Vignesh K Manivasagam

Mr. Vignesh K Manivasagam

orcid
PhD Candidate, CSU

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2022 in Journal of Biomedical Materials Research Part A
Verified
Journal Article
Closed access
PDF file
VMVignesh K Manivasagam
Vignesh K Manivasagam
GPGopinath Perumal
Gopinath Perumal
HAHarpreet Singh Arora
Harpreet Singh Arora
Ketul C PopatKetul C Popat
Ketul C Popat

29 December 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
VMVignesh K Manivasagam
Vignesh K Manivasagam
Ketul C PopatKetul C Popat
Ketul C Popat
Blood-contacting titanium-based implants such as endovascular stents and heart valve casings are prone to blood clotting due to improper interactions at the surface level. In complement, the current clinical demand for cardiovascular implants is at a new apex. Hence, there is a crucial necessity to fabricate an implant with optimal mechanical properties and improved blood compatibility, while simultaneously interacting differentially with cells and other microbial agents. The present study intends to develop a superhydrophobic implant surface with the novel micro–nano topography, developed using a facile thermochemical process. The surface topography, apparent contact angle, and crystal structure are characterized on different surfaces. The hemo/blood compatibility on different surfaces is assessed by evaluating hemolysis, fibrinogen adsorption, cell adhesion and identification, thrombin generation, complement activation, and whole blood clotting kinetics. The results indicate that the super-hemo/hydrophobic micro–nano titanium surface improved hemocompatibility by significantly reducing fibrinogen adsorption, platelet adhesion, and leukocyte adhesion. Thus, the developed surface has high potential to be used as an implant. Further studies are directed towards analyzing the mechanisms causing the improved hemocompatibility of micro/nano surface features under dynamic in vitro and in vivo conditions.

2 May 2022 in In vitro models
Verified
Journal Article
Closed access
PDF file
VMVignesh K Manivasagam
Vignesh K Manivasagam
MSMagesh Sankar
Magesh Sankar
CGCaterina Bartomeu Garcia
Caterina Bartomeu Garcia
Jithin VishnuJithin Vishnu
Jithin Vishnu
KCKaushik Chatterjee
Kaushik Chatterjee
TWThomas Webster
Thomas Webster

15 October 2023 in Advanced Materials Interfaces
Verified
Journal Article
Open access
PKPrem Kantam
Prem Kantam
VMVignesh K Manivasagam
Vignesh K Manivasagam
TJTarun Kumar Jammu
Tarun Kumar Jammu
Roberta M. SabinoRoberta M. Sabino
Roberta M. Sabino
SVSravanthi Vallabhuneni
Sravanthi Vallabhuneni
Ketul C PopatKetul C Popat
Ketul C Popat
Slippery surfaces (i.e., surfaces that display high liquid droplet mobility) are receiving significant attention due to their biofluidic applications. Non‐textured, all‐solid, slippery hydrophilic (SLIC) surfaces are an emerging class of rare and counter‐intuitive surfaces. In this work, the interactions of blood and bacteria with SLIC surfaces are investigated. The SLIC surfaces demonstrate significantly lower platelet and leukocyte adhesion (≈97.2% decrease in surface coverage), and correspondingly low platelet activation, as well as significantly lower bacterial adhesion (≈99.7% decrease in surface coverage of live Escherichia Coli and ≈99.6% decrease in surface coverage of live Staphylococcus Aureus) and proliferation compared to untreated silicon substrates, indicating their potential for practical biomedical applications. The study envisions that the SLIC surfaces will pave the path to improved biomedical devices with favorable blood and bacteria interactions.

1 June 2022 in In vitro models
Verified
Journal Article
Closed access
PDF file
ABAbhishek Bhattacharjee
Abhishek Bhattacharjee
Roberta M. SabinoRoberta M. Sabino
Roberta M. Sabino
JGJustin Gangwish
Justin Gangwish
VMVignesh K Manivasagam
Vignesh K Manivasagam
SJSusan James
Susan James
Yan LiYan Li
Yan Li

1 June 2024 in In vitro models
Verified
Journal Article
Open access
PDF file
VMVignesh K Manivasagam
Vignesh K Manivasagam
Ketul C PopatKetul C Popat
Ketul C Popat
Cardiovascular diseases (CVDs) remain the leading cause of death worldwide, and the most common form is coronary artery disease (CAD). Treatment options include coronary artery bypass surgery (CABG) or percutaneous heart intervention (PCI), but both have drawbacks. Bare metal stents (BMS) are commonly used to treat CAD; however, they lead to restenosis. Drug-eluting stents (DES) were developed to overcome this limitation; however, they lead to late thrombosis. Hence, there is an urgent need to engineer stent surfaces that selectively prevents smooth muscle cell adhesion and proliferation (restenosis), while promoting endothelial cell adhesion and differentiation (endothelialization), thus enhancing hemocompatibility. In this study, hydrothermal treatment with either sodium hydroxide or sulfuric acid was used to modify the surface of titanium. Titanium surface treated with sulfuric acid led to a micro-nano-surface morphology that selectively promoted endothelial cell adhesion and differentiation while prevented smooth muscle cell proliferation.