Recently, nanowire detectors have been attracting increasing interest thanks to their advantages of high resolution and gain. The potential of using nanowire detectors is investigated in this work by developing a physically based model for Indium Phosphide (InP) phototransistor as well as by performing TCAD simulations. The model is based on solving the basic semiconductor equations for bipolar transistors and considering the effects of charge distribution on the bulk and on the surface. The developed model also takes into consideration the impact of surface traps, which are induced by photogenerated carriers situated at the surface of the nanowire. Further, photogating phenomena and photodoping are also included. Moreover, displacement damage (DD) is also investigated; an issue arises when the detector is exposed to repeated doses. The presented analytical model can predict the current produced from the incident X-ray beam at various energies. The calculation of the gain of the presented nanowire carefully considers the different governing effects at several values of energies as well as biasing voltage and doping. The proposed model is built in MATLAB, and the validity check of the model results is achieved using SILVACO TCAD device simulation. Comparisons between the proposed model results and SILVACO TCAD device simulation are provided and show good agreement.
19 October 2020 in IEEE Transactions on Electron Devices
In this article, a proposed 3-D cadmium telluride (CdTe) detector structure is presented and investigated. The electrical performance of the proposed structure is studied using 3-D TCAD simulations. The obtained results could be considered as a proof of concept for the feasibility of the performance of the presented detector under different operating conditions. For the proposed structure, the collection time is found to be about 1.3 ns at 15 V. The fast and hard response of the structure makes it suitable for high energy beams detection. The very low leakage current, which is about 16 pA at 16 V, allows the application of high bias voltages. Higher bias voltages (up to 16 V) may be required to decrease the proposed CdTe detector collection time without affecting its quality. Although the proposed detector structure is more appropriate to be biased at high voltages, these voltage values are still more less than those required in 2-D detectors. Based on this study, the proposed 3-D CdTe detector can be recommended for future high-energy physics and medical applications.