
Power systems with high penetrations of inverter-based resources are increasingly vulnerable to severe disturbances which may manifest as non-stationary voltage and current waveforms, presenting challenges to phasor measurement units which assume quasi-stationary conditions. Time synchronized, high-resolution, waveform measurements have emerged as a solution to accurately monitor emerging system dynamics. This paper proposes a synchronized waveform measurement unit algorithm to detect and characterize transient and dynamic phenomena present in synchronized waveform measurements. The proposed method utilizes the discrete wavelet packet transform to represent non-sinusoidal transients, while the adaptive empirical wavelet transform is applied to extract the fundamental and possible oscillation components. Finally, dynamic phasor extraction is performed via the Hilbert transform. The performance of the proposed algorithm is evaluated using synthetic test signals and compared to a phasor measurement unit algorithm using a goodness of fit metric. The results indicate that the proposed method produces an accurate and sparse representation of the underlying signal dynamics. The proposed method can potentially reduce communication requirements associated with high resolution synchronized waveform measurements, thus enabling real-time synchronized waveform-based applications.

30 September 2022
Verified
Book Chapter
Closed access
QHQiteng Hong
Qiteng Hong
KKKevin Kawal
Kevin Kawal
SPSubhadeep Paladhi
Subhadeep Paladhi
GZGuangxiao Zhang
Guangxiao Zhang
CBCampbell Booth
Campbell Booth
VTVladimir Terzija
Vladimir Terzija

5 February 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
Weijia YuanWeijia Yuan
Weijia Yuan
PCPavan Chaganti
Pavan Chaganti
QHQiteng Hong
Qiteng Hong
KKKevin Kawal
Kevin Kawal
MZMin Zhang
Min Zhang
NDNick Devine
Nick Devine
Achieving Net Zero requires a significant increase in electricity demand for transportation, heating, and industrial sectors. However, the increase in demand poses a challenge for heavily congested urban networks. High-Temperature Superconductor (HTS) 275 kV cables offer a credible technology solution that can uprate existing cable routes up to five times higher capacity density, utilizing existing 275 kV substations and removing the need to uprate circuits to 400 kV. This paper presents a detailed technical design and cost-benefit analysis for the cable installation. The technical analysis covers location selection, power system considerations, and standards alignment. A 12.9 km long 275 kV cable has been designed using cold dielectric and three separate phases. An equivalent circuit model was built using distance and differential protection methods to study the operation during different fault scenarios. A Standard mapping exercise has been performed to understand the gaps between the HTS and conventional cables by covering seven existing standards to identify the further tests to de-risk the technology. The economic analysis by considering the full lifecycle shows HTS is the economic for the chosen location with instances where substation equipment or land expansion costs are dominant.

10 May 2022 in IET Conference Proceedings
Verified
Journal Article
Closed access
KKKevin Kawal
Kevin Kawal
QHQ. Hong
Q. Hong
SPS. Paladhi
S. Paladhi
DLD. Liu
D. Liu
PPP. N. Papadopoulos
P. N. Papadopoulos
CBC. Booth
C. Booth
Line current differential (LCD) protection is traditionally considered to be highly dependable and secure. However, the increasing penetration of converter interfaced sources (CIS) (e.g. wind, PV, HVDC systems, etc.) could significantly reduce the system fault level and change the fault characteristics, thus presenting challenges to the reliable operation of LCD protection. In this paper, the impact of the integration of CIS on LCD performance is investigated comprehensively. Analytical expressions representing LCD relay operation in the presence of converter-driven fault currents and weak infeed conditions have been developed. A test network, comprising of a CIS model equipped with a typical converter fault-ride through strategy that is compliant with the GB Grid Code, has been built in a Real-Time Digital Simulator (RTDS). Simulations of LCD performance for different fault and system conditions are performed and presented. It is demonstrated that the dependability of the LCD relay can be compromised during internal phase-to-phase faults. The results also show that with the synchronous generation being displaced by CIS, the increasing CIS penetration and fault contribution from the CIS can lead to an increased phase angle difference between the fault currents contributed from the two ends of the protected line, which will increase the risk of the compromised protection performance.

8 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
KKKevin Kawal
Kevin Kawal
SBSteven Blair
Steven Blair
QHQiteng Hong
Qiteng Hong
PPPanagiotis Papadopoulos
Panagiotis Papadopoulos
Environmental concerns and economic constraints have led to increasing installations of mixed conductor circuits comprising underground cables (UGCs) and overhead transmission lines (OHLs). Faults on the OHL sections of such circuits are usually temporary, while there is a higher probability that faults on UGC sections are permanent. To maintain power system reliability and security, auto-reclose (AR) schemes are typically implemented to minimize outage duration after temporary OHL faults while blocking AR for UGC faults to prevent equipment damage. AR of a hybrid UCG–OHL transmission line, therefore, requires effective identification of the faulty section. However, the different electrical characteristics of UGC and OHL sections present significant challenges to existing protection and fault location methods. This paper presents a selective AR scheme for mixed conductor circuits based on the evaluation of differential currents in multiple defined protection zones, using distributed current transformer (CT) measurements provided by passive optical sensing. Case studies are conducted with a number of different UGC–OHL configurations, and the results demonstrate that the proposed scheme can accurately identify the faulty section, enabling effective selective AR of a comprehensive range of mixed conductor circuit topologies. The proposed scheme is also more cost effective, with reduced hardware requirements compared to conventional solutions. This paper thereby validates the optimal solution for mixed circuit protection as described in CIGRE Working Group B5.23 report 587.

6 February 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
PCPavan Chaganti
Pavan Chaganti
KKKevin Kawal
Kevin Kawal
QHQiteng Hong
Qiteng Hong
Weijia YuanWeijia Yuan
Weijia Yuan
MZMin Zhang
Min Zhang
SCSean Coleman
Sean Coleman
The global shift towards zero carbon emissions has led to an increased demand for electricity, (e.g., For electrification of heat, transportation, etc.). High-temperature superconductor (HTS) cables offer a high-capacity and small-footprint solution compared to traditional cable technologies, making them ideal for densely populated areas. HTS cables, however, possess different electrical characteristics compared to conventional cables. This paper presents a specific case study of a 12.9 km long 275 kV HTS cable connecting Birkenhead Substation and Lister Drive Substation in the U.K. A dynamic electrical model incorporating the varying resistance of the HTS cable was constructed. The HTS cable model was integrated into an equivalent test network, representing conditions at the target site, to analyse its behaviour and impact on conventional power system protection performance via simulation case studies. The results indicate that differential protection operates reliably, while distance protection is impacted by the varying resistance. However, the proposed HTS cable design at the specified location presents a relatively small change in HTS cable resistance. The impact on distance protection was therefore minimal and can be addressed by considering HTS properties when determining distance protection settings. The study was conducted by considering manufacturer-supplied HTS parameters, network parameters reflective of an actual location in the U.K. grid, and protection requirements specified in the U.K. grid code. The study provides valuable insights into practicality and protection strategies for reliable HTS cable operation in a real-world transmission network. The findings can inform future HTS cable designs and installations globally, as well as provide a framework for further research in this area.